共 50 条
Perfusion of kidneys with unformulated "naked" intercellular adhesion molecule-1 antisense oligodeoxynucleotides prevents ischemic/reperfusion injury
被引:26
|作者:
Chen, WH
Bennett, CF
Wang, ME
Dragun, D
Tian, L
Stecker, K
Clark, JH
Kahan, BD
Stepkowski, SM
机构:
[1] Univ Texas, Sch Med, Div Immunol & Organ Transplantat, Dept Surg, Houston, TX 77030 USA
[2] Univ Texas, Sch Med, Dept Pathol, Houston, TX 77030 USA
[3] Franc Velhardt Klin, Berlin, Germany
[4] ISIS Pharmaceut, Carlsbad, CA 92008 USA
关键词:
D O I:
10.1097/00007890-199909270-00022
中图分类号:
R392 [医学免疫学];
Q939.91 [免疫学];
学科分类号:
100102 ;
摘要:
Background We have previously shown that phosphorothioate intercellular adhesion molecule (ICAM)-1 antisense oligodeoxynucleotide (oligo) IP-9125 blocks the expression of rat ICARS-1 mRNA in rat L2 cells. A single ex situ perfusion of grafts with unformulated IP-9125, suspended in Euro-Collins solution, prolonged the survival of kidney allografts in fats. The present experiments examined whether perfusion of kidneys with unformulated IP-9125 prevents ischemic/reperfusion injury Methods. Kidneys were perfused ex situ with 2 mi of Euro-Collins solution without or with IP-9125 and exposed to 30-min cold (4 degrees C storage time) and 30-min warm (anastomosis time) ischemia, Kidneys were then transplanted to syngeneic nephrectomized recipients, Results. Within 24 hr after transplantation, the glomerular filtration rate values were reduced by almost 60% to 0.49+/-0.14 ml/min from 1.20+/-0.27 ml/min in normal kidneys (P<0.001). Kidney perfusion with 10 mg of either IP-12140 (0.41+/-0.07 ml/min) or IP-13944 (0.47+/-0.07 ml/min) control oligo was ineffective. In contrast, perfusion with 10 mg of IP-9125 significantly improved kidney function (0.8+/-0.18 ml/min; P<0.005), whereas the lower doses of 2 mg (0.47+/-0.13 ml/min; NS) or 4 mg (0.54+/-0.01 ml/min; NS) had no significant effect. The glomerular filtration rate results were confirmed by measurements of blood creatinine (CR) levels at 24 hr after grafting: untreated recipients had a twofold higher CR value (0.10+/-0.14 mg/dl) compared with normal controls (0.65+/-0.07 mg/dl; P<0,001). Although perfusion with 10 mg of control IP-12140 (0.80+/-0.14 mg/dl) or IP-13944 (0.65+/-0.07 mg/dl) did not affect CR levels, perfusion with 10 mg of TP-9125 (0.45+/-0.07 mg/dl) lowered CR levels. The Western blots or reverse transcription-polymerase chain reaction experiments performed in kidney transplants within 24 hr after grafting showed that 10 mg of TP-9125 (but not control IP-12140) reduced the expression of ICAM-1 protein and ICAM-1 mRNA, respectively. Conclusions. Perfusion of grafts with unformulated ICAM-1 antisense oligo specifically reduces intragraft ICAM-1 protein expression and prevents ischemic/reperfusion injury.
引用
收藏
页码:880 / 887
页数:8
相关论文