Defining the Influence Region in neighborhood-scale CFD simulations for natural ventilation design

被引:118
|
作者
Tong, Zheming
Chen, Yujiao
Malkawi, Ali
机构
[1] Harvard Univ, Ctr Green Bldg & Cities, Cambridge, MA 02138 USA
[2] Harvard Univ, Grad Sch Design, Cambridge, MA 02138 USA
关键词
Natural ventilation; Influence Region; Street canyon; Air change rate (ACH); CFD; AIR-QUALITY; WIND-TUNNEL; MEAN FLOW; DISPLACEMENT VENTILATION; OPERATION OPTIMIZATION; POLLUTANT DISPERSION; CROSS-VENTILATION; HIGH-RESOLUTION; TURBULENT-FLOW; STREET CANYON;
D O I
10.1016/j.apenergy.2016.08.098
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Natural ventilation is one of the most important design options for green buildings, which reduces energy use and improves thermal comfort. Computational Fluid Dynamics (CFD) simulations have been used increasingly for natural ventilation design in urban neighborhoods. The accuracy of such simulations relies largely on how the CFD domain is chosen. In the domain, we define the Influence Region as the area where the surrounding buildings must be modeled explicitly to predict the ventilation flow rate accurately. This study presents the early efforts to determine the adequate size of the Influence Region in the CFD domain using a coupled indoor-outdoor CFD simulation, in which the air change rate (ACH) no longer varies noticeably with increasing number of surrounding obstacles. Convergence charts of ACH as a function of an increasing number of surrounding building layers are generated using various urban parameters (e.g., wind condition, aspect ratio, building height relative to surroundings, downstream obstacles, and non-idealized surroundings). Our analysis demonstrated that only including the adjacent layer of surrounding obstacles is not sufficient for predicting correctly the ACH because of the artificial channeling effect between buildings. For both normal and oblique wind directions, three layers of surroundings are required for regular street canyons with an aspect ratio H/W = 1. In the case of wide canyons (H/W = 1/3), two layers of surroundings are needed because there is less flow interference between upstream and downstream obstacles. For the urban configuration, where the target building is significantly taller than nearby structures, the ACH on higher floors does not vary much with increasing amount of surroundings, which significantly reduces the required number of buildings in the Influence Region. In addition, buildings at the side and downstream of the target building can be moderately excluded in the Influence Region as long as the most adjacent downstream layer of obstacles is modeled. A real urban configuration with non-uniform spacing among buildings is evaluated. We showed that the required size of the Influence Region that is derived from uniform building arrays still generally applies to non-idealized landscapes. This study demonstrates the importance of assessing the sensitivity of the selected Influence Region in CFD simulations to reduce unintended modeling errors and computing expense. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:625 / 633
页数:9
相关论文
共 50 条
  • [1] Evaluation of satellite-derived building height extraction by CFD simulations: A case study of neighborhood-scale ventilation in Hong Kong
    Wang, Weiwen
    Xu, Yong
    Ng, Edward
    Raasch, Siegfried
    [J]. LANDSCAPE AND URBAN PLANNING, 2018, 170 : 90 - 102
  • [2] Unsteady CFD simulations for natural ventilation
    Wright, Nigel G.
    Hargreaves, David M.
    [J]. International Journal of Ventilation, 2006, 5 (01) : 13 - 20
  • [3] Natural ventilation design using CFD
    Wark, Christopher
    [J]. PROCEEDINGS OF THE ENERGY SUSTAINABILITY CONFERENCE 2007, 2007, : 581 - 595
  • [4] INTEGRATION OF CFD SIMULATIONS IN COMPUATIONAL DESIGN FOR HARNESSING THE NATURAL VENTILATION PERFORMANCE OF TYPICAL ATRIUM SPACES IN ATHENS, GREECE
    Chronis, Angelos
    Stefopoulou, Foteini
    Liapi, Katherine
    [J]. 2018 BUILDING PERFORMANCE ANALYSIS CONFERENCE AND SIMBUILD, 2018, : 331 - 337
  • [5] Application of CFD Tools to Optimize Natural Building Ventilation Design
    Teixeira, Jose Carlos
    Lomba, Ricardo
    Teixeira, Senhorinha F. C. F.
    Lobarinhas, Pedro
    [J]. COMPUTATIONAL SCIENCE AND ITS APPLICATIONS - ICCSA 2012, PT III, 2012, 7335 : 202 - 216
  • [6] Design of the natural ventilation system for the fishing vessel by the CFD methods
    Sugalski, Karol
    [J]. SCIENTIFIC JOURNALS OF THE MARITIME UNIVERSITY OF SZCZECIN-ZESZYTY NAUKOWE AKADEMII MORSKIEJ W SZCZECINIE, 2014, 40 (112): : 23 - 26
  • [7] Framework for integrated multi-scale computational fluid dynamics simulations in natural ventilation design
    Kalua, Amos
    Jones, James
    Battaglia, Francine
    Grant, Elizabeth
    [J]. BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2024, : 733 - 753
  • [8] Effect of ventilator size on natural ventilation in parral greenhouse by means of CFD simulations
    Baeza, EJ
    Pérez-Parra, J
    Montero, JI
    [J]. PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON SUSTAINABLE GREENHOUSE SYSTEMS, VOLS 1 AND 2, 2005, (691): : 465 - 472
  • [9] Efficacy of greenhouse natural ventilation: Environmental monitoring and CFD simulations of a study case
    Benni, Stefano
    Tassinari, Patrizia
    Bonora, Filippo
    Barbaresi, Alberto
    Torreggiani, Daniele
    [J]. ENERGY AND BUILDINGS, 2016, 125 : 276 - 286
  • [10] CFD Simulations of Cross Natural Ventilation through an Apartment with Modified Inflow Boundary Conditions
    Liu, Sumei
    Pan, Wuxuan
    Lin, Xiaorui
    Qing, Ke
    Zhang, Weizhen
    Long, Zhengwei
    Chen, Qingyan
    [J]. PROCEEDINGS OF BUILDING SIMULATION 2019: 16TH CONFERENCE OF IBPSA, 2020, : 3794 - 3801