Automated thermochemolysis reactor for detection of Bacillus anthracis endospores by gas chromatography-mass spectrometry

被引:7
|
作者
Li, Dan [1 ]
Rands, Anthony D. [2 ]
Losee, Scott C. [2 ]
Holt, Brian C. [3 ]
Williams, John R. [1 ]
Lammert, Stephen A. [2 ]
Robison, Richard A. [4 ]
Tolley, H. Dennis [3 ]
Lee, Milton L. [1 ]
机构
[1] Brigham Young Univ, Dept Chem & Biochem, Provo, UT 84602 USA
[2] Torion Technol, Amer Fork, UT 84003 USA
[3] Brigham Young Univ, Dept Stat, Provo, UT 84602 USA
[4] Brigham Young Univ, Dept Microbiol & Mol Biol, Provo, UT 84602 USA
关键词
Thermochemolysis; Automated reactor; Bacillus anthracis endospores; GC-MS; BIOLOGICAL AGENT DETECTION; PATHOGEN DETECTION SYSTEM; UV FLUORESCENCE; BACTERIAL-CELLS; THREAT AGENTS; SPORES; IDENTIFICATION; AEROSOLS; ACID; BIOTERRORISM;
D O I
10.1016/j.aca.2013.03.011
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An automated sample preparation system was developed and tested for the rapid detection of Bacillus anthracis endospores by gas chromatography-mass spectrometry (GC MS) for eventual use in the field. This reactor is capable of automatically processing suspected bio-threat agents to release and derivatize unique chemical biomarkers by thermochemolysis (TCM). The system automatically controls the movement of sample vials from one position to another, crimping of septum caps onto the vials, precise delivery of reagents, and TCM reaction times and temperatures. The specific operations of introduction of sample vials, solid phase microextraction (SPME) sampling, injection into the GC MS system, and ejection of used vials from the system were performed manually in this study, although they can be integrated into the automated system. Manual SPME sampling is performed by following visual and audible signal prompts for inserting the fiber into and retracting it from the sampling port. A rotating carousel design allows for simultaneous sample collection, reaction, biomarker extraction and analysis of sequential samples. Dipicolinic acid methyl ester (DPAME), 3-methyl-2-butenoic acid methyl ester (a fragment of anthrose) and two methylated sugars were used to compare the performance of the autoreactor with manual TCM. Statistical algorithms were used to construct reliable bacterial endospore signatures, and 24 out of 25 (96%) endospore-forming Bacillus species were correctly identified in a statistically designed test. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:67 / 74
页数:8
相关论文
共 50 条
  • [1] Detection of Mycobacterium tuberculosis in Sputum by Gas Chromatography-Mass Spectrometry of Methyl Mycocerosates Released by Thermochemolysis
    O'Sullivan, Denise M.
    Nicoara, Simona C.
    Mutetwa, Reggie
    Mungofa, Stanley
    Lee, Oona Y-C.
    Minnikin, David E.
    Bardwell, Max W.
    Corbett, Elizabeth L.
    McNerney, Ruth
    Morgan, Geraint H.
    PLOS ONE, 2012, 7 (03):
  • [2] DETECTION OF AN EPOXIDE INTERMEDIATE BY GAS CHROMATOGRAPHY-MASS SPECTROMETRY
    SLACK, JA
    FORDHUTCHINSON, AW
    JOURNAL OF PHARMACY AND PHARMACOLOGY, 1978, 30 : P67 - P67
  • [3] DETECTION OF ORGANOPHOSPHORUS INSECTICIDES BY GAS CHROMATOGRAPHY-MASS SPECTROMETRY
    STAN, HJ
    ABRAHAM, B
    JUNG, J
    KELLERT, M
    STEINLAND, K
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1977, 287 (4-5): : 271 - 285
  • [4] Direct analysis of fatty acid profile from milk by thermochemolysis-gas chromatography-mass spectrometry
    Reis, Mariza Gomes
    dos Reis, Marlon Martins
    Leath, Shane
    Stelwagen, Kerst
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (02) : 316 - 323
  • [5] An automated method for peak detection and matching in large gas chromatography-mass spectrometry data sets
    Dixon, Sarah J.
    Brereton, Richard G.
    Soini, Helena A.
    Novotny, Milos V.
    Penn, Dustin J.
    JOURNAL OF CHEMOMETRICS, 2006, 20 (8-10) : 325 - 340
  • [6] Gas Chromatography-Differential Mobility Spectrometry and Gas Chromatography-Mass Spectrometry for the detection of coliform bacteria
    Saptalena, Lena Ganda
    Kuklya, Andriy
    Telgheder, Ursula
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2015, 388 : 17 - 25
  • [7] Detection by gas chromatography-mass spectrometry of adulterated food supplements
    Popescu, Anca Mihaela
    Radu, Gabriel Lucian
    Onisei, Tatiana
    Raducanu, Adina Elena
    Niculae, Camelia Georgiana
    ROMANIAN BIOTECHNOLOGICAL LETTERS, 2014, 19 (04): : 9485 - 9492
  • [8] Detection of modafinil in human urine by gas chromatography-mass spectrometry
    Tseng, YL
    Uralets, V
    Lin, CT
    Kuo, FH
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 39 (05) : 1042 - 1045
  • [9] GAS CHROMATOGRAPHY-MASS SPECTROMETRY COMBINATIONS
    GREENWAY, AM
    SIMPSON, CF
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1980, 13 (11): : 1131 - 1147
  • [10] RADIO GAS CHROMATOGRAPHY-MASS SPECTROMETRY
    CAMPBELL, IM
    DOERFLER, DL
    ERNST, L
    NULTON, CP
    JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1978, 55 (03) : A249 - A249