Diagnostic accuracy of dual-energy computed tomography in bone marrow edema with vertebral compression fractures: A meta-analysis

被引:23
|
作者
Yang, Pei [1 ]
Wu, Guangyao [1 ]
Chang, Xiaodan [1 ]
机构
[1] Dalian Univ, Affiliated Zhongshan Hosp, Dept Radiol, 6 Jiefang St, Dalian 116001, Liaoning, Peoples R China
关键词
Dual-energy computed tomography; Bone marrow edema; Vertebral compression fractures; Meta-analysis; CT; LESIONS; PERFORMANCE;
D O I
10.1016/j.ejrad.2017.12.018
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This meta-analysis aimed to evaluate the diagnostic performance of dual-energy computed tomography (DECT) for the bone marrow edema (BME) in patients with vertebral compression fractures. Methods: The PubMed, EMBASE, and the Cochrane Library database were searched up to July 2017 for relevant original studies. Data were extracted to calculate the pooled sensitivity, specificity, diagnostic odds ratio (DOR), positive and negative likelihood ratios (PLR and NLR), and areas under summary receiver operating characteristic (SROC) curves for analysis. Results: A total of seven studies including 510 vertebras were available for the meta-analysis. Overall pooled sensitivity and specificity of DECT for detecting BME were 0.82 (95% CI: 0.76-0.86) and 0.98 (95% CI: 0.97-0.99), respectively. The PLR was 29.74 (95% CI: 15.62-56.61), the NLR was 0.19 (95% CI: 0.11-0.33), and DOR was 201.96 (95% CI: 99.98-407.93). The SROC value was 0.978. In addition, a subgroup analysis was conducted according to the mean time interval between the DECT and MRI. In 5 studies with more than 2 days interval, the pooled sensitivity and specificity of DECT were 0.89 (95% CI: 0.84-0.93) and 0.98 (95% CI: 0.95-0.99), respectively. The AUC value was 0.979. Conclusions: Current evidence of our meta-analysis indicates that DECT has a high diagnostic accuracy in BME of vertebral compression fractures. In addition, DECT may have a less sensitive in BME of hyper-acute period.
引用
收藏
页码:124 / 129
页数:6
相关论文
共 50 条
  • [1] Accuracy of dual-energy computed tomography for bone marrow edema in the sacroiliac joint: A systematic review and meta-analysis
    Li, Xin
    Wang, Jianguo
    Li, Ping
    Zhuang, Shunda
    Jiang, Shun
    Liu, Wenqian
    MEDICINE, 2024, 103 (01) : E36708
  • [2] Dual-Energy Computed Tomography-Based Display of Bone Marrow Edema in Incidental Vertebral Compression Fractures Diagnostic Accuracy and Characterization in Oncological Patients Undergoing Routine Staging Computed Tomography
    Frellesen, Claudia
    Azadegan, Mehrnoush
    Martin, Simon S.
    Otani, Katharina
    D'Angelo, Tommaso
    Booz, Christian
    Eichler, Katrin
    Panahi, Bita
    Kaup, Moritz
    Bauer, Ralf W.
    Vogl, Thomas J.
    Wichmann, Julian L.
    INVESTIGATIVE RADIOLOGY, 2018, 53 (07) : 409 - 416
  • [3] Bone Marrow Edema in Vertebral Compression Fractures: Detection with Dual-Energy CT
    Wang, Chien-Kuo
    Tsai, Jen-Ming
    Chuang, Ming-Tsung
    Wang, Min-Tsung
    Huang, Kuo-Yuan
    Lin, Ruey-Mo
    RADIOLOGY, 2013, 269 (02) : 524 - 532
  • [4] Single-source dual-energy computed tomography for the assessment of bone marrow oedema in vertebral compression fractures: a prospective diagnostic accuracy study
    Torsten Diekhoff
    Nils Engelhard
    Michael Fuchs
    Matthias Pumberger
    Michael Putzier
    Jürgen Mews
    Marcus Makowski
    Bernd Hamm
    Kay-Geert A. Hermann
    European Radiology, 2019, 29 : 31 - 39
  • [5] Single-source dual-energy computed tomography for the assessment of bone marrow oedema in vertebral compression fractures: a prospective diagnostic accuracy study
    Diekhoff, Torsten
    Engelhard, Nils
    Fuchs, Michael
    Pumberger, Matthias
    Putzier, Michael
    Mews, Jurgen
    Makowski, Marcus
    Hamm, Bernd
    Hermann, Kay-Geert A.
    EUROPEAN RADIOLOGY, 2019, 29 (01) : 31 - 39
  • [6] Diagnostic accuracy of dual-energy computed tomography (DECT) to detect non-traumatic bone marrow edema: A systematic review and meta-analysis
    Chen, Zheng
    Chen, Yingmin
    Zhang, Hui
    Jia, Xiuchuan
    Zheng, Xuechao
    Zuo, Tianzi
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 153
  • [7] Diagnostic accuracy of dual-energy CT and virtual non-calcium techniques to evaluate bone marrow edema in vertebral compression fractures
    Giovanni Foti
    Alberto Beltramello
    Matteo Catania
    Stefano Rigotti
    Gerardo Serra
    Giovanni Carbognin
    La radiologia medica, 2019, 124 : 487 - 494
  • [8] Diagnostic accuracy of dual-energy CT and virtual non-calcium techniques to evaluate bone marrow edema in vertebral compression fractures
    Foti, Giovanni
    Beltramello, Alberto
    Catania, Matteo
    Rigotti, Stefano
    Serra, Gerardo
    Carbognin, Giovanni
    RADIOLOGIA MEDICA, 2019, 124 (06): : 487 - 494
  • [9] Diagnostic accuracy of dual-energy computed tomography in patients with gout: A meta-analysis
    Lee, Young Ho
    Song, Gwan Gyu
    SEMINARS IN ARTHRITIS AND RHEUMATISM, 2017, 47 (01) : 95 - 101
  • [10] Dual-Energy CT of Material Decomposition Analysis for Detection with Bone Marrow Edema in Patients with Vertebral Compression Fractures
    Akisato, Kyouhei
    Nishihara, Reisuke
    Okazaki, Hajime
    Masuda, Takanori
    Hironobe, Ayako
    Ishizaki, Hiromi
    Shota, Kondo
    Yamaguchi, Hiroshi
    Funama, Yoshinori
    ACADEMIC RADIOLOGY, 2020, 27 (02) : 227 - 232