Fabrication of ultra-low radioactivity detector holders for Edelweiss-II

被引:13
|
作者
Navick, XF [1 ]
Carty, M
Chapellier, M
Chardin, G
Goldbach, C
Granelli, R
Hervé, S
Karolak, M
Nollez, G
Nizery, F
Riccio, C
Starzynski, P
Villar, V
机构
[1] CEA, Ctr Etudes Nucl Saclay, DSM, DAPNIA, F-91191 Gif Sur Yvette, France
[2] CEA, Ctr Etudes Nucl Saclay, DSM, DRECAM, F-91191 Gif Sur Yvette, France
[3] CNRS, INSU, Inst Astrophys, F-75014 Paris, France
关键词
cryogenic detector; bolometer; holder; low radioactivity; wimp; dark matter;
D O I
10.1016/j.nima.2003.11.290
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In its first stage, the EDELWEISS-II dark matter experiment will use 21 x 320 g ionization-heat bolometers with NTD thermal sensors. To improve the present sensitivity of EDELWEISS to WIMP interactions by a further factor 100, ultra-low radioactivity detector holders exclusively made of copper and Teflon have been designed. The new design is using the relative expansion coefficients of copper, Teflon and germanium to hopefully ensure a dissipation-free detector holding. In order to validate this new holder, we need to compare the vibration behavior of the old holder and the new one. The amplitude of the bolometer vibrations is measured using the variation of capacitance between electrodes sputtered on the Ge crystal and reference electrodes fixed above the detector holders. We present noise measurements and compare them to the equivalent measurements using the detector holders of the Edelweiss-I experiment, which gave very satisfying results. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:189 / 192
页数:4
相关论文
共 50 条
  • [1] Recent validation tests of the Edelweiss II detector holders
    Schwamm, F
    Chapellier, M
    Hervé, S
    Karolak, M
    Navick, XF
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 559 (02): : 669 - 671
  • [2] Search for low-mass WIMPs with EDELWEISS-II heat-and-ionization detectors
    Armengaud, E.
    Augier, C.
    Benoit, A.
    Berge, L.
    Bergmann, T.
    Bluemer, J.
    Broniatowski, A.
    Brudanin, V.
    Censier, B.
    Chapellier, M.
    Charlieux, F.
    Couedo, F.
    Coulter, P.
    Cox, G. A.
    Domange, J.
    Drillien, A. A.
    Dumoulin, L.
    Eitel, K.
    Filosofov, D.
    Fourches, N.
    Gascon, J.
    Gerbier, G.
    Gironnet, J.
    Gros, M.
    Henry, S.
    Heuermann, G.
    Herve, S.
    Juillard, A.
    Kleifges, M.
    Kluck, H.
    Kozlov, V.
    Kraus, H.
    Kudryavtsev, V. A.
    Le Sueur, H.
    Loaiza, P.
    Marnieros, S.
    Menshikov, A.
    Navick, X-F.
    Nones, C.
    Olivieri, E.
    Pari, P.
    Paul, B.
    Robinson, M.
    Rozov, S.
    Sanglard, V.
    Schmidt, B.
    Siebenborn, B.
    Tcherniakhovski, D.
    Torrento-Coello, A. S.
    Vagneron, L.
    PHYSICAL REVIEW D, 2012, 86 (05):
  • [3] Ultra-low radioactivity flexible printed cables
    Arnquist, Isaac J.
    di Vacri, Maria Laura
    Rocco, Nicole
    Saldanha, Richard
    Schlieder, Tyler
    Patel, Raj
    Patil, Jay
    Perez, Mario
    Uka, Harshad
    EPJ Techniques and Instrumentation, 2023, 10 (01)
  • [4] Ultra-low radioactivity Kapton and copper-Kapton laminates
    Arnquist, Isaac J.
    Beck, Chelsie
    di Vacri, Maria Laura
    Harouaka, Khadouja
    Saldanha, Richard
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 959 (959):
  • [5] Innovative, ultra-low cost fabrication methods
    Waganer, LM
    18TH IEEE/NPSS SYMPOSIUM ON FUSION ENGINEERING, 1999, : 77 - 80
  • [6] Ultra-low noise mechanically cooled germanium detector
    Barton, P.
    Amman, M.
    Martin, R.
    Vetter, K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 812 : 17 - 23
  • [7] Detector yields sensitivity with ultra-low power consumption
    Lee, M
    ELECTRONIC DESIGN, 1997, 45 (07) : 162 - 162
  • [8] Fabrication of ultra-low bend loss optical waveguides
    Arriola, A.
    Gross, S.
    Jovanovic, N.
    Charles, N.
    Tuthill, P. G.
    Olaizola, S. M.
    Fuerbach, A.
    Withford, M. J.
    2013 CONFERENCE ON LASERS AND ELECTRO-OPTICS EUROPE AND INTERNATIONAL QUANTUM ELECTRONICS CONFERENCE (CLEO EUROPE/IQEC), 2013,
  • [9] Ultra-low background measurements in a large volume underground detector
    Alimonti, G
    Anghloher, G
    Arpesella, C
    Balata, M
    Bellini, G
    Benziger, J
    Bonetti, S
    Cadonati, L
    Calaprice, FP
    Cecchet, G
    Chen, M
    Darnton, N
    de Bari, A
    Deutsch, M
    Elisei, E
    von Feilitzsch, F
    Galbiati, C
    Gatti, F
    Giammarchi, MG
    Giugni, D
    Goldbrunner, T
    Golubchikov, A
    Goretti, A
    Hagner, T
    Hartmann, FX
    von Hentig, R
    Heusser, G
    Ianni, A
    Jochum, J
    Laubenstein, M
    Lombardi, P
    Magni, S
    Malvezzi, S
    Manno, I
    Manuzio, G
    Masetti, F
    Mazzucato, U
    Meroni, E
    Neff, M
    Nostro, A
    Oberauer, L
    Perotti, A
    Preda, A
    Raghavan, RS
    Ranucci, G
    Resconi, E
    Ruscitti, M
    Scardaoni, R
    Schonert, S
    Smirnov, O
    ASTROPARTICLE PHYSICS, 1998, 8 (03) : 141 - 157
  • [10] An Ultra-Low Power Spike Detector for Implantable Biomedical Systems
    Jalalifar, Majid
    Byun, Gyung-Su
    2013 IEEE 14TH ANNUAL WIRELESS AND MICROWAVE TECHNOLOGY CONFERENCE (WAMICON), 2013,