Lack of Late Acquired Incomplete Stent Apposition Following Implantation of the Endeavor™ Zotarolimus-Eluting Stent (ZES) in Unselected Patients with Complex Coronary Lesions - An Intravascular Ultrasound (IVUS) Study

被引:0
|
作者
Costa, Ricardo A. [1 ]
Feres, Fausto [1 ]
Andrade, Pedro B. [1 ]
Costa, J. Ribamar, Jr. [1 ]
Abizaid, Alexandre [1 ]
Staico, Rodolfo [1 ]
Tanajura, Luiz F. [1 ]
Maia, Julio P. [1 ]
Sousa, Amanda [1 ]
Sousa, J. Eduardo [1 ]
机构
[1] Inst Dante Pazzanese Cardiol, Sao Paulo, Brazil
来源
AMERICAN JOURNAL OF CARDIOLOGY | 2008年 / 102卷 / 8A期
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:210I / 211I
页数:2
相关论文
共 50 条
  • [1] Efficacy of Endeavor zotarolimus-eluting stent implantation for the treatment of very late stent thrombosis with late-acquired incomplete stent apposition after sirolimus-eluting stent implantation
    Yuki Kakefuda
    Akira Sato
    Hiroaki Watabe
    Hideaki Aihara
    Hidetaka Nishina
    Yuichi Noguchi
    Tomoya Hoshi
    Kazutaka Aonuma
    Heart and Vessels, 2016, 31 : 1196 - 1199
  • [2] Efficacy of Endeavor zotarolimus-eluting stent implantation for the treatment of very late stent thrombosis with late-acquired incomplete stent apposition after sirolimus-eluting stent implantation
    Kakefuda, Yuki
    Sato, Akira
    Watabe, Hiroaki
    Aihara, Hideaki
    Nishina, Hidetaka
    Noguchi, Yuichi
    Hoshi, Tomoya
    Aonuma, Kazutaka
    HEART AND VESSELS, 2016, 31 (07) : 1196 - 1199
  • [3] Impact Of Final Stent Dimensions On Midterm Results Following Zotarolimus-Eluting Stent (Endeavor®) Implantation: A Serial Intravascular Ultrasound Analysis
    Brito, Andre F. L.
    Costa, Jose Ribamar
    Nakashima, Marcelo
    Siqueira, Dimytri
    Costa, Ricardo
    Feres, Fausto
    Abizaid, Andrea
    Abizaid, Alexandre
    Sousa, Amanda
    Sousa, Eduardo
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (6A): : 146D - 146D
  • [4] Late incomplete stent apposition after sirolimus-eluting stent implantation - A serial intravascular ultrasound analysis
    Ako, J
    Morino, Y
    Honda, Y
    Hassan, A
    Sonoda, S
    Yock, PG
    Leon, MB
    Moses, JW
    Bonneau, HN
    Fitzgerald, PJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (06) : 1002 - 1005
  • [5] Change in Peri-Stent Plaque Area Following Sirolimus-Eluting and Zotarolimus-Eluting Stent Implantation: A Serial Intravascular Ultrasound Study
    Yoon, Hyuck-Jun
    Shin, Hong-won
    Hur, Seung-Ho
    Cho, Yun-Kyeong
    Park, Hyoung-Seob
    Kim, Hyungseop
    Nam, Chang-Wook
    Han, Seong-Wook
    Kim, Yoon-Nyun
    Kim, Kwon-Bae
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 103 (9A): : 55B - 55B
  • [6] STENT THROMBOSIS FOLLOWING IMPLANTATION OF ENDEAVOR ZOTAROLIMUS-ELUTING STENTS IN PATIENTS WITH COMPLEX CORONARY LESIONS - INSIGHTS FROM THE LARGE, PROSPECTIVE, RANDOMIZED, MULTICENTER OPTIMIZE TRIAL
    Costa, Ricardo A.
    Abizaid, Alexandre
    Bhatt, Deepak
    Tinoco de Paula, Joao E.
    Siqueira, Dimytri
    Devito, Fernando
    Antonio Marin-Neto, J.
    Botelho, Roberto
    Castello, Helio
    Mangione, Jose
    Meireles, George
    Centemero, Marinella
    Tanajura, Luiz
    Abizaid, Andrea
    Feres, Fausto
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : A1906 - A1906
  • [7] PREDICTORS OF LATE TARGET LESION REVASCULARIZATION AFTER ENDEAVOR AND RESOLUTE ZOTAROLIMUS-ELUTING STENT IMPLANTATION: 3D-INTRAVASCULAR ULTRASOUND AND ANGIOGRAPHIC ANALYSES
    Kitahara, Hideki
    Kume, Teruyoshi
    Waseda, Katsuhisa
    Sakamoto, Kenji
    Yamada, Ryotaro
    Yock, Paul G.
    Yeung, Alan C.
    Fitzgerald, Peter J.
    Honda, Yasuhiro
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E1777 - E1777
  • [8] Incidence and implications of incomplete "crush" stent apposition after sirolimus-eluting treatment of coronary bifurcation lesions - An intravascular ultrasound (IVUS) analysis
    Costa, RA
    Carlier, SG
    Mintz, GS
    Fujii, K
    Costa, JR
    Kimura, M
    Sano, K
    Tanaka, K
    Cristea, E
    Na, YB
    Lansky, AJ
    Dangas, GD
    Mehran, R
    Collins, M
    Kreps, EM
    Stone, GW
    Moses, JW
    Leon, MB
    AMERICAN JOURNAL OF CARDIOLOGY, 2005, 96 (7A): : 81H - 81H
  • [9] Impact of preinterventional plaque composition and eccentricity on late-acquired incomplete stent apposition after sirolimus-eluting stent implantation: an intravascular ultrasound radiofrequency analysis
    Sato, Takao
    Kameyama, Tomoki
    Noto, Takahisa
    Nozawa, Takashi
    Inoue, Hiroshi
    CORONARY ARTERY DISEASE, 2012, 23 (07) : 432 - 437
  • [10] Late incomplete stent apposition following sirolimus-eluting stent: Serial quantitative intravascular ultrasound analysis from the SIRIUS trial
    Ako, J
    Morino, Y
    Honda, Y
    Sonoda, S
    Terashima, M
    Hassan, A
    Leon, MB
    Moses, JW
    Osterle, S
    Brown, CL
    Baim, DS
    Yock, PG
    Fitzgerald, PJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 33A - 33A