Acoustic-noise-optimized diffusion-weighted imaging

被引:13
|
作者
Ott, Martin [1 ]
Blaimer, Martin [1 ]
Grodzki, David M. [2 ]
Breuer, Felix A. [1 ]
Roesch, Julie [3 ]
Doerfler, Arnd [3 ]
Heismann, Bjoern [2 ]
Jakob, Peter M. [4 ]
机构
[1] Res Ctr Magnet Resonance Bavaria, D-97074 Wurzburg, Germany
[2] Siemens Healthcare, Erlangen, Germany
[3] Univ Erlangen Nurnberg, Dept Neuroradiol, Erlangen, Germany
[4] Univ Wurzburg, Dept Expt Phys 5, D-97070 Wurzburg, Germany
关键词
Quiet MRI; Acoustic noise reduction; DWI; Readout-segmented EPI; Patient comfort; ALZHEIMERS-DISEASE; ECHO; MRI; STROKE; REDUCTION; HEARING; EPI;
D O I
10.1007/s10334-015-0492-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This work was aimed at reducing acoustic noise in diffusion-weighted MR imaging (DWI) that might reach acoustic noise levels of over 100 dB(A) in clinical practice. A diffusion-weighted readout-segmented echo-planar imaging (EPI) sequence was optimized for acoustic noise by utilizing small readout segment widths to obtain low gradient slew rates and amplitudes instead of faster k-space coverage. In addition, all other gradients were optimized for low slew rates. Volunteer and patient imaging experiments were conducted to demonstrate the feasibility of the method. Acoustic noise measurements were performed and analyzed for four different DWI measurement protocols at 1.5T and 3T. An acoustic noise reduction of up to 20 dB(A) was achieved, which corresponds to a fourfold reduction in acoustic perception. The image quality was preserved at the level of a standard single-shot (ss)-EPI sequence, with a 27-54 % increase in scan time. The diffusion-weighted imaging technique proposed in this study allowed a substantial reduction in the level of acoustic noise compared to standard single-shot diffusion-weighted EPI. This is expected to afford considerably more patient comfort, but a larger study would be necessary to fully characterize the subjective changes in patient experience.
引用
收藏
页码:511 / 521
页数:11
相关论文
共 50 条
  • [1] Acoustic-noise-optimized diffusion-weighted imaging
    Martin Ott
    Martin Blaimer
    David M. Grodzki
    Felix A. Breuer
    Julie Roesch
    Arnd Dörfler
    Björn Heismann
    Peter M. Jakob
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2015, 28 : 511 - 521
  • [2] Clinical Robustness of Accelerated and Optimized Abdominal Diffusion-Weighted Imaging
    Taron, Jana
    Weiss, Jakob
    Martirosian, Petros
    Seith, Ferdinand
    Stemmer, Alto
    Bamberg, Fabian
    Notohamiprodjo, Mike
    INVESTIGATIVE RADIOLOGY, 2017, 52 (10) : 590 - 595
  • [3] Diffusion-weighted imaging
    Rovaris, M.
    Perego, E.
    Filippi, M.
    NEURODEGENERATION IN MULTIPLE SCLEROSIS, 2007, : 65 - +
  • [4] Diffusion-weighted imaging
    Zimmerman, RA
    CRITICAL REVIEWS IN NEUROSURGERY, 1997, 7 (04) : 221 - 227
  • [5] Diffusion-Weighted Imaging and Diffusion Tensor Imaging
    Raya J.G.
    Current Radiology Reports, 2 (3)
  • [6] Diffusion-weighted imaging of the orbit
    Tejani, A. S.
    Berson, E.
    Phillip, J.
    Feltrin, F. S.
    Bazan, C.
    Raj, K. M.
    Agarwal, A. K.
    Maldjian, J. A.
    Lee, W. -C.
    Yu, F. F.
    CLINICAL RADIOLOGY, 2024, 79 (01) : 10 - 18
  • [7] Hypoglycemia and diffusion-weighted imaging
    Chan, R
    Erbay, S
    Oljeski, S
    Thaler, D
    Bhadelia, R
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2003, 27 (03) : 420 - 423
  • [8] Diffusion-Weighted Genitourinary Imaging
    Maurer, Martin H.
    Haermae, Kirsi Hannele
    Thoeny, Harriet
    UROLOGIC CLINICS OF NORTH AMERICA, 2018, 45 (03) : 407 - +
  • [9] Diffusion-Weighted Imaging of the Chest
    Luna, Antonio
    Sanchez-Gonzalez, Javier
    Caro, Pilar
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2011, 19 (01) : 69 - +
  • [10] Diffusion-weighted imaging in neuroradiology
    Schlamann, M.