Performance of imaging devices versus optic disc and fiber layer photography in a clinical practice guideline for glaucoma diagnosis

被引:0
|
作者
Guerri, Noemi [1 ]
Polo, Vicente [2 ]
Larrosa, Jose M. [2 ]
Ferreras, Antonio [2 ]
Fuertes, Isabel
Pablo, Luis E. [2 ]
机构
[1] Hosp Univ Miguel Servet, Serv Oftalmol, Dept Ophthalmol, Zaragoza 50009, Spain
[2] Univ Zaragoza, Zaragoza, Spain
关键词
Clinical guidelines; Diagnosis; Glaucoma; OPEN-ANGLE GLAUCOMA; AUTOMATED PERIMETRY; NEUROPATHY;
D O I
10.5301/ejo.5000075
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To compare the performance of Moorfields Regression Analysis (MRA) and optical coherence tomography (OCT) with that of photographic evaluation of the optic nerve head and retinal nerve fiber layer (RNFL) in the application of the Finnish Evidence-Based Guideline for Open-Angle Glaucoma (FEBG-OAG). METHODS. Patients referred for glaucoma evaluation (n=312) and subjects selected from the general population (n=41) were included in the study. All subjects underwent ophthalmic evaluation, optic nerve head stereophotography, monochromatic RNFL photography, Heidelberg retina tomography, OCT, and laser polarimetry evaluation. The subjects were classified based on stereophotographic or MRA and OCT results by applying the FEBG-OAG. RESULTS. The specificity of the FEBG-OAG for detecting normal patients (stereophotography and imaging devices) was 78% (strict criteria) and 100% (liberal criteria). Agreement between the stereophotographic evaluation and evaluation based on MRA and OCT was 70.2%. Classification of subjects with similar management advice based on these evaluations had 70.5% agreement. Central corneal thickness was a confounding factor in glaucoma diagnosis. Large optic disc sizes played a major role in misleading the diagnosis compared to small discs. CONCLUSIONS. Central corneal thickness and large optic disc size are confounding factors in glaucoma diagnosis. Moorfields Regression Analysis and OCT allow for objective implementation of the FEBG-OAG compared to conventional stereophotographic evaluation of the neuroretinal structures.
引用
收藏
页码:554 / 562
页数:9
相关论文
共 50 条
  • [1] Glaucoma diagnosis of the optic disc using photography and planimetry
    Jonas, JB
    OPHTHALMOLOGE, 2003, 100 (01): : 13 - 20
  • [2] Optic disc photography and retinal nerve fiber layer photography
    Hoffmann, E. M.
    OPHTHALMOLOGE, 2009, 106 (08): : 683 - 686
  • [3] Evaluation of optic disc and nerve fiber layer in glaucoma - Clinical techniques
    Caprioli, J
    GLAUCOMA IN THE NEW MILLENNIUM, PROCEEDINGS, 2003, : 107 - 114
  • [4] Examination of the optic disc and nerve fiber layer in glaucoma
    Mojon, DS
    Mermoud, A
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1999, 214 (05) : 295 - 299
  • [5] Evaluation of clinical disc asymmetry in glaucoma with nerve fiber layer imaging
    Giaconi, JA
    Nouri-Mahdavi, K
    Hoffman, DC
    Law, SK
    Caprioli, J
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [6] Comparison of nerve fiber layer and optic disc imaging methods for detection of early glaucoma
    Koucheki, B
    Nouri-Mahdavi, K
    Law, SK
    Caprioli, J
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [7] Can Automated Imaging for Optic Disc and Retinal Nerve Fiber Layer Analysis Aid Glaucoma Detection?
    Banister, Katie
    Boachie, Charles
    Bourne, Rupert
    Cook, Jonathan
    Burr, Jennifer M.
    Ramsay, Craig
    Garway-Heath, David
    Gray, Joanne
    McMeekin, Peter
    Hernandez, Rodolfo
    Azuara-Blanco, Augusto
    OPHTHALMOLOGY, 2016, 123 (05) : 930 - 938
  • [8] Advances in imaging of the optic disc and retinal nerve fiber layer
    Trick, Gary L.
    Calotti, Fadi Y.
    Skarf, Barry
    JOURNAL OF NEURO-OPHTHALMOLOGY, 2006, 26 (04) : 284 - 295
  • [9] Imaging the optic nerve head and nerve fiber layer in glaucoma
    Caprioli, J
    Quigley, H
    GLAUCOMA IN THE NEW MILLENNIUM, PROCEEDINGS, 2003, : 129 - 132
  • [10] Influence of Disc Size on Optic Nerve Head versus Retinal Nerve Fiber Layer Assessment for Diagnosing Glaucoma
    Oddone, Francesco
    Centofanti, Marco
    Tanga, Lucia
    Parravano, Mariacristina
    Michelessi, Manuele
    Schiavone, Mauro
    Villani, Carlo Maria
    Fogagnolo, Paolo
    Manni, Gianluca
    OPHTHALMOLOGY, 2011, 118 (07) : 1340 - 1347