Impact of Wind Generators Number and Location on the Resonance Risk of Wind Farm Integration through Flexible HVDC System

被引:0
|
作者
Wang, Xiao [1 ,3 ]
Hu, Xiaobao [1 ,2 ]
Liu, Hui [1 ,3 ]
Wu, Linlin [1 ,3 ]
Sheng, Siqing [2 ]
机构
[1] North China Elect Power Res Inst Co Ltd, State Grid Jibei Elect Power Co Ltd, Res Inst, Beijing, Peoples R China
[2] North China Elect Power Univ, Dept Elect & Elect Engn, Baoding, Peoples R China
[3] Grid Connected Operat Technol Wind Solar Storage, Beijing, Peoples R China
关键词
VOLTAGE STABILITY;
D O I
10.1088/1755-1315/192/1/012012
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Resonances or instability phenomena may occur in wind farms integration through a flexible HVDC transmission system. The relationship between the resonance risk and wind turbines number under different lengths of the line from wind farms to the flexible HVDC converter station is studied in this paper. First, the effect of the line length on the impedance characteristics of interconnected system is analyzed, and the aggregated RLC circuit approach is applied for the quantitative assessment of potential resonance risk. Then, the variation trend of system impedance characteristics caused by different wind turbines number is revealed, and resonance risk affected by the number of wind turbines integrated from the different location is evaluated by calculating system resonance damping around the resonant frequency. Finally, the simulation results on the RT-LAB platform validate the theoretical analysis.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Integration of Wind Farm to VSC-HVDC System
    Jose, Subin
    Geetha, R. S.
    2017 INTERNATIONAL CONFERENCE ON SMART GRIDS, POWER AND ADVANCED CONTROL ENGINEERING (ICSPACE), 2017, : 298 - 302
  • [2] Comparative study of the impact on subsynchronous resonance characteristics from the different location of wind generators in a large wind farm
    Dong, Xiaoliang
    Xie, Xiaorong
    Li, Jiang
    Han, Yingduo
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2015, 35 (20): : 5173 - 5180
  • [3] Integration of Hydrogen Generator into Wind Farm Interconnected HVDC System
    Muyeen, S. M.
    Takahashi, R.
    Murata, T.
    Tamura, J.
    2009 IEEE BUCHAREST POWERTECH, VOLS 1-5, 2009, : 772 - 778
  • [4] Fault Ride-through Method of Flexible HVDC Transmission System for Wind Farm Integration Based on Coordination of Wind Turbines and Distributed Braking Resistors
    Yang R.
    Wang X.
    Chen Q.
    Shi G.
    Shi Z.
    Cai X.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2021, 45 (21): : 103 - 111
  • [5] Electrical resonance mitigation scheme based on damping controller for wind farm integration through VSC-HVDC system
    Hu, Xiaobao
    Wang, Xiao
    Wu, Linlin
    Liu, Hui
    Sheng, Siqing
    JOURNAL OF ENGINEERING-JOE, 2019, (16): : 2957 - 2959
  • [6] The Impact of Integration of the VSC-HVDC Connected Offshore Wind Farm on Torsional Vibrations of Steam Turbine Generators
    Lin, Chi Hsiang
    SUSTAINABILITY, 2023, 15 (01)
  • [7] Broadband Oscillation Mechanism and Analysis for Wind Farm Integration Through MMC-HVDC System
    Li G.
    Wang W.
    Guo J.
    Chen X.
    Liu C.
    He G.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2019, 39 (18): : 5281 - 5297
  • [8] Fault Ride Through Strategy for Wind Farm Integration System via MMC-HVDC
    Xuejun, Xiong
    Meng, Zhou
    Le, Zhao
    Youhua, Jiang
    2022 4TH INTERNATIONAL CONFERENCE ON SMART POWER & INTERNET ENERGY SYSTEMS, SPIES, 2022, : 1130 - 1135
  • [9] Model Predictive Control for Wind Farm Integration through VSC-HVDC
    Li, Lei
    Zhang, Dongying
    PROCEEDINGS OF THE 2018 13TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA 2018), 2018, : 254 - 259
  • [10] HVDC Light for Large Offshore Wind Farm Integration
    Das, D.
    Pan, J.
    Bala, S.
    2012 IEEE POWER ELECTRONICS AND MACHINES IN WIND APPLICATIONS (PEMWA), 2012,