Clinical and Radiologic Outcomes of All-Arthroscopic Latarjet Procedure With Modified Suture Button Fixation: Excellent Bone Healing With a Low Complication Rate

被引:10
|
作者
Shao, Zhenxing [1 ]
Zhao, Yuqing [2 ]
Luo, Hao [1 ]
Jiang, Yanfang [1 ]
Song, Qingfa [1 ]
Cheng, Xu [1 ]
Cui, Guoqing [1 ]
机构
[1] Peking Univ Third Hosp, Dept Sports Med, Beijing, Peoples R China
[2] Peking Univ Third Hosp, Radiol Dept, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
SHOULDER STABILIZATION; FOLLOW-UP; SCREW; BLOCK;
D O I
10.1016/j.arthro.2022.01.020
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: To investigate the clinical outcomes and radiologic evaluation of an all-arthroscopic Latarjet procedure with modified button fixation. Methods: Patients who received all-arthroscopic Latarjet procedure with modified suture button fixation between September 2015 to September 2016 were retrospectively reviewed. Indications for surgery were recurrent anterior shoulder dislocation with any 1 of these 3 conditions: glenoid defect >15%, contact-sport athlete, or failure after Bankart repair. Inclusion criteria included cases who received this surgery. Clinical outcomes were evaluated by University of California Los Angeles, ASES and Rowe score with a minimal follow-up of 3 years. Radiologic assessment on 3D computed tomography scan was performed preoperatively and postoperatively at different time points. Complications were also recorded. Results: A total of 30 patients were eventually included in this study. The mean follow-up time was 38.0 +/- 2.5 months. There were 25 patients who performed contact sports. Of them, 10 patients were without glenoid defect >15% or failed Bankart repair. The remaining 20 patients had glenoid defect >15%, including 2 failed Bankart cases. Ten patients had glenoid defect < 13.5%, and the rest 20 patients had > 13.5%. UCLA, American Shoulder and Elbow Surgeons, and Rowe score significantly improved during follow-up, and the improvement exceeded MCID for all patients. No severe complications were noted. In total, 86.7% of the graft positioning was measured as flush and 13.3% as medial. The bone union rate was 96.7% at 3 months postoperatively and at final follow-up. The remodeling process for the restoration of the normal anatomy of the lower part of glenoid was noted. Conclusions: All-arthroscopic Latarjet with modified suture button fixation can achieve stable fixation of the coracoid, good clinical outcomes (all patients with improvement exceeding MCID), low complications rate. Furthermore, the bone remodeling process contributes to the recovery of the normal anatomy of anteroinferior glenoid. Study Design: Case series; Level of evidence, 4.
引用
收藏
页码:2157 / +
页数:16
相关论文
共 16 条
  • [1] Clinical outcomes and radiologic assessment of a modified suture button arthroscopic Latarjet procedure
    Jian Xu
    Haifeng Liu
    Wei Lu
    Weimin Zhu
    Liangquan Peng
    Kan Ouyang
    Hao Li
    Daping Wang
    BMC Musculoskeletal Disorders, 20
  • [2] Clinical outcomes and radiologic assessment of a modified suture button arthroscopic Latarjet procedure
    Xu, Jian
    Liu, Haifeng
    Lu, Wei
    Zhu, Weimin
    Peng, Liangquan
    Ouyang, Kan
    Li, Hao
    Wang, Daping
    BMC MUSCULOSKELETAL DISORDERS, 2019, 20 (1)
  • [3] All-arthroscopic, guided Eden-Hybbinette procedure using suture-button fixation for revision of failed Latarjet
    Boileau, Pascal
    Duysens, Christophe
    Saliken, David
    Lemmex, Devin B.
    Bonnevialle, Nicolas
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2019, 28 (11) : E377 - E388
  • [4] Tensioning device increases coracoid bone block healing rates in arthroscopic Latarjet procedure with suture-button fixation
    Boileau, Pascal
    Gendre, Patrick
    Saliken, David J.
    Thelu, Charles-Edouard
    Trojani, Christophe
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2022, 31 (07) : 1451 - 1462
  • [5] Modified Arthroscopic Latarjet Procedure: Suture-Button Fixation Achieves Excellent Remodeling at 3-Year Follow-up
    Xu, Jian
    Liu, Haifeng
    Lu, Wei
    Deng, Zhenhan
    Zhu, Weimin
    Peng, Liangquan
    Ouyang, Kan
    Li, Hao
    Wang, Daping
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2020, 48 (01): : 39 - 47
  • [6] Arthroscopic "Double-Inlay" Eden-Hybinette Procedure with Modified Suture Button Fixation for the Revision of Failed Bristow-Latarjet
    Shao, Zhenxing
    Cheng, Xu
    Luo, Hao
    Cui, Guoqing
    ARTHROSCOPY TECHNIQUES, 2021, 10 (12): : E2619 - E2625
  • [7] Suture Button Fixation in Latarjet Has Similar Load to Failure and Clinical Outcomes but Lower Bone Resorption Compared With Screw Fixation: A Systematic Review
    Hali, Nayeem Z.
    Tahir, Muaaz
    Jordan, Robert W.
    Laprus, Hubert
    Woodmass, Jarret
    Alessandro, Peter D. '
    Malik, Shahbaz S.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2024, 40 (05): : 1637 - 1654
  • [8] The arthroscopic Latarjet procedure with a posterior guided system and suture-button fixation enables more precise bone block positioning in the axial plane versus anterior screws fixation
    Gaujac, Nicolas
    Bouche, Pierre-Alban
    Belas, Maxime
    Bonnevialle, Nicolas
    Charousset, Christophe
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2024, 32 (03) : 750 - 762
  • [9] All-Arthroscopic Glenoid Bone Augmentation Using Iliac Crest Autograft Procedure for Recurrent Anterior Shoulder Instability: Button Fixation Is a Feasible and Satisfactory Alternative to Screw Fixation
    Li, Lingzhi
    Lu, Mingfeng
    Zhao, Lilian
    Shen, Zhaoxiong
    He, Lilei
    Xing, Jisi
    Wang, Changbing
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2024, 40 (01): : 16 - 31
  • [10] Clinical outcomes of an all-arthroscopic glenoid reconstruction using iliac crest bone graft with a double cannulated screw fixation technique
    Choke, Abby
    Wonggokusuma, Erick
    Lai, Mun Chun
    Lie, Denny Tjiauw Tjeon
    ASIA-PACIFIC JOURNAL OF SPORT MEDICINE ARTHROSCOPY REHABILITATION AND TECHNOLOGY, 2021, 24 : 41 - 48