Experimental study on the seismic performance of a prefabricated steel column-column connection

被引:7
|
作者
Yang, Yong [1 ,2 ]
Xu, Longkang [1 ]
Feng, Shiqiang [1 ]
Sun, Dongde [1 ]
Xue, Yicong [1 ]
Yu, Yunlong [1 ,2 ]
机构
[1] Xian Univ Architecture & Technol, Sch Civil Engn, Xian 710055, Shaanxi, Peoples R China
[2] Xian Univ Architecture & Technol, Minist Educ, Key Lab Struct Engn & Earthquake Resistance, Xian 710055, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Prefabricated structure; Steel column-column connection; Pseudostatic test; Theoretical analysis; Seismic performance; BOLTED-FLANGE CONNECTIONS; BEHAVIOR; REDUCTION; SPLICES; MOMENT; DESIGN; IRON;
D O I
10.1016/j.jcsr.2022.107303
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An innovative prefabricated steel column-column connection composed of upper column, lower column, angles, friction device and posttensioned (PT) strands was proposed, in which seismic performance was mainly studied and theoretical analysis was carried out. This paper analyzed the influence of the axial compression ratio, the presence or absence of angle, and the thickness of angle on the failure model, hysteresis curves, skeleton curves, displacement ductility ratio and energy dissipation ability of the specimens. The test results demonstrated that initial stiffness and energy dissipation ability of the specimen increased by 15.1% and 8.6%, respectively, with an increase in the axial compression ratio by 0.11. The load-carrying capacity of the specimen with a 6 mm angle was always greater than that of the specimen without angle under the same loading displacement. The peak load and final cumulative energy dissipation of the specimen with a 6 mm angle increased by 16.3% and 28.7%, respectively, compared to that of the specimen without an angle. Increasing the thickness of the angle could effectively promote the load-carrying capacity and slow the later stiffness degradation and decrease the bucking deformation degree on the lower column flange of the specimen. However, when the thickness of angle is from 0 mm to 6 mm, from 6 mm to 10 mm, from 10 mm to 14 mm, the displacement ductility ratios of specimen is reduced by 21.8%, 11.7% and 39.8% respectively. In addition, an analytical bending capacity model of the connections was developed, which could reasonably predict the load-carrying capacity of the connections.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Experimental study on seismic performance of prefabricated column-column connection with prestressed steel strands
    Zhang, Ailin
    Li, Xinxia
    Yang, Zheng
    Zhang, Yanxia
    Cheng, Mengyao
    [J]. JOURNAL OF BUILDING ENGINEERING, 2022, 47
  • [2] Experimental study on eccentric compression of the prefabricated columns with a new type of column-column connection node
    He, Zongyuan
    Deng, Zhiheng
    Hu, Shaowei
    Liang, Xiaoqin
    [J]. STRUCTURES, 2024, 68
  • [3] Seismic vulnerability of prefabricated reinforced concrete frame structure based on local outsource steel tube bolted column-column connection
    Zhang, Jiaolei
    Li, Jin
    Liang, Qi
    Li, Shufeng
    Yuan, Dawei
    [J]. ADVANCES IN STRUCTURAL ENGINEERING, 2021, 24 (04) : 784 - 796
  • [4] Experimental study on seismic performance of prefabricated beam to column rotation friction energy dissipation connection
    Chen, Yun
    Chen, Chao
    Xu, Zi-Fan
    Yu, Wen-Hua
    [J]. Zhendong Gongcheng Xuebao/Journal of Vibration Engineering, 2022, 35 (01): : 45 - 54
  • [5] Experimental study on seismic performance of composite structure of steel column-integrated prefabricated concrete wall with different connection types
    Chen, Wei
    Tao, Zhong
    Yang, Yu
    Bao, Weizheng
    Li, Zhuojun
    [J]. Jianzhu Jiegou Xuebao/Journal of Building Structures, 2020, 41 (11): : 89 - 98
  • [6] Experimental and Numerical Analyses on the Seismic Performance of a Novel Precast Concrete Column-column Joints with Bolted End-plate Connection
    Zhaoqiang Wang
    Feng Xiong
    Jiang Chen
    Xulong Zhu
    [J]. KSCE Journal of Civil Engineering, 2022, 26 : 4746 - 4759
  • [7] Experimental and Numerical Analyses on the Seismic Performance of a Novel Precast Concrete Column-column Joints with Bolted End-plate Connection
    Wang, Zhaoqiang
    Xiong, Feng
    Chen, Jiang
    Zhu, Xulong
    [J]. KSCE JOURNAL OF CIVIL ENGINEERING, 2022, 26 (11) : 4746 - 4759
  • [8] Experimental and theoretical study on seismic behavior of connection between prefabricated steel-reinforced concrete column and base
    Wu, Chenglong
    Liu, Linguang
    Mou, Ben
    Pan, Wei
    Liu, Jiming
    [J]. ENGINEERING STRUCTURES, 2023, 274
  • [9] Seismic performance of prefabricated steel beam-to-column connections
    Hu, Fangxin
    Shi, Gang
    Bai, Yu
    Shi, Yongjiu
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2014, 102 : 204 - 216
  • [10] Research and prospect on column-column connection of assembled multi-layer steel structure
    Guo, D. M.
    Wang, Y. Q.
    Yi, Y. C.
    [J]. 2019 INTERNATIONAL CONFERENCE ON ADVANCES IN CIVIL ENGINEERING, ENERGY RESOURCES AND ENVIRONMENT ENGINEERING, 2019, 330