An optimization based algorithm for shunt active filter under unbalanced and nonsinusoidal supply voltages

被引:2
|
作者
Koteswara, Rao U. [1 ]
Mishra, Mahesh K. [1 ]
Vincent, G. [1 ]
机构
[1] Indian Inst Technol, Dept Elect Engn, Madras 600036, Tamil Nadu, India
关键词
active power filter (APF); load compensation; optimization; perfect harmonic cancellation; unbalanced and distorted supply voltages; unity power factor;
D O I
10.1109/ICIEA.2008.4582764
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
When the supply voltages are balanced and sinusoidal, load compensation can give both unity power factor (UPF) and perfect harmonic cancellation (PHC) source currents. But under distorted supply voltages, achieving both UPF and PHC currents are not possible and contradictory to each other. Hence there should be an optimal performance between these two important compensation goals. This paper presents an optimal control algorithm for load compensation under unbalanced and distorted supply voltages. In this algorithm source currents are compensated for reactive, imbalance components and harmonic distortions set by the limits. By satisfying the harmonic distortion limits and power balance, this algorithm gives the source currents which will provide the maximum achievable power factor. The detailed simulation results using MATLAB are presented to support the performance of the proposed optimal control algorithm.
引用
收藏
页码:1475 / 1480
页数:6
相关论文
共 50 条
  • [1] A DSP based optimal algorithm for shunt active filter under nonsinusoidal supply and unbalanced load conditions
    George, Sincy
    Agarwal, Vivek
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2007, 22 (02) : 593 - 601
  • [2] An Optimization-Based Algorithm for Shunt Active Filter Under Distorted Supply Voltages
    Uyyuru, Koteswara Rao
    Mishra, Mahesh K.
    Ghosh, Arindam
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2009, 24 (5-6) : 1223 - 1232
  • [3] A Noniterative Optimized Algorithm for Shunt Active Power Filter Under Distorted and Unbalanced Supply Voltages
    Kanjiya, Parag
    Khadkikar, Vinod
    Zeineldin, Hatem H.
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2013, 60 (12) : 5376 - 5390
  • [4] OPTIMAL SHUNT COMPENSATION FOR UNBALANCED LINEAR LOADS WITH NONSINUSOIDAL SUPPLY VOLTAGES
    BAGHZOUZ, Y
    COX, MD
    [J]. ELECTRIC MACHINES AND POWER SYSTEMS, 1991, 19 (02): : 171 - 183
  • [5] Application of DSOGI-SPLL Algorithm on Shunt Active Power Filter under Unbalanced and Distorted Voltages
    Zhang Xiaoyu
    Xie Yunxiang
    Wang Yingpin
    Nie Xiong
    Li Lanfang
    Zeng Zhiwu
    [J]. 2016 IEEE 8TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE (IPEMC-ECCE ASIA), 2016,
  • [6] A DSP-Based control algorithm for series active filter for optimized compensation under nonsinusoidal and unbalanced voltage conditions
    George, Sincy
    Agarwal, Vivek
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2007, 22 (01) : 302 - 310
  • [7] Predictive Tuned Filter based Reference Current Generation for Shunt Active Power Filter under Distorted and Unbalanced Supply Voltage
    Gali, Vijayakumar
    Gupta, Nitin
    Gupta, R. A.
    [J]. 2018 NATIONAL POWER ENGINEERING CONFERENCE (NPEC), 2018,
  • [8] A novel three-phase active power filter control algorithm with unbalanced and distorted supply voltages
    Mishra, Mahesh K.
    Karthikeyan, K.
    [J]. TENCON 2005 - 2005 IEEE REGION 10 CONFERENCE, VOLS 1-5, 2006, : 2533 - +
  • [9] Optimisation-based strategy for shunt active power filter control under non-ideal supply voltages
    Chang, GW
    Yeh, CM
    [J]. IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2005, 152 (02): : 182 - 190
  • [10] Constant Instantaneous Power Based Controller for a Shunt Active Power Filter under Balanced, Unbalanced, and Distorted Supply Conditions
    Khalid, Saifullah
    Dwivedi, Bharti
    Mishra, V. M.
    [J]. 2015 INTERNATIONAL CONFERENCE ON COMPUTING, COMMUNICATION & AUTOMATION (ICCCA), 2015, : 963 - 967