Interventional Radiology at a Single Institution over 9 Years: A Comprehensive Evaluation of Procedures and an Estimation of Collective Effective Dose

被引:13
|
作者
Cornetto, Andrea Peruzzo [1 ]
Pasquino, Massimo [3 ]
Aimonetto, Stefania [1 ]
Zenone, Flora [1 ]
Catuzzo, Paola [1 ]
Natrella, Massimiliano [2 ]
Cristoferi, Massimo [2 ]
Fanelli, Gianluca [2 ]
Tofani, Santi [1 ]
Meloni, Teodoro [2 ]
机构
[1] U Parini Reg Hosp, AUSL Locali Valle Aosta, Dept Med Phys, I-11100 Aosta, AO, Italy
[2] U Parini Reg Hosp, AUSL Locali Valle Aosta, Diagnost & Intervent Radiol Dept, I-11100 Aosta, AO, Italy
[3] Ivrea Hosp, Azienda Sanit Locale Piemonte TO4, Dept Med Phys, Ivrea, Italy
关键词
RAD-IR; AREA PRODUCT; AOSTA VALLEY; RADIATION; POPULATION; GUIDELINES; EXPOSURE;
D O I
10.1016/j.jvir.2012.08.027
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the exposure parameters, effective dose, frequency, and collective dose for interventional radiology (IR) procedures performed at a single institution during a 9-year period. Materials and Methods: According to the anatomic region imaged, seven diagnostic and 16 therapeutic IR procedures performed between 2002 and 2010 were retrospectively investigated with regard to exposure setting parameters and frequency. Dose-area products (DAPs), cumulative doses (CDs), and irradiation time values were analyzed on a sample of 1,100 examinations. DAP distributions (median, mean, and percentiles) were adjunctively determined by using bootstrap resampling in PCXMC software to estimate patient effective dose. Data provided by the Radiological Information System allowed collective effective and per-capita doses to obtained. Results: The exposure parameters showed widespread variability. The median DAP values for pelvic arteriography and pelvic arterial angioplasty/stent placement were 10,015 and 19,424 cGy.cm(2), respectively. For the 23 procedures studied, the estimated average per-procedure effective dose ranged from 0.34 to 104.9 mSv. The pelvis (37%) was the region most often imaged in diagnostic procedures, and angioplasty/stent treatment of vessels was the most frequently performed therapeutic procedure (44%). During the study period, IR procedures increased in frequency (+137%), with a consequent increase in the per-capita dose (0.172 to 0.461 mSv) and collective dose (21 to 58 man-Sv/y). Conclusions: A comprehensive Monte Carlo-aided analysis, which allowed evaluation of contributions in terms of per-procedure and collective doses to the population for the practice of IR, showed a significant growth rate during the study period.
引用
收藏
页码:1665 / 1675
页数:11
相关论文
共 40 条
  • [1] Effective-dose estimation in interventional radiological procedures
    Falco M.D.
    Masala S.
    Stefanini M.
    Bagalà P.
    Morosetti D.
    Calabria E.
    Tonnetti A.
    Verona-Rinati G.
    Radiological Physics and Technology, 2018, 11 (2) : 149 - 155
  • [2] Dose Evaluation in Medical Staff during Interventional Radiology Procedures
    Bacchim Neto, F. A.
    Alves, A. F. F.
    Alvarez, M.
    Rosa, M. E. D.
    Macedo de Freitas, C. C.
    Moura, R.
    Pina, D. R.
    Miranda, J. R. A.
    VI LATIN AMERICAN CONGRESS ON BIOMEDICAL ENGINEERING (CLAIB 2014), 2014, 49 : 927 - 930
  • [3] Calculation of conversion factors for effective dose for various interventional radiology procedures
    Compagnone, Gaetano
    Giampalma, Emanuela
    Domenichelli, Sara
    Renzulli, Matteo
    Golfieri, Rita
    MEDICAL PHYSICS, 2012, 39 (05) : 2491 - 2498
  • [4] Estimation of effective dose in some digital angiographic and interventional procedures
    Cruces, RR
    García-Granados, J
    Romero, FJD
    Armas, JH
    BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (841): : 42 - 47
  • [5] Overview of double dosimetry procedures for the determination of the effective dose to the interventional radiology staff
    Jarvinen, H.
    Buls, N.
    Clerinx, P.
    Jansen, J.
    Miljanic, S.
    Nikodemova, D.
    Ranogajec-Komor, M.
    d'Errico, F.
    RADIATION PROTECTION DOSIMETRY, 2008, 129 (1-3) : 333 - 339
  • [6] Comparison of four analogues of radiation dose for estimation of skin dose during interventional radiology procedures
    Fletcher, DW
    Miller, DM
    Balter, S
    Taylor, MA
    RADIOLOGY, 2000, 217 : 403 - 404
  • [7] Advancing patient safety in interventional radiology: effective dose evaluation and LDRL
    Alvarez, M.
    Guassu, R. A. C.
    Rosa, A. A.
    de Sousa, R. R.
    de Pina, D. R.
    RADIOPROTECTION, 2025, 60 (01) : 28 - 36
  • [8] Simulation of Hp(10) and effective dose received by the medical staff in interventional radiology procedures
    Ferrari, P.
    Becker, F.
    Jovanovic, Z.
    Khan, S.
    Bakhanova, E.
    Principi, S.
    Kristic, D.
    Pierotti, L.
    Mariotti, F.
    Faj, D.
    Turk, T.
    Nikezic, D.
    Bertolini, M.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2019, 39 (03) : 809 - 824
  • [9] EXPERIMENTAL VALIDATION OF ALGORITHMS USED TO ESTIMATE EFFECTIVE DOSE DURING INTERVENTIONAL RADIOLOGY PROCEDURES
    Negri, P.
    Campi, F.
    De Crescenzo, S.
    Garlati, L.
    Tambussi, O.
    RADIATION PROTECTION DOSIMETRY, 2019, 187 (01) : 42 - 49
  • [10] Contemporary Interventional Radiology Dosimetry: Analysis of 4,784 Discrete Procedures at a Single Institution
    Bundy, Jacob J.
    Chick, Jeffrey Forris Beecham
    Hage, Anthony N.
    Gemmete, Joseph J.
    Srinivasa, Rajiv N.
    Johnson, Evan J.
    Christodoulou, Emmanuel
    Srinivasa, Ravi N.
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2018, 15 (09) : 1214 - 1221