Enhancement of cavitation activity and particle removal with pulsed high frequency ultrasound and supersaturation

被引:37
|
作者
Hauptmann, M. [1 ,2 ]
Frederickx, F. [3 ]
Struyf, H. [1 ]
Mertens, P. [1 ]
Heyns, M. [1 ,4 ]
De Gendt, S. [1 ,5 ]
Glorieux, C. [2 ]
Brems, S. [1 ]
机构
[1] IMEC VZW, B-3001 Louvain, Belgium
[2] Katholieke Univ Leuven, Lab Akoestiek Therm Fys, B-3001 Louvain, Belgium
[3] Katholieke Hgsk Leuven, Dept Gezondheidszorg Technol, B-3000 Louvain, Belgium
[4] Katholieke Univ Leuven, Dept Met Kunde Toegepaste Mat Kunde, B-3001 Louvain, Belgium
[5] Katholieke Univ Leuven, Dept Chem, B-3001 Louvain, Belgium
关键词
Acoustic cavitation; Ultrasonic cleaning; Sonochemistry; Nonlinear acoustics; BUBBLES; EMISSION; FIELD; SIZE;
D O I
10.1016/j.ultsonch.2012.04.015
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Megasonic cleaning as applied in leading edge semiconductor device manufacturing strongly relies on the phenomenon of acoustic cavitation. As the occurrence of acoustic cavitation is incorporating a multitude of interdependent effects, the amount of cavitation activity in the cleaning liquid strongly depends on the sonication conditions. It is shown that cavitation activity as measured by means of ultraharmonic cavitation noise can be significantly enhanced when pulsed sonication is applied to a gas supersaturated liquid under traveling wave conditions. It is demonstrated that this enhancement coincides with a dramatic increase in particle removal and is therefore of great interest for megasonic cleaning applications. It is demonstrated that the optimal pulse parameters are determined by the dissolution time of the active bubbles, whereas the amount of cavitation activity depends on the ratio between pulse-off and pulse-on time as well as the applied acoustic power. The optimal pulse-off time is independent of the corresponding pulse-on time but increases significantly with increasing gas concentration. We show that on the other hand, supersaturation is needed to enable acoustic cavitation at aforementioned conditions, but has to be kept below values, for which active bubbles cannot dissolve anymore and are therefore lost during subsequent pulses. For the applicable range of gas contents between 100% and 130% saturation, the optimal pulse-off time reaches values between 150 and 340 ms, respectively. Full particle removal of 78 nm-diameter silica particles at a power density of 0.67 W/cm(2) is obtained for the optimal pulse-off times. The optimal pulse-off time values are derived from the dissolution time of bubbles with a radius of 3.3 mu m and verified experimentally. The bubble radius used in the calculations corresponds to the linear resonance size in a 928 kHz sound field, which demonstrates that the recycling of active bubbles is the main enhancement mechanism. The optimal choice of the pulsing conditions however is constrained by the trade-off between the effective sonication time and the desire to have a sufficient amount of active bubbles at lower powers, which might be necessary if very delicate structures have to be cleaned. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:69 / 76
页数:8
相关论文
共 50 条
  • [1] Influence of surface tension on cavitation noise spectra and particle removal efficiency in high frequency ultrasound fields
    Camerotto, Elisabeth
    Brems, Steven
    Hauptmann, Marc
    Pacco, Antoine
    Struyf, Herbert
    Mertens, Paul W.
    De Gendt, Stefan
    JOURNAL OF APPLIED PHYSICS, 2012, 112 (11)
  • [2] Enhancement and quenching of high-intensity focused ultrasound cavitation activity via short frequency sweep gaps
    Hallez, Loic
    Lee, Judy
    Touyeras, Francis
    Nevers, Aymeric
    Ashokkumar, Muthupandian
    Hihn, Jean-Yves
    ULTRASONICS SONOCHEMISTRY, 2016, 29 : 194 - 197
  • [3] Visualization and optimization of cavitation activity at a solid surface in high frequency ultrasound fields
    Kauer, Markus
    Belova-Magri, Valentina
    Cairos, Carlos
    Schreier, Hans-Juergen
    Mettin, Robert
    ULTRASONICS SONOCHEMISTRY, 2017, 34 : 474 - 483
  • [4] Classification and prediction of inertial cavitation activity induced by pulsed high-intensity focused ultrasound
    Xu, Huan
    He, Longbiao
    Zhong, Bo
    Qiu, Jianmin
    Tu, Juan
    ULTRASONICS SONOCHEMISTRY, 2019, 56 : 77 - 83
  • [5] Inertial Cavitation in Theranostic Nanoemulsions with Simultaneous Pulsed Laser and Low Frequency Ultrasound Excitation
    Arnal, Bastien
    Wei, Chen-Wei
    Xia, Jinjun
    Pelivanov, Ivan M.
    Lombardo, Michael
    Perez, Camilo
    Matula, Thomas J.
    Pozzo, Danilo
    O'Donnell, Matthew
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2014, 2014, 8943
  • [6] Enhancement or Reduction of Sonochemical Activity of Pulsed Ultrasound Compared to Continuous Ultrasound at 20 kHz?
    Sun, Yujing
    Ye, Xingqian
    MOLECULES, 2013, 18 (05) : 4858 - 4867
  • [7] Enhancement of high-frequency acoustic cavitation effects by a low-frequency stimulation
    Iernetti, G
    Ciuti, P
    Dezhkunov, NV
    Reali, M
    Francescutto, A
    ULTRASONICS SONOCHEMISTRY, 1997, 4 (03) : 263 - 268
  • [8] Enhancement of cooling rate by means of high frequency ultrasound
    Monnot, A.
    Boldo, P.
    Gondrexon, N.
    Bontemps, A.
    HEAT TRANSFER ENGINEERING, 2007, 28 (01) : 3 - 8
  • [10] HIGH-FREQUENCY PULSED DOPPLER ULTRASOUND IN NEUROVASCULAR SURGERY
    GILSBACH, J
    HARDERS, A
    ACTA NEUROCHIRURGICA, 1982, 62 (1-2) : 149 - 149