Direct electron transfer of hemoglobin in a CdS nanorods and Nafion composite film on carbon ionic liquid electrode

被引:71
|
作者
Sun, Wei [1 ]
Wang, Dandan [1 ]
Li, Guicun [2 ]
Zhai, Ziqin [1 ]
Zhao, Ruijun [1 ]
Jiao, Kui [1 ]
机构
[1] Qingdao Univ Sci & Technol, Key Lab Ecochem Engn, Minist Educ, Coll Chem & Mol Engn, Qingdao 266042, Peoples R China
[2] Qingdao Univ Sci & Technol, Key Lab Nanostruct Mat, Qingdao 266042, Peoples R China
基金
中国国家自然科学基金;
关键词
1-butyl-3-methylimidazolium; hexafluorophosphate; hemoglobin; direct electrochemistry; carbon paste electrode; ionic liquid;
D O I
10.1016/j.electacta.2008.06.021
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
In this paper the direct electron transfer of hemoglobin (Hb) was carefully investigated by using a room temperature ionic liquid 1-butyl-3-methylimidazolium hexafluorophosphate(BMIMPF6) modified carbon paste electrode (CILE) as the basal working electrode. Hb was immobilized on the surface of CILE with the nanocomposite film composed of Nafion and CdS nanorods by a step-by-step method. UV-vis and Fr-IR spectra showed that Hb in the composite film remained its native structure. The direct electrochemical behaviors of Hb in the composite film were further studied in a pH 7.0 phosphate buffer solution (PBS). A pair of well-defined and quasi-reversible cyclic voltammetric peaks of Hb was obtained with the formal potential (E-0') at -0.295 V (vs. SCE), which was the characteristic of heme Fe(III)/Fe(II) redox couples. The direct electrochemistry of Hb was achieved on the modified electrode and the apparent heterogeneous electron transfer rate constant (k(s)) was calculated to be 0.291 s(-1). The formal potentials of Hb Fe(III)/Fe(II) couple shifted negatively with the increase of buffer pH and a slope value of -45.1 mV/pH was got, which indicated that one electron transfer accompanied with one proton transportation. The fabricated Hb sensor showed good electrocatalytic manner to the reduction of trichloroacetic acid (TCA). (c) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:8217 / 8221
页数:5
相关论文
共 50 条
  • [1] Direct Electron Transfer of Hemoglobin in a Hydrophilic Ionic Liquid/Gellan Gum Composite Film Modified Carbon Ionic Liquid Electrode
    Qiao, Li-Fang
    Zheng, Jian-Bin
    Gao, Rui-Fang
    Sheng, Qing-Lin
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2010, 57 (4A) : 718 - 725
  • [2] Direct Electrochemistry of Myoglobin in a Nafion-Ionic Liquid Composite Film Modified Carbon Ionic Liquid Electrode
    Sun, Wei
    Li, Xiaoqing
    Jiao, Kui
    ELECTROANALYSIS, 2009, 21 (08) : 959 - 964
  • [3] Electrochemical Biosensor Based on Carbon Ionic Liquid Electrode Modified with Nafion/Hemoglobin/DNA Composite Film
    Sun, Wei
    Wang, Yan
    Li, Xiaoqing
    Wu, Jie
    Zhan, Tianrong
    Jiao, Kui
    ELECTROANALYSIS, 2009, 21 (22) : 2454 - 2460
  • [4] Direct Electrochemistry of Hemoglobin Immobilized in Polyvinylalcohol and Clay Composite Film Modified Carbon Ionic Liquid Electrode
    Hui, Ni
    Gao, Rui-fang
    Li, Xiao-qing
    Sun, Wei
    Jiao, Kui
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2009, 20 (02) : 252 - 258
  • [5] Direct electrochemistry of hemoglobin on an ionic liquid carbon electrode modified with zinc tungstate nanorods
    Ruan, Chengxiang
    Sun, Zhaolan
    Liu, Jun
    Lou, Jin
    Gao, Weimin
    Sun, Wei
    Xiao, Yunsheng
    MICROCHIMICA ACTA, 2012, 177 (3-4) : 457 - 463
  • [6] Direct electrochemistry of hemoglobin on an ionic liquid carbon electrode modified with zinc tungstate nanorods
    Chengxiang Ruan
    Zhaolan Sun
    Jun Liu
    Jin Lou
    Weimin Gao
    Wei Sun
    Yunsheng Xiao
    Microchimica Acta, 2012, 177 : 457 - 463
  • [7] Electrochemistry of hemoglobin entrapped in a Nafion/nano-ZnO film on carbon ionic liquid electrode
    Sun, Wei
    Zhai, ZiQin
    Wang, DanDan
    Liu, ShuFeng
    Jiao, Kui
    BIOELECTROCHEMISTRY, 2009, 74 (02) : 295 - 300
  • [8] Direct electrochemistry of hemoglobin entrapped in dextran film on carbon ionic liquid electrode
    Li, Xiaoqing
    Wang, Yan
    Sun, Xiaoying
    Zhan, Tianrong
    Sun, Wei
    JOURNAL OF CHEMICAL SCIENCES, 2010, 122 (02) : 271 - 278
  • [9] Direct electrochemistry of hemoglobin entrapped in dextran film on carbon ionic liquid electrode
    Xiaoqing Li
    Yan Wang
    Xiaoying Sun
    Tianrong Zhan
    Wei Sun
    Journal of Chemical Sciences, 2010, 122 : 271 - 278
  • [10] Direct Electron Transfer of Hemoglobin on a Carbon Ionic Liquid Electrode with TiO2 Nanopatricle as Enhancer
    Sun, Wei
    Li, Xiao-Qing
    Jiao, Kui
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2008, 55 (05) : 1074 - 1079