Simultaneous voltammetric determination of dopamine and uric acid using carbon-encapsulated hollow Fe3O4 nanoparticles anchored to an electrode modified with nanosheets of reduced graphene oxide

被引:14
|
作者
Song, Han [1 ]
Xue, Guipeng [1 ,2 ]
Zhang, Junjie [1 ]
Wang, Gang [3 ]
Ye, Bang-Ce [3 ,4 ]
Sun, Shiguo [1 ]
Tian, Liping [1 ]
Li, Yingchun [1 ,3 ,5 ]
机构
[1] Shihezi Univ, Sch Pharm, Minist Educ, Key Lab Xinjiang Phytomed Resources, Shihezi 832000, Peoples R China
[2] Xinjiang Inst Mat Med, Key Lab Xinjiang Uygur Med, Urumqi 830004, Peoples R China
[3] Shihezi Univ, Sch Chem & Chem Engn, Key Lab Green Proc Chem Engn Xinjiang Bingtuan, Shihezi 832003, Peoples R China
[4] East China Univ Sci & Technol, State Key Lab Bioreactor Engn, Shanghai 200237, Peoples R China
[5] Harbin Inst Technol, Sch Nat Sci & Humanities, Shenzhen 518055, Peoples R China
基金
中国国家自然科学基金;
关键词
Electrochemical sensor; Glassy carbon electrode; Differential pulse voltammetry; Graphene oxide nanosheets; Whole blood analysis; Transmission electron microscopy; Scanning electron microscopy; ASCORBIC-ACID; ELECTROCHEMICAL SENSOR; CARCINOEMBRYONIC ANTIGEN; FUNCTIONALIZED GRAPHENE; NANOTUBES; PERFORMANCE; CONSTRUCTION; SHEETS; FIBERS; LIQUID;
D O I
10.1007/s00604-016-2067-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The authors describe an electrochemical sensor for simultaneous determination of dopamine (DA) and uric acid (UA). The sensor is based on the use of composite materials of carbon-encapsulated hollow magnetite (Fe3O4) nanoparticles and graphene oxide nanosheets, which were homogeneously deposited on a glassy carbon electrode. The morphology of the materials was characterized by transmission electron microscopy and scanning electron microscopy, and the properties of differently decorated electrodes were investigated via cyclic voltammetry and differential pulse voltammetry (DPV). Simultaneous detection of DA and UA was carried out via DPV, and the potentials of electrooxidation peaks are 0.14 V and 0.27 V (vs. SCE) for DA and UA, respectively. The calibration plot is linear from 0.1 to 150 mu M for DA, and from 1.0 to 100 mu M for UA, with detection limits of 0.053 mu M and 0.41 mu M at an S/N ratio of 3. The method was applied to the quantification of DA and UA in brain tissue, urine and whole blood.
引用
收藏
页码:843 / 853
页数:11
相关论文
共 50 条
  • [1] Simultaneous voltammetric determination of dopamine and uric acid using carbon-encapsulated hollow Fe3O4 nanoparticles anchored to an electrode modified with nanosheets of reduced graphene oxide
    Han Song
    Guipeng Xue
    Junjie Zhang
    Gang Wang
    Bang-Ce Ye
    Shiguo Sun
    Liping Tian
    Yingchun Li
    Microchimica Acta, 2017, 184 : 843 - 853
  • [2] Voltammetric determination of nonylphenol using a glassy carbon electrode modified with a nanocomposite consisting of CTAB, Fe3O4 nanoparticles and reduced graphene oxide
    Zou, Jing
    Guo, Manli
    Feng, Yanlong
    Yang, Mei
    Cao, Yujuan
    Zhu, Debin
    Yu, Ying
    MICROCHIMICA ACTA, 2017, 184 (02) : 533 - 540
  • [3] Voltammetric determination of nonylphenol using a glassy carbon electrode modified with a nanocomposite consisting of CTAB, Fe3O4 nanoparticles and reduced graphene oxide
    Jing Zou
    Manli Guo
    Yanlong Feng
    Mei Yang
    Yujuan Cao
    Debin Zhu
    Ying Yu
    Microchimica Acta, 2017, 184 : 533 - 540
  • [4] Simultaneous determination of dopamine, uric acid and ascorbic acid using a glassy carbon electrode modified with reduced graphene oxide
    Wang, Huiwen
    Ren, Fangfang
    Wang, Caiqin
    Yang, Beibei
    Bin, Duan
    Zhang, Ke
    Du, Yukou
    RSC ADVANCES, 2014, 4 (51) : 26895 - 26901
  • [5] Reduced graphene oxide–graphene quantum dots–Fe3O4 nanocomposite modified electrode for determination of dopamine
    Fatemeh Ershadian
    Shahla Elhami
    Chemical Papers, 2023, 77 : 6613 - 6627
  • [6] Electrochemically synthesized partially reduced graphene oxide modified glassy carbon electrode for individual and simultaneous voltammetric determination of ascorbic acid, dopamine and uric acid
    Aneesh, Padamadathil K.
    Nambiar, Sindhu R.
    Rao, Talasila P.
    Ajayaghosh, Ayyappanpillai
    ANALYTICAL METHODS, 2014, 6 (14) : 5322 - 5330
  • [7] Simultaneous and sensitive determination of melatonin and dopamine with Fe3O4 nanoparticle-decorated reduced graphene oxide modified electrode
    Bagheri, H.
    Afkhami, A.
    Hashemi, P.
    Ghanei, M.
    RSC ADVANCES, 2015, 5 (28): : 21659 - 21669
  • [8] Development of a porous reduced graphene oxide modified electrode for simultaneous determination of dopamine and uric acid
    Agadi, Naveenkumar P.
    Tandel, Ranjita
    Seetharamappa, J.
    IONICS, 2023, 29 (11) : 4863 - 4873
  • [9] Development of a porous reduced graphene oxide modified electrode for simultaneous determination of dopamine and uric acid
    Naveenkumar P. Agadi
    Ranjita Tandel
    J. Seetharamappa
    Ionics, 2023, 29 : 4863 - 4873
  • [10] Simultaneous Voltammetric Determination of Mefenamic Acid and Paracetamol using Graphene Nanosheets/Nickel Oxide Nanoparticles Modified Carbon Paste Electrode
    Naeemy, Ali
    Gholam-Shahbazi, Rozhina
    Mohammadi, Ali
    JOURNAL OF ELECTROCHEMICAL SCIENCE AND TECHNOLOGY, 2017, 8 (04) : 282 - 293