Rescue of failing or failed trabeculectomy blebs with slit-lamp needling and adjunctive mitomycin C in Indian eyes

被引:12
|
作者
Pathak-Ray, Vanita [1 ]
Choudhari, Nikhil [2 ]
机构
[1] Ctr Sight, Rd 2,Banjara Hills, Hyderabad 500034, Telangana, India
[2] LV Prasad Eye Inst, VST Ctr Glaucoma, Hyderabad, Telangana, India
关键词
Failed blebs; mitomycin C; needling; slit-lamp needling; FOLLOW-UP; 5-FLUOROURACIL; REVISION; OUTCOMES; EFFICACY;
D O I
10.4103/ijo.IJO_523_17
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The aim of this study is to investigate the efficacy and safety of needling-revision augmented with a high dose of mitomycin C (MMC) in failing or failed blebs after trabeculectomy in Indian eyes. Methods: Prospective, noncomparative, interventional study. All patients (>18 years) who had raised intraocular pressure (IOP) following trabeculectomy (>6 weeks and <2 years), who had a flat bleb, bleb encapsulation, and/or required antiglaucoma medication (AGM) for IOP control were eligible for inclusion. MMC was injected subconjunctivally at least <1/2> hour before the needling procedure was carried out at the slit lamp in the outpatient's clinic. Results: Thirty-nine eyes of 38 patients were included. The median follow-up was 20 months and time interval between trabeculectomy and needle revision was 113 days. Initially, in all cases, aqueous flow was re-established with a raised bleb; 7 eyes required repeat needling. IOP decreased from median 24 mmHg (Q1 21, Q3 27, interquartile range [IQR] 6, range 18-35) preneedling to median 14 mmHg (Q1 10, Q3 16, IQR 6, range 6-18) postneedling at last follow-up (P < 0.0001, 95% confidence interval [CI]: 8.2-13.0). The use of AGM reduced from median 1 (Q1 0, Q3 3, IQR 3, range 0-4) preneedling to median 0 postneedling (P < 0.0001, 95% CI: 1-2). Complete success was seen in 28 eyes (71.8%, 95% CI: 71.1%-96.4%); another 5 eyes (12.8%) were controlled with AGM (qualified success) with overall success of 84.6%. Most complications were transient in nature with resolution within 1 week. One patient developed hypotony, and another developed a late bleb leak. Conclusion: Needling revision augmented with high-dose MMC, at the slit lamp, effectively rescues failing or failed filtration, and appears to be safe.
引用
收藏
页码:71 / 76
页数:6
相关论文
共 30 条
  • [1] Slit-lamp needle revision of failed filtering blebs using mitomycin C
    Mardelli, PG
    Lederer, CM
    Murray, PL
    Pastor, SA
    Hassanein, KM
    [J]. OPHTHALMOLOGY, 1996, 103 (11) : 1946 - 1955
  • [2] Slit-lamp needle revision of failed filtering blebs using mitomycin C - Discussion
    Migliazzo, CV
    [J]. OPHTHALMOLOGY, 1996, 103 (11) : 1955 - 1955
  • [3] Office-based Slit-lamp Needle Revision with Adjunctive Mitomycin-C for Late Failed or Encapsulated Filtering Blebs
    Amini, Heidar
    Esmaili, Alireza
    Zarei, Reza
    Amini, Nima
    Daneshvar, Ramin
    [J]. MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2012, 19 (02) : 216 - 221
  • [4] Antimetabolite augmented slit-lamp needling for the management of post-trabeculectomy failing bleb
    Romo Sainz, Montserrat
    Paczka, Jose A.
    Dorantes Diez, Yesenia Yolanda
    Giorgi Sandoval, Luz America
    Gonzalez Lomeli, Monica Montserrat M.
    Aguilera Ruiz, Karla J.
    Orozco Garcia, Andrea
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [5] Slit-lamp needle revision of failed filtering blebs using high-dose mitomycin C
    Shetty, RK
    Wartluft, L
    Moster, MR
    [J]. JOURNAL OF GLAUCOMA, 2005, 14 (01) : 52 - 56
  • [6] Bleb Needling with Mitomycin C as Adjunctive Therapy in Failing Blebs: A Retrospective Study
    Del Noce, Chiara
    Vagge, Aldo
    Traverso, Carlo Enrico
    [J]. OPHTHALMIC RESEARCH, 2019, 62 (01) : 55 - 60
  • [7] Treatment of Encapsulated Blebs with Slit-Lamp Needling and Subconjunctival Interferon Injection
    Zhen MaoXing LiuYimin ZhongDan CaoMei LiFenfen Yu State Key Laboratory on OphthalmologyZhongshan Ophthalmic CenterSun Yatsen UniversityGuangzhou China
    [J]. Eye Science., 2011, 26 (03) - 142
  • [9] Post-operative needling of failing trabeculectomy blebs with adjunctive 5-fluorouracil
    Broadway, DC
    Bloom, PA
    Hitchings, RA
    Khaw, PT
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 1137 - 1137
  • [10] Comparison of a Remote Operating Slit-Lamp Microscope System With a Conventional Slit-Lamp Microscope System for Examination of Trabeculectomy Eyes
    Kashiwagi, Kenji
    Tanabe, Naohiko
    Go, Kentaro
    Imasawa, Mitsuhiro
    Mabuchi, Fumihiko
    Chiba, Tetsuya
    Sugiyama, Atsushi
    Abe, Keitetsu
    [J]. JOURNAL OF GLAUCOMA, 2013, 22 (04) : 278 - 283