Comparison of 18F-Labeled Fluoroalkylphosphonium Cations with 13N-NH3 for PET Myocardial Perfusion Imaging

被引:19
|
作者
Kim, Dong-Yeon [1 ]
Kim, Hyeon Sik [1 ]
Reder, Sybille [2 ]
Zheng, Jin Hai [1 ]
Herz, Michael [2 ]
Higuchi, Takahiro [2 ]
Pyo, AYoung [1 ]
Bom, Hee-Seung [1 ]
Schwaiger, Markus [2 ]
Min, Jung-Joon [1 ]
机构
[1] Chonnam Natl Univ, Hwasun Hosp, Dept Nucl Med, Hwasun 519763, Jeonnam, South Korea
[2] Tech Univ Munich, Klinikum Rechts Isar, Dept Nucl Med, D-80290 Munich, Germany
关键词
F-18-fluoroalkylphosphonium cations; perfusion; first-pass extraction fraction; cardiac PET; myocardial infarction; POSITRON-EMISSION-TOMOGRAPHY; F-18-FLUOROBENZYL TRIPHENYL PHOSPHONIUM; POTENTIAL AGENT; TRIPHENYLPHOSPHONIUM CATION; INFARCTION MODEL; MEMBRANE; HEART; TRACER; N-13-AMMONIA; ACCURACY;
D O I
10.2967/jnumed.115.156794
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Despite substantial advances in the diagnosis of cardiovascular disease, there is a need for F-18-labeled myocardial perfusion agents for the diagnosis of ischemic heart disease because current PET tracers for myocardial perfusion imaging have a short half-life that limits their widespread clinical use in PET. Thus, F-18-labeled fluoroalkylphosphonium derivatives (F-18-FATPs), including (5-F-18-fluoropentyl)triphenylphosphonium cation (F-18-FPTP), (6-F-18-fluorohexyl)triphenylphosphonium cation (F-18-FHTP), and (2-(2-F-18-fluoroethoxy)ethyl)triphenylphosphonium cation (F-18-FETP), were synthesized. The myocardial extraction and image quality of the F-18-FATPs were compared with those of N-13-NH3 in rat models. Methods: The first-pass extraction fraction (EF) values of the F-18-FATPs (F-18-FPTP, F-18-FHTP, F-18-FETP) and N-13-NH3 were measured in isolated rat hearts perfused with the Langendorff method (flow velocities, 0.5, 4.0, 8.0, and 16.0 mUmin). Normal and myocardial infarction rats were imaged with small-animal PET after intravenous injection of 37 MBq of F-18-FATPs and N-13-NH3. To determine pharmacokinetics, a region of interest was drawn around the heart, and time activity curves of the F-18-FATPs and N-13-NH3 were generated to obtain the counts per pixel per second. Defect size was analyzed on the basis of polar map images of F-18-FATP5 and N-13-NH3 Results: The EF values of F-18-FATPs and N-13-NH3 were comparable at low flow velocity (0.5 mUmin), whereas at higher flows EF values of F-18-FATPs were significantly higher than those of N-13-NH3 (4.0, 8.0, and 16.0 mUmin, P < 0.05). Myocardium-to-liver ratios of F-18-FPTP, F-18-FHTP, F-18-FETP, and N-13-NH3 were 2.10 +/- 0.30, 4.36 +/- 0.20, 3.88 +/- 1.03, and 0.70 +/- 0.09, respectively, 10 min after injection, whereas myocardium-to-lung ratios were 5.00 +/- 0.25, 4.33 +/- 0.20, 7.98 +/- 1.23, and 2.26 +/- 0.14, respectively. Although F-18-FATPs and N-13-NH3 sharply delineated myocardial perfusion defects, defect size on the N-13-NH3 images was significantly smaller than on the F-18-FATP images soon after tracer injection (0-10 min, P = 0.027). Conclusion: F-18-FATPs exhibit higher EF values and more rapid clearance from the liver and lung than N-13-NH3 in normal rats, which led to excellent image quality in a rat model of coronary occlusion. Therefore, F-18-FATPs are promising new PET radiopharmaceuticals for myocardial perfusion imaging.
引用
收藏
页码:1581 / 1586
页数:6
相关论文
共 50 条
  • [1] Promising New 18F-Labeled Tracers for PET Myocardial Perfusion Imaging
    Brunken, Richard C.
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (10) : 1478 - 1479
  • [2] Quantitative myocardial perfusion imaging for the assessment of myocardial regeneration therapy: 13N-NH3 PET in the myocardial infarction model of rat
    Watabe, Tadashi
    Kainuma, Satoshi
    Miyagawa, Shigeru
    Horitsugi, Genki
    Ikeda, Hayato
    Watabe, Hiroshi
    Fukushima, Satsuki
    Saito, Atsuhiro
    Sawa, Yoshiki
    Hatazawa, Jun
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [3] Evaluation of 18F-labeled BODIPY dye as potential PET agents for myocardial perfusion imaging
    Liu, Shuanglong
    Li, Dan
    Shan, Hong
    Gabbai, Francois P.
    Li, Zibo
    Conti, Peter S.
    NUCLEAR MEDICINE AND BIOLOGY, 2014, 41 (01) : 120 - 126
  • [4] Synthesis and Preliminary Evaluation of 18F-Labeled Pyridaben Analogues for Myocardial Perfusion Imaging with PET
    Mou, Tiantian
    Zhao, Zuoquan
    Fang, Wei
    Peng, Cheng
    Guo, Feng
    Liu, Boli
    Ma, Yunchuan
    Zhang, Xianzhong
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (03) : 472 - 479
  • [5] PET Imaging of brain tumor with 13N-NH3
    Xiangsong, Z.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S94 - S94
  • [6] Identification of cardiac sarcoidosis with 13N-NH3/18F-FDG PET
    Yamagishi, H
    Shirai, N
    Takagi, M
    Yoshiyama, M
    Akioka, K
    Takeuchi, K
    Yoshikawa, J
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (07) : 1030 - 1036
  • [7] Moving into the next era of PET myocardial perfusion imaging: introduction of novel 18F-labeled tracers
    Werner, Rudolf A.
    Chen, Xinyu
    Rowe, Steven P.
    Lapa, Constantin
    Javadi, Mehrbod S.
    Higuchi, Takahiro
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2019, 35 (03): : 569 - 577
  • [8] Moving into the next era of PET myocardial perfusion imaging: introduction of novel 18F-labeled tracers
    Rudolf A. Werner
    Xinyu Chen
    Steven P. Rowe
    Constantin Lapa
    Mehrbod S. Javadi
    Takahiro Higuchi
    The International Journal of Cardiovascular Imaging, 2019, 35 : 569 - 577
  • [9] Synthesis and Biological Evaluation of new 18F-labeled Pyridaben Analogues for PET Myocardial Perfusion Imaging
    Mou, Tiantian
    Zhao, Zuoquan
    Zhang, Xianzhong
    Wang, Qian
    Fang, Wei
    Lu, Jie
    Peng, Cheng
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [10] Right atrial angiosarcoma detected with 13N-NH3 myocardial PET/CT and 18F-FDG PET/CT
    Han-Xiang Liang
    Yue-Long Yang
    Jing-Yun Ren
    Zhi Xie
    Qing Zhang
    En-Tao Liu
    Shu-Xia Wang
    Journal of Nuclear Cardiology, 2023, 30 : 431 - 434