Performance of a new pulse contour method for continuous cardiac output monitoring: validation in critically ill patients

被引:37
|
作者
Bendjelid, K. [1 ]
Marx, G. [2 ]
Kiefer, N. [3 ]
Simon, T. P. [2 ]
Geisen, M. [4 ]
Hoeft, A. [3 ]
Siegenthaler, N. [1 ]
Hofer, C. K. [4 ]
机构
[1] Univ Hosp Geneva, Intens Care Serv, CH-1211 Geneva 14, Switzerland
[2] Rhein Westfal TH Aachen, Univ Hosp Aachen, Dept Anaesthesiol, D-52062 Aachen, Germany
[3] Univ Bonn, Dept Anesthesiol & Intens Care Med, Bonn, Germany
[4] Triemli City Hosp Zurich, Inst Anesthesiol & Intens Care Med, Zurich, Switzerland
关键词
continuous cardiac output; pulse wave analysis; transpulmonary thermodilution; PULMONARY-ARTERY CATHETERS; END-DIASTOLIC VOLUME; TRANSPULMONARY THERMODILUTION; RELIABILITY; MANAGEMENT; INDICATOR; AGREEMENT; ACCURACY; PRELOAD; SURGERY;
D O I
10.1093/bja/aet116
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. A new calibrated pulse wave analysis method (VolumeView (TM)/EV1000 (TM), Edwards Lifesciences, Irvine, CA, USA) has been developed to continuously monitor cardiac output (CO). The aim of this study was to compare the performance of the VolumeView method, and of the PiCCO(2)(TM) pulse contour method (Pulsion Medical Systems, Munich, Germany), with reference transpulmonary thermodilution (TPTD) CO measurements. Methods. This was a prospective, multicentre observational study performed in the surgical and interdisciplinary intensive care units of four tertiary hospitals. Seventy-two critically ill patients were monitored with a central venous catheter, and a thermistor-tipped femoral arterial VolumeView (TM) catheter connected to the EV1000 (TM) monitor. After initial calibration by TPTD CO was continuously assessed using the VolumeView-CCO software (CCOvolumeview) during a 72 h period. TPTD was performed in order to obtain reference CO values (COREF). TPTD and arterial wave signals were transmitted to a PiCCO(2)(TM) monitor in order to obtain CCOPicco values. CCOvolumeview and CCOPiCCO were recorded over a 5 min interval before assessment of COTPTD. Bland-Altman analysis, %(errors), and concordance (trend analysis) were calculated. Results. A total of 338 matched sets of data were available for comparison. Bias for CCOvolumeview-COREF was -0.07 litre min(-1) and for CCOPiCCO-COREF +0.03 litre min(-1). Corresponding limits of agreement were 2.00 and 2.48 litre min(-1) (P<0.01), %(errors) 29 and 37%, respectively. Trending capabilities were comparable for both techniques. Conclusions. The performance of the new VolumeView (TM)-CCO method is as reliable as the PiCCO(2)(TM)-CCO pulse wave analysis in critically ill patients. However, an improved precision was observed with the VolumeView (TM) technique. Clinicaltrials.gov identifier. NCT01405040.
引用
收藏
页码:573 / 579
页数:7
相关论文
共 50 条
  • [1] VALIDATION OF A NEW PULSE CONTOUR METHOD FOR CONTINUOUS CARDIAC OUTPUT MONITORING IN CRITICALLY ILL PATIENTS
    Bendjelid, K.
    Marx, G.
    Kiefer, N.
    Simon, T.
    Rex, S.
    Geisen, M.
    Hoeft, A.
    Siegenthaler, N.
    Giraud, R.
    Hofer, C.
    INTENSIVE CARE MEDICINE, 2011, 37 : S184 - S184
  • [2] Nexfin Noninvasive Continuous Hemodynamic Monitoring: Validation against Continuous Pulse Contour and Intermittent Transpulmonary Thermodilution Derived Cardiac Output in Critically Ill Patients
    Ameloot, Koen
    Van De Vijver, Katrijn
    Broch, Ole
    Van Regenmortel, Niels
    De Laet, Inneke
    Schoonheydt, Karen
    Dits, Hilde
    Bein, Berthold
    Malbrain, Andmanu L. N. G.
    SCIENTIFIC WORLD JOURNAL, 2013,
  • [3] Pulse contour cardiac output monitoring is less reliable in critically ill children
    JC Verheul
    A Nusmeier
    J Lemson
    Critical Care, 16 (Suppl 1):
  • [4] A comparison of pulse contour wave analysis and ultrasonic cardiac output monitoring in the critically ill
    Udy, A. A.
    Altukroni, M.
    Jarrett, P.
    Roberts, J. A.
    Lipman, J.
    ANAESTHESIA AND INTENSIVE CARE, 2012, 40 (04) : 631 - 637
  • [5] CARDIAC OUTPUT MEASUREMENTS WITH AN UNCALIBRATED PULSE CONTOUR METHOD IN CRITICALLY ILL PATIENTS: COMPARISON WITH THERMODILUTION AND ECHOCARDIOGRAPHY
    Scolletta, Sabino
    Bodson, Laurent
    Donadello, Katia
    Devigili, Alessandro
    Taccone, Fabio Silvio
    Herpain, Antoine
    Vincent, Jean-Louis
    De Backer, Daniel
    CRITICAL CARE MEDICINE, 2010, 38 (12) : U64 - U64
  • [6] CARDIAC-OUTPUT MONITORING BY CONTINUOUS THERMODILUTION IN CRITICALLY ILL PATIENTS
    LEFRANT, JY
    BRUELLE, P
    SAISSI, G
    DELACOUSSAYE, JE
    ELEDJAM, JJ
    BRITISH JOURNAL OF ANAESTHESIA, 1995, 74 : 9 - 9
  • [7] CARDIAC-OUTPUT ESTIMATION BY PULSE CONTOUR METHODS - VALIDITY OF THEIR USE FOR MONITORING CRITICALLY ILL PATIENT
    JURADO, RA
    MATUCHA, D
    OSBORN, JJ
    SURGERY, 1973, 74 (03) : 358 - 369
  • [8] Pulse-contour analysis: A new method of continuous cardiac output monitoring in pediatric critical care
    Piehl, MD
    Manning, J
    McCurdy, SL
    Rhue, T
    Cairns, B
    PEDIATRIC RESEARCH, 2004, 55 (04) : 60A - 61A
  • [9] CONTINUOUS CARDIAC-OUTPUT MONITORING BY ANALYSIS OF THE PULSE CONTOUR
    DOSSANTOS, P
    COSTE, P
    BERNADET, P
    DURRIEUJAIS, C
    BESSE, P
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1994, 87 (01): : 65 - 74
  • [10] Validation of continuous thermodilution cardiac output in critically ill patients with analysis of systematic errors
    Medin, DL
    Brown, DT
    Wesley, R
    Cunnion, RE
    Ognibene, FP
    JOURNAL OF CRITICAL CARE, 1998, 13 (04) : 184 - 189