Gait initiation is impaired in subjects with Parkinson's disease in the OFF state: Evidence from the analysis of the anticipatory postural adjustments through wearable inertial sensors

被引:22
|
作者
Bonora, Gianluca [1 ]
Mancini, Martina [2 ]
Carpinella, Ilaria [1 ]
Chiari, Lorenzo [3 ]
Horak, Fay B. [2 ,4 ]
Ferrarin, Maurizio [1 ]
机构
[1] IRCCS Fdn Don Gnocchi Onlus, Biomed Technol Dept, Via Capecelatro 66, I-20148 Milan, Italy
[2] Oregon Hlth & Sci Univ, Dept Neurol, Sch Med, 3181 Sam Jackson Pk Rd, Portland, OR 97239 USA
[3] Univ Bologna, Dept Elect Elect & Informat Engn Guglielmo Marcon, Viale Risorgimento 2, I-40136 Bologna, Italy
[4] Portland VA Med Ctr, Dept Res, 3710 SW US Vet Hosp Rd, Portland, OR 97239 USA
关键词
Inertial sensors; Force plate; Accelerometry; Spatio-temporal parameters; APA phases; Levodopa; STEP INITIATION; LEVODOPA; BALANCE;
D O I
10.1016/j.gaitpost.2016.10.017
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
People with Parkinson's disease (PD) typically demonstrate impaired anticipatory postural adjustments (APAs) that shift the body center of mass forward (imbalance) and over the stance leg (unloading) prior to gait initiation. APAs are known to be smallest when people with PD are in their OFF-medication state compared to ON-medication or healthy controls. The aim of this pilot study is to validate a previously developed method for the assessment of gait initiation on PD patients in OFF state with body-worn, inertial sensors. Ten subjects with mild-to-moderate idiopathic PD and twelve healthy controls of similar age performed three gait initiation trials. The spatio-temporal parameters of APAs were extracted from three wearable sensors, placed on the shins and on the lower back, and validated with two force plates. Temporal parameters extracted from sensors and force plates, as well as the trunk medio-lateral acceleration and the correspondent displacement of the center of pressure, were significantly correlated. Subjects with PD showed hypometric adjustments in the medio-lateral direction (p-value < 0.003) and increased duration of the unloading phase (p-value = 0.04). The unloading phase was significantly longer than the imbalance (p-value = 0.003) only in subjects with PD. The validity of the method of quantifying APAs from inertial sensors was confirmed in PD subjects by comparison with force plates. Sensitivity in discriminating PD patients from healthy controls was proven by both spatial and temporal parameters. Objective measures of gait initiation deficits with wearable technology provides valuable instrument for the assessment of gait initiation in clinical environments. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:218 / 221
页数:4
相关论文
共 50 条
  • [1] Detection of anticipatory postural adjustments prior to gait initiation using inertial wearable sensors
    Rigoberto Martinez-Mendez
    Masaki Sekine
    Toshiyo Tamura
    Journal of NeuroEngineering and Rehabilitation, 8
  • [2] Detection of anticipatory postural adjustments prior to gait initiation using inertial wearable sensors
    Martinez-Mendez, Rigoberto
    Sekine, Masaki
    Tamura, Toshiyo
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2011, 8
  • [3] Evaluation of gait initiation using inertial sensors in Huntington's Disease: insights into anticipatory postural adjustments and cognitive interference
    Desai, Radhika
    Fritz, Nora E.
    Muratori, Lisa
    Hausdorff, Jeffrey M.
    Busse, Monica
    Quinn, Lori
    GAIT & POSTURE, 2021, 87 : 117 - 122
  • [4] Variability of Anticipatory Postural Adjustments During Gait Initiation in Individuals With Parkinson Disease
    Lin, Cheng-Chieh
    Creath, Robert A.
    Rogers, Mark W.
    JOURNAL OF NEUROLOGIC PHYSICAL THERAPY, 2016, 40 (01): : 40 - 46
  • [5] Are Hypometric Anticipatory Postural Adjustments Contributing to Freezing of Gait in Parkinson's Disease?
    Schlenstedt, Christian
    Mancini, Martina
    Nutt, Jay
    Hiller, Amie P.
    Maetzler, Walter
    Deuschl, Guenther
    Horak, Fay
    FRONTIERS IN AGING NEUROSCIENCE, 2018, 10
  • [6] A SELECTIVE ROLE OF STRIATAL DOPAMINE IN THE TIMING OF ANTICIPATORY POSTURAL ADJUSTMENTS AT GAIT INITIATION IN PATIENTS WITH PARKINSON'S DISEASE
    Palmisano, C.
    Brandt, G.
    Pozzi, N. G.
    Brumberg, J.
    Leporini, A.
    Marotta, G.
    Cavallari, P.
    Frigo, C. A.
    Pezzoli, G.
    Isaias, I. U.
    PARKINSONISM & RELATED DISORDERS, 2018, 46 : E76 - E77
  • [7] In Patients With Parkinson's Disease in an OFF-Medication State, Does Bilateral Electrostimulation of Tibialis Anterior Improve Anticipatory Postural Adjustments During Gait Initiation?
    Delafontaine, Arnaud
    Fourcade, Paul
    Zemouri, Ahmed
    Diakhate, D. G.
    Saiydoun, Gabriel
    Yiou, Eric
    FRONTIERS IN HUMAN NEUROSCIENCE, 2021, 15
  • [8] Effects of ankle dorsiflexion training on anticipatory postural adjustments during gait initiation of patients with Parkinson's disease
    Nagai, A.
    Okinishi, M.
    Kozuki, T.
    Ohata, K.
    Takasaki, S.
    Kojima, H.
    Marumoto, K.
    MOVEMENT DISORDERS, 2023, 38 : S825 - S826
  • [9] Effect of levodopa and DBS on anticipatory postural adjustments in subjects with Parkinson's disease
    Rocchi, L
    Chiari, L
    Horak, FB
    MOVEMENT DISORDERS, 2004, 19 : S187 - S188
  • [10] Events Detection of Anticipatory Postural Adjustments through a Wearable Accelerometer Sensor Is Comparable to That Measured by the Force Platform in Subjects with Parkinson's Disease
    Lencioni, Tiziana
    Meloni, Mario
    Bowman, Thomas
    Marzegan, Alberto
    Caronni, Antonio
    Carpinella, Ilaria
    Castagna, Anna
    Gower, Valerio
    Ferrarin, Maurizio
    Pelosin, Elisa
    SENSORS, 2022, 22 (07)