Comparison among Reconstruction Algorithms for Quantitative Analysis of 11C-Acetate Cardiac PET Imaging

被引:2
|
作者
Shi, Ximin [1 ,2 ]
Li, Nan [3 ]
Ding, Haiyan [4 ]
Dang, Yonghong [1 ,2 ]
Hu, Guilan [1 ,2 ]
Liu, Shuai [4 ]
Cui, Jie [3 ]
Zhang, Yue [3 ]
Li, Fang [1 ,2 ]
Zhang, Hui [5 ]
Huo, Li [1 ,2 ]
机构
[1] Chinese Acad Med Sci, Peking Union Med Coll Hosp, Dept Nucl Med, 1 Shuaifuyuan, Beijing 100730, Peoples R China
[2] Peking Union Med Coll, 1 Shuaifuyuan, Beijing 100730, Peoples R China
[3] Sinounion Healthcare Inc, Bldg 3-B,Zhongguancun Dong Sheng Int Pioneer Pk, Beijing 100192, Peoples R China
[4] Tsinghua Univ, Sch Med, Dept Biomed Engn, Ctr Biomed Imaging Res, Beijing 100084, Peoples R China
[5] Tsinghua Univ, Sch Med, Dept Biomed Engn, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
POSITRON-EMISSION-TOMOGRAPHY; TIME-OF-FLIGHT; QUANTIFICATION;
D O I
10.1155/2018/9193403
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective. Kinetic modeling of dynamic C-11-acetate PET imaging provides quantitative information for myocardium assessment. The quality and quantitation of PET images are known to be dependent on PET reconstruction methods. This study aims to investigate the impacts of reconstruction algorithms on the quantitative analysis of dynamic C-11-acetate cardiac PET imaging. Methods. Suspected alcoholic cardiomyopathy patients (N = 24) underwent C-11-acetate dynamic PET imaging after low dose CT scan. PET images were reconstructed using four algorithms: filtered backprojection (FBP), ordered subsets expectation maximization (OSEM), OSEM with time-of-flight (TOF), and OSEM with both time-of-flight and point-spread-function (TPSF). Standardized uptake values (SUVs) at different time points were compared among images reconstructed using the four algorithms. Time-activity curves (TACs) in myocardium and blood pools of ventricles were generated from the dynamic image series. Kinetic parameters K-1 and k(2) were derived using a 1-tissue-compartment model for kinetic modeling of cardiac flow from C-11-acetate PET images. Results. Significant image quality improvement was found in the images reconstructed using iterative OSEM-type algorithms (OSME, TOF, and TPSF) compared with FBP. However, no statistical differences in SUVs were observed among the four reconstruction methods at the selected time points. Kinetic parameters K-1 and k(2) also exhibited no statistical difference among the four reconstruction algorithms in terms of mean value and standard deviation. However, for the correlation analysis, OSEM reconstruction presented relatively higher residual in correlation with FBP reconstruction compared with TOF and TPSF reconstruction, and TOF and TPSF reconstruction were highly correlated with each other. Conclusion. All the tested reconstruction algorithms performed similarly for quantitative analysis of C-11-acetate cardiac PET imaging. TOF and TPSF yielded highly consistent kinetic parameter results with superior image quality compared with FBP. OSEM was relatively less reliable. Both TOF and TPSF were recommended for cardiac C-11-acetate kinetic analysis.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] 11C-acetate pet imaging in renal tumor
    Oyama, Nobuyuki
    Tsuchiyama, Katsuki
    Kusukawa, Naoya
    Ito, Hideaki
    Aoki, Yoshitaka
    Miwa, Yoshiji
    Akino, Hironobu
    Yokoyama, Osamu
    Okazawa, Hidehiko
    Fujibayashi, Yasuhisa
    Yonekura, Yoshiharu
    Welch, Michael J.
    JOURNAL OF UROLOGY, 2008, 179 (04): : 376 - 376
  • [2] PET imaging of prostate cancer with 11C-acetate
    Dimitrakopoulou-Strauss, A
    Strauss, LG
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (04) : 556 - 558
  • [3] 11C-acetate PET imaging in prostate cancer
    Michael J. Morris
    Howard I. Scher
    European Journal of Nuclear Medicine and Molecular Imaging, 2007, 34 : 181 - 184
  • [4] 11C-acetate PET imaging of prostate cancer
    Oyama, N
    Akino, H
    Kanamaru, H
    Suzuki, Y
    Muramoto, S
    Yonekura, Y
    Sadato, N
    Yamamoto, K
    Okada, K
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (02) : 181 - 186
  • [5] 11C-acetate PET imaging in prostate cancer
    Morris, Michael J.
    Scher, Howard I.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 (02) : 181 - 184
  • [6] 11C-Acetate PET Imaging in Patients with Multiple Sclerosis
    Takata, Kazushiro
    Kato, Hiroki
    Shimosegawa, Eku
    Okuno, Tatsusada
    Koda, Toru
    Sugimoto, Tomoyuki
    Mochizuki, Hideki
    Hatazawa, Jun
    Nakatsuji, Yuji
    PLOS ONE, 2014, 9 (11):
  • [7] 11C-ACETATE PET IMAGING FOR COMPLICATED RENAL CYSTS
    Oyama, Nobuyuki
    Kurokawa, Tetsuyuki
    Taga, Minekatsu
    Yokogawa, Ryusei
    Ito, Hideaki
    Aoki, Yoshitaka
    Miwa, Yoshiji
    Akino, Hironobu
    Fujibayashi, Yasuhisa
    Kudo, Takashi
    Okazawa, Hidehiko
    Yokoyama, Osamu
    JOURNAL OF UROLOGY, 2009, 181 (04): : 778 - 778
  • [8] 11C-Acetate PET imaging for renal cell carcinoma
    Oyama, Nobuyuki
    Okazawa, Hidehiko
    Kusukawa, Naoya
    Kaneda, Taisei
    Miwa, Yoshiji
    Akino, Hironobu
    Fujibayashi, Yasuhisa
    Yonekura, Yoshiharu
    Welch, Michael J.
    Yokoyama, Osamu
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 (03) : 422 - 427
  • [9] 11C-Acetate PET imaging for renal cell carcinoma
    Nobuyuki Oyama
    Hidehiko Okazawa
    Naoya Kusukawa
    Taisei Kaneda
    Yoshiji Miwa
    Hironobu Akino
    Yasuhisa Fujibayashi
    Yoshiharu Yonekura
    Michael J. Welch
    Osamu Yokoyama
    European Journal of Nuclear Medicine and Molecular Imaging, 2009, 36 : 422 - 427
  • [10] Quantitative measurement of myocardial perfusion with PET using 11C-acetate
    Botond, B.
    Zsolt, L.
    Monika, M.
    Gyula, T.
    Gabor, K.
    Istvan, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S432 - S432