Signal transmission for implantable medical devices using figure-of-eight coils

被引:7
|
作者
Matsuki, H [1 ]
Ofuji, K [1 ]
Chubachi, N [1 ]
Nitta, S [1 ]
机构
[1] TOHOKU UNIV,INST DEV AGING & CANC,SENDAI,MIYAGI 98077,JAPAN
关键词
D O I
10.1109/20.539510
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new skin-transparent signal transmission method is proposed, For applications on high energy-consumption medical devices such as total artificial hearts or implantable FES (Functional Electrical Stimulation) systems, we constructed a transcutaneous signal transmission system using figure-of-eight coils, as it is apparent that these applications need feedback and/or controlling signals for stable and safe opration. By employing figure-of-eight coils, we could reduce noise coming from around the coil and still suppress noise emitted from the transmitting coil. In the animal experiment using a goat, we could successfully observe the fluctuation in the amount of the transmitted energy through skin with figure-of-eight coils of 30mm in diameter. Meanwhile, figure-of-eight coils didn't cause any unfavorable interferances with the electromagnetically driven ventricular assist device connected to the goat's heart at the time.
引用
收藏
页码:5121 / 5123
页数:3
相关论文
共 50 条
  • [1] Deep Transcranial Magnetic Stimulation Using Figure-of-Eight and Halo Coils
    Lu, Mai
    Ueno, Shoogo
    [J]. IEEE TRANSACTIONS ON MAGNETICS, 2015, 51 (11)
  • [2] Deep Transcranial Magnetic Stimulation Using Figure-of-Eight and Halo Coils
    Lu, M.
    Ueno, S.
    [J]. 2015 IEEE MAGNETICS CONFERENCE (INTERMAG), 2015,
  • [3] Deep Transcranial Magnetic Stimulation with Improved Focality Using Figure-of-Eight and Halo Coils
    Lu, Mai
    Ueno, Shoogo
    [J]. 2017 XXXIIND GENERAL ASSEMBLY AND SCIENTIFIC SYMPOSIUM OF THE INTERNATIONAL UNION OF RADIO SCIENCE (URSI GASS), 2017,
  • [5] A Novel Magnetostrictive Curvature Sensor Employing Flexible, Figure-of-Eight Sensing Coils
    Moreton, G.
    Meydan, T.
    Williams, P.
    [J]. IEEE TRANSACTIONS ON MAGNETICS, 2016, 52 (05)
  • [6] Repeatability of spatial measures using figure-of-eight microphones
    Vigeant, Michelle C.
    Giacomoni, Clothilde B.
    Scherma, Amy C.
    [J]. APPLIED ACOUSTICS, 2013, 74 (09) : 1076 - 1084
  • [7] Marked differences in the thermal characteristics of figure-of-eight shaped coils used for repetitive transcranial magnetic stimulation
    Weyh, T
    Wendicke, K
    Mentschel, C
    Zantow, H
    Siebner, HR
    [J]. CLINICAL NEUROPHYSIOLOGY, 2005, 116 (06) : 1477 - 1486
  • [8] Treatment of Distal Phalanx Fracture Using Figure-of-Eight Suturing of the Nail
    Mizanur, S. K.
    Selvin, Bibin
    Patel, Shivam
    Phalak, Mukesh
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (12)
  • [9] Femoral Venous Hemostasis in Children Using the Technique of "Figure-of-Eight" Sutures
    Zhou, Yong
    Guo, Zhifu
    Bai, Yuan
    Zhao, Xianxian
    Qin, Yongwen
    Chen, Shaoping
    Wu, Hong
    Huang, Xinmiao
    Li, Songhua
    Liu, Bo
    [J]. CONGENITAL HEART DISEASE, 2014, 9 (02) : 122 - 125
  • [10] Improved fibre optic respiratory monitoring using a figure-of-eight coil
    Augousti, AT
    Maletras, FX
    Mason, J
    [J]. PHYSIOLOGICAL MEASUREMENT, 2005, 26 (05) : 585 - 590