Operative Time and Other Outcomes of the Electrothermal Bipolar Vessel Sealing System (LigaSure™) Versus Other Methods for Surgical Hemostasis: A Meta-Analysis

被引:71
|
作者
Macario, Alex [1 ,2 ]
Dexter, Franklin [3 ,4 ]
Sypal, Jennifer [5 ]
Cosgriff, Ned [5 ]
Heniford, B. Todd [6 ]
机构
[1] Stanford Univ, Sch Med, Dept Anesthesia, Stanford, CA 94305 USA
[2] Stanford Univ, Sch Med, Dept Hlth Res & Policy, Stanford, CA 94305 USA
[3] Univ Iowa, Dept Anesthesia, Iowa City, IA 52242 USA
[4] Univ Iowa, Dept Hlth Policy & Management, Iowa City, IA 52242 USA
[5] Energy Based Devices, Covidien, Boulder, CO USA
[6] Carolinas Med Ctr, Div Gastrointestinal & Minimally Invas Surg, Charlotte, NC 28203 USA
关键词
operative time; surgical hemostasis; blood loss; pain scores; complications; electrothermal bipolar vessel sealing system;
D O I
10.1177/1553350608324933
中图分类号
R61 [外科手术学];
学科分类号
摘要
A meta-analysis was performed of 29 prospective, randomized trials (published January 1, 2000, to August 14, 2007) comparing an electrothermal bipolar vessel sealing system (EBVS-LigaSure (TM), Covidien) (total n = 1107 patients) with either clamping with suture ligation/electrocauterization (n = 1079 patients) or ultrasonic energy (eg, Harmonic Scalpel (R), Johnson & Johnson). Hemorrhoidectomy (12 articles), hysterectomy (4 articles), and thyroidectomy (3 articles) were the most common procedures. For 15 of 26 studies reporting standard deviations, the normalized mean operative time reduction for EBVS equaled 28% (95% confidence interval [CI] 18%-39%, P < .0001) compared with conventional surgical hemostasis. Operative time was reduced with EBVS in 24 of 26 studies (P < .0001). EBVS was associated with 43 mL (95% CI 14-73 mL, P = .0021) less blood loss, fewer complications (odds ratio 0.66, 95% CI 0.47-0.92, P = .02), and mean reduction in postoperative pain of 2.8 units (95% CI 1.5-4.1, P < .0001). Five studies used ultrasonic energy as the comparator, but none reported standard deviation so data could not be pooled.
引用
收藏
页码:284 / 291
页数:8
相关论文
共 50 条
  • [1] Effectiveness of electrothermal bipolar vessel-sealing devices versus other electrothermal and ultrasonic devices for abdominal surgical hemostasis: a systematic review
    Janssen, Petra F.
    Brolmann, Hans A. M.
    Huirne, Judith A. F.
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2012, 26 (10): : 2892 - 2901
  • [2] Effectiveness of electrothermal bipolar vessel-sealing devices versus other electrothermal and ultrasonic devices for abdominal surgical hemostasis: a systematic review
    Petra F. Janssen
    Hans A. M. Brölmann
    Judith A. F. Huirne
    Surgical Endoscopy, 2012, 26 : 2892 - 2901
  • [3] Electrothermal bipolar vessel sealing system (LigaSure™) for hemostasis during thyroid surgery: A comprehensive review
    Wiseman, S.M. (smwiseman@providencehealth.bc.ca), 1600, Expert Reviews Ltd. (10):
  • [4] Electrothermal bipolar vessel sealing system (LigaSure T) for hemostasis during thyroid surgery: a comprehensive review
    Butskiy, Oleksandr
    Wiseman, Sam M.
    EXPERT REVIEW OF MEDICAL DEVICES, 2013, 10 (03) : 389 - 410
  • [5] Electrothermal bipolar vessel sealing device (LigaSure™) versus conventional diathermy in laparoscopic myomectomy: A propensity-matched analysis
    Li, Yi-Chieh
    Chao, Angel
    Yang, Lan-Yang
    Huang, Hui-Yu
    Huang, Yi-Ting
    Kuo, Hsin-Hong
    Wang, Chin-Jung
    PLOS ONE, 2018, 13 (03):
  • [6] Ceftriaxone versus Other Antibiotics for Surgical ProphylaxisA Meta-Analysis
    Silvano Esposito
    Silvana Noviello
    Alessandro Vanasia
    Paola Venturino
    Clinical Drug Investigation, 2004, 24 : 29 - 39
  • [7] Ceftriaxone versus other anitbiotics for surgical prophylaxis - A meta-analysis
    Esposito, S
    Noviello, S
    Vanasia, A
    Venturino, P
    CLINICAL DRUG INVESTIGATION, 2004, 24 (01) : 29 - 39
  • [8] Hemostasis in thyroid surgery: Harmonic scalpel versus other techniques-a meta-analysis
    Ecker, Thomas
    Carvalho, Andre Lopes
    Choe, Jun-Ho
    Walosek, Gudrun
    Preuss, Klaus Juergen
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2010, 143 (01) : 17 - 25
  • [9] Adjustable slings versus other surgical methods in female stress urinary incontinence: a systematic review and meta-analysis
    Grigoryan, Bagrat
    Shadyan, Gor
    Kasyan, George
    Pushkar, Dmitry
    INTERNATIONAL UROGYNECOLOGY JOURNAL, 2023, 34 (07) : 1351 - 1367
  • [10] Adjustable slings versus other surgical methods in female stress urinary incontinence: a systematic review and meta-analysis
    Bagrat Grigoryan
    Gor Shadyan
    George Kasyan
    Dmitry Pushkar
    International Urogynecology Journal, 2023, 34 : 1351 - 1367