Type B uncertainty in sound power measurements using comparison method

被引:18
|
作者
da Costa-Félix, RPB [1 ]
机构
[1] INMETRO, Acoust & Vibrat Metrol Div, BR-25250020 Duque De Caxias, RJ, Brazil
关键词
uncertainty budget; sound power measurement; reverberation room;
D O I
10.1016/j.measurement.2005.10.003
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A model for estimating the uncertainty of sound power measurements using a standardized comparison method was developed accordingly to ISO-GUM, and its Type B budget is presented herein. As it does not depend exclusively on the noise source under measurement, but also in other controlled variables, such as equipment setup, data rounding and environmental conditions, its use and evaluation is of most importance to achieve lower uncertainty values. The model was applied in a set of sound power determination of a family of household appliances (blenders), and it was found to be 0.2 dB(A) (k = 1) in average. Comparing the results obtained with the literature and experimental results, it is possible to conclude that both Type A and Type B uncertainties are important in a complete estimation of sound power uncertainty of a particular family of sound sources. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:169 / 175
页数:7
相关论文