Survey of contrasts of polymers under a high-contrast X-ray computerized tomography

被引:11
|
作者
Nishikawa, Yukihiro [1 ]
Hatanaka, Yusuke [1 ]
Iizuka, Shungo [1 ]
Takahashi, Masaoki [1 ]
机构
[1] Kyoto Inst Technol, Dept Macromol Sci & Engn, Sakyo Ku, Kyoto 6068585, Japan
关键词
X-ray computerized tomography; Polymer blends; Three-dimensional imaging; BICONTINUOUS STRUCTURE; MIXTURE;
D O I
10.1016/j.polymer.2012.07.040
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Contrasts of the polymer materials under a high contrast X-ray computerized tomography (XCT) are comprehensively investigated. We developed a high contrast XCT, and demonstrated its capabilities to polymer systems, such as polymer blends. Then we got a hypothesis that the pixel values of the cross-sectional image obtained by XCT agree with the X-ray absorption coefficient at 15 keV. This hypothesis is intensively examined by using various polymers. Consequently, we propose an empirical criterion that 0.1 cm(-1) difference in the X-ray absorption coefficients at 15 keV is necessary to distinguish the polymers under XCT. This criterion is also confirmed in the polymer blend systems. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:4287 / 4292
页数:6
相关论文
共 50 条
  • [1] High-contrast x-ray microtomography in dental research
    Davis, Graham
    Mills, David
    DEVELOPMENTS IN X-RAY TOMOGRAPHY XI, 2017, 10391
  • [2] COMPUTERIZED X-RAY TOMOGRAPHY
    HILL, KR
    JOYNER, RW
    SCIENCE PROGRESS, 1975, 62 (246) : 237 - 262
  • [3] In-line X-ray phase-contrast computerized tomography
    National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029, China
    Guangxue Xuebao, 2008, 3 (609-612):
  • [4] X-RAY COMPUTERIZED-TOMOGRAPHY
    WELLINGTON, SL
    VINEGAR, HJ
    JOURNAL OF PETROLEUM TECHNOLOGY, 1987, 39 (08): : 885 - 898
  • [5] X-RAY COMPUTERIZED TOMOGRAPHY.
    Wellington, S.L.
    Vinegar, H.J.
    1600, (39):
  • [6] PROGRESS IN COMPUTERIZED X-RAY TOMOGRAPHY
    KRUMME, HJ
    BAR, A
    KERNTECHNIK, 1989, 53 (04) : 260 - 264
  • [7] DIFFERENTIAL X-RAY ABSORPTIOMETRY APPLIED TO COMPUTERIZED X-RAY TOMOGRAPHY
    FRYAR, J
    MCCARTHY, KJ
    FENELON, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 259 (03): : 557 - 565
  • [8] Collimation principles of a hollow X-ray microbeam for high-contrast cytoplasm irradiation
    Cheng, Qinqin
    Zhao, Ruifeng
    Wang, Xiaowa
    Wang, Xufei
    JOURNAL OF RADIATION RESEARCH, 2024, 65 (05) : 591 - 602
  • [9] High-contrast pixels: a new feature for defect detection in X-ray testing
    Mery, D.
    INSIGHT, 2006, 48 (12) : 751 - 753
  • [10] Estimating X-ray instability in computerized tomography
    Reznikov, B.S.
    Rader, E.I.
    Zagnibeda, I.G.
    Biomedical Engineering, 1989, 23 (02) : 51 - 54