Load-carrying capacity of bolted end-plate connections with elastomeric interlayer

被引:0
|
作者
Nasdala, Lutz [1 ]
Blust, Andreas [1 ]
Juengel, Nikolas [2 ]
机构
[1] Offenburg Univ Appl Sci, Badstr 24, D-77652 Offenburg, Germany
[2] Calenberg Ingenieure GmbH, Am Knubel 2-4, D-31020 Salzhemmendorf, Germany
关键词
End-plate connection; Thermal separation; Elastomeric bearing; Biaxial creep tests; Nonlinear viscoelasticity;
D O I
10.1016/j.jcsr.2020.105986
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
For the design of bolted end-plate connections with elastomeric interlayer, according to Eurocode 3, only the flanges can be considered for a transmission of the internal forces. Our investigations show that the webs should be taken into account as well. They contribute to a more even stress distribution in the elastorneric bearing and, thus, enable higher loads with constant dimensions. The FE simulations are based on one- and two-dimensional tensile and compression tests to determine the complex material behavior of the elastomeric interlayer. Good agreement between measurement and simulation is obtained, which in particular can be attributed to the material law: a nonlinear viscoelastic approach combined with the hyperelastic Marlow model. It has been found that the friction coefficient and the Poisson's ratio of the elastomeric interlayer have a significant influence on the load carrying capacity of bolted end-plate connections. (C) 2020 Published by Elsevier Ltd.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Load-carrying capacity of bolted end-plate connections with elastomeric interlayer
    Nasdala, L.
    Blust, A.
    Juengel, N.
    BAUINGENIEUR, 2019, 94 (02): : 63 - 70
  • [2] Influence of End Plate on Load-Carrying Capacity of Bolted Joint Under Tension.
    Trnka, Michael
    Stavebnicky casopis, 1985, 33 (08): : 639 - 652
  • [3] Limit load capacity of end-plate connections with geometrical imperfections
    Biegus, A
    Czemplik, A
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON STEEL STRUCTURES OF THE 2000'S, 2000, : 95 - 100
  • [4] Experimental study on static load-carrying capacity of stainless steel end-plate beam-to-column joints
    Yuan, Huanxin
    Gao, Jundong
    Du, Xinxi
    Yan, Gang
    Jiang, Qinglin
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2021, 42 (12): : 125 - 132
  • [5] Nonlinear response of bolted end-plate steel connections
    Amiri, GG
    Jamalzadeh, M
    ADVANCES IN STRUCTURES, VOLS 1 AND 2, 2003, : 77 - 82
  • [6] Design of end-plate connections with elastomeric intermediate layer
    Nasdala, Lutz
    Hohn, Birger
    Ruehl, Reinhard
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2007, 63 (04) : 494 - 504
  • [7] Experimental investigation of bolted stiffened end-plate and bolted flange-plate connections
    Yilmaz, Orkun
    Bekiroglu, Serkan
    Alemdar, Fatih
    Arslan, Guray
    Sevim, Barn
    Ayvaz, Yusuf
    LATIN AMERICAN JOURNAL OF SOLIDS AND STRUCTURES, 2019, 16 (03):
  • [8] Influence Factors on the Load-Carrying Capacity of Bolted Timber Connections with Slotted-In Steel Plates
    Cao, Jixing
    Liu, Yingyang
    Liu, Qiang
    Liu, Xiaoyan
    Qian, Hui
    JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2023, 35 (05)
  • [9] New generation of bolted bracket connections: Safe load-carrying capacity and structural damage assessment
    Mirzaie Abar, Bahram
    Ghobadi, Mohammad Soheil
    Engineering Structures, 2022, 252
  • [10] New generation of bolted bracket connections: Safe load-carrying capacity and structural damage assessment
    Abar, Bahram Mirzaie
    Ghobadi, Mohammad Soheil
    ENGINEERING STRUCTURES, 2022, 252