The heritability of corneal hysteresis and ocular pulse amplitude - A twin study

被引:52
|
作者
Carbonaro, Francis [1 ]
Andrew, Toby [2 ]
Mackey, David A. [3 ]
Spector, Tim D. [1 ]
Hammond, Chris J. [1 ,4 ]
机构
[1] Kings Coll London, Sch Med, Twin Res & Genet Epidemiol Unit, London WC2R 2LS, England
[2] Univ London Imperial Coll Sci Technol & Med, Dept Epidemiol & Publ Hlth, London, England
[3] Univ Melbourne, Royal Victorian Eye & Ear Hosp, Ctr Eye Res Australia, Melbourne, Vic, Australia
[4] Bromley Hosp NHS Trust, Princess Royal Univ Hosp, Orpington, England
关键词
D O I
10.1016/j.ophtha.2008.02.011
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To examine the roles of genetic and environmental factors in corneal hysteresis and ocular pulse amplitude by performing a classic twin study. Design: Cross-sectional twin study. Participants and/or Controls: Two hundred sixty-four twin pairs: 135 monozygotic (MZ) and 129 dizygotic (DZ). Methods: Corneal hysteresis was measured using the Reichert Ocular Response Analyzer (ORA; Reichert, Buffalo, NY), and ocular pulse amplitude was measured using the Pascal Dynamic Contour Tonometer (DCT; Swiss Microtechnology AG, Port, Switzerland). Main Outcome Measures: Contribution of genetic and environmental effects on corneal hysteresis and OPA among MZ and DZ twins. Results: The mean corneal hysteresis was of 10.24 +/- 1.54 mmHg and the mean ocular pulse amplitude was 2.88 +/- 0.97 mmHg. The MZ correlations were higher than DZ for both corneal hysteresis and ocular pulse amplitude (correlation coefficients, 0.75:0.42 and 0.59:0.32 for MZ:DZ twins, respectively). Modeling suggested heritability of corneal hysteresis of 0.77 (95% confidence interval [CI], 0.70-0.82), with the remaining proportion of variance because of individual environmental effects of 0.23 (95% CI, 0.18-0.30). For ocular pulse amplitude, the heritability was 0.62 (95% CI, 0.51-0.70), with the remaining proportion of variance the result of individual environmental effects of 0.38 (95% CI, 0.30-0.49). Conclusions: This study demonstrated that additive genetic influences explained most of the individual differences in corneal hysteresis and ocular pulse amplitude among these twins.
引用
收藏
页码:1545 / 1549
页数:5
相关论文
共 50 条
  • [1] Correlation between corneal hysteresis, corneal resistance factor, and ocular pulse amplitude in healthy subjects
    Ehongo, A.
    de Maertelaer, V.
    Cullus, P.
    Pourjavan, S.
    [J]. JOURNAL FRANCAIS D OPHTALMOLOGIE, 2008, 31 (10): : 999 - 1005
  • [2] Heritability of Ocular and Corneal Higher Order Aberrations in Koreans: The Healthy Twin Study
    Lim, Dong-Hui
    Han, Gyule
    Chung, Eui-Sang
    Chung, Tae-Young
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [3] Optic disc area and correlation with central corneal thickness, corneal hysteresis and ocular pulse amplitude in glaucoma patients and controls
    Insull, Elizabeth
    Nicholas, Simon
    Ang, Ghee Soon
    Poostchi, Ali
    Chan, Kenneth
    Wells, Anthony
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 38 (09): : 839 - 844
  • [4] The Heritability of Corneal and Ocular Higher-Order Aberrations in Koreans: The Healthy Twin Study
    Lim, Dong Hui
    Kim, Woori
    Han, Gyule
    Bae, Gi Hyun
    Kim, Myung Hun
    Kim, Myoung Joon
    Song, Yun-Mi
    Chung, Eui-Sang
    Chung, Tae-Young
    Sung, Joohon
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (06) : 3919 - 3928
  • [5] Optic disc area and correlation with central corneal thickness, corneal hysteresis and ocular pulse amplitude in glaucoma patients and controls: response
    Ang, Ghee Soon
    Nicholas, Simon
    Wells, Anthony
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 39 (07): : 718 - 718
  • [6] Optic disc area and correlation with central corneal thickness, corneal hysteresis and ocular pulse amplitude in glaucoma patients and controls: comment
    Shoja, Mohammadali M.
    Harris, Alon
    Shoshani, Yochai Z.
    Siesky, Brent
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 39 (07): : 717 - 718
  • [7] Heritability of Pulsatile Ocular Measurements, IOP and Choroidal Blood Flow, and of Corneal Hysteresis
    Descovich, D.
    Roy-Gagnon, M. -H.
    Masse, H.
    Lesk, M. R.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [8] Heritability of Myopia and Ocular Biometrics in Koreans: The Healthy Twin Study
    Chung, Tae-Young
    Lim, Dong Hui
    Kim, Myung Hun
    Lee, Min Gyu
    Chung, Eui Sang
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [9] Heritability of Myopia and Ocular Biometrics in Koreans: The Healthy Twin Study
    Kim, Myung Hun
    Zhao, Di
    Kim, Woori
    Lim, Dong-Hui
    Song, Yun-Mi
    Guallar, Eliseo
    Cho, Juhee
    Sung, Joohon
    Chung, Eui-Sang
    Chung, Tae-Young
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (05) : 3644 - 3649
  • [10] Heritability of central corneal thickness in Chinese: The Guangzhou twin eye study
    Zheng, Yingfeng
    Ge, Jian
    Huang, Guofu
    Zhang, Jian
    Liu, Bin
    Hur, Yoon-Mi
    He, Mingguang
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (10) : 4303 - 4307