A novel convolutional neural network for predicting full dose from low dose PET scans

被引:4
|
作者
Sanaat, Amirhossein [1 ]
Arabi, Hossein [1 ]
Zaidi, Habib [1 ]
机构
[1] Geneva Univ Hosp, Div Nucl Med & Mol Imaging, CH-1211 Geneva, Switzerland
基金
瑞士国家科学基金会;
关键词
D O I
10.1109/nss/mic42101.2019.9059962
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The use of radiolabeled tracers in PET imaging raises concerns owing to potential risks from radiation exposure. Therefore, to reduce this potential risk in diagnostic PET imaging, efforts have been made to decrease the amount of radiotracer administered to the patient. However, decreasing the injected activity reduces the signal-to-noise Ratio (SNR) and deteriorates image quality, thus adversely impacting clinical diagnosis. Previously proposed techniques are complicated and slow, yet they yield satisfactory results at significantly low dose. In this work, we propose a deep learning algorithm to reconstruct full-dose (FD) from low-dose (LD) PET images using a fully convolutional encoder-decoder deep neural network model. The goal is to train a model to learn to reconstruct from images with only 5% of the counts to produce images corresponding to 100% of the dose. Brain PET/CT images of 140 patients acquired on the Siemens Biograph mCT with a standard injected activity of F-18-FDG (205 +/- 10 MBq). Images were acquired for about 20 min. The sinograms of each scan were used to produce a low-dose sinogram by randomly selecting only 1/20(th) of the counts. To avoid over fitting, data augmentation was used. A modified 3D U-Net, was developed to predict standard-dose sinogram (PSS) from their corresponding LD sinogram. Detailed quantitative and qualitative comparison demonstrated the proposed method can generate artefact-free diagnostic quality images that preserve internal structures without noise amplification. The structural similarity index (SSIM) and peak signal to noise ratio (PSNR) were used as quantitative metrics for assessment. For instance, the PSNR and SSIM in selected slices were 37.30 +/- 0.71 and 0.97 +/- 0.02, respectively. The proposed algorithm operates in the projection space and is capable of producing diagnostic quality images with only 5% of the standard injected activity.
引用
收藏
页数:3
相关论文
共 50 条
  • [1] Generating PET images from low-dose data using a cycle PET reconstruction convolutional neural network
    Zhai, Mingwei
    Wang, Hongpeng
    Han, Jianda
    Wu, Tingling
    Ye, Hongwei
    2024 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, ICMA 2024, 2024, : 369 - 374
  • [2] Convolutional neural network-based kidney volume estimation from low-dose unenhanced computed tomography scans
    Mueller, Lukas
    Tibyampansha, Dativa
    Mildenberger, Peter
    Panholzer, Torsten
    Jungmann, Florian
    Halfmann, Moritz C.
    BMC MEDICAL IMAGING, 2023, 23 (01)
  • [3] Convolutional neural network-based kidney volume estimation from low-dose unenhanced computed tomography scans
    Lukas Müller
    Dativa Tibyampansha
    Peter Mildenberger
    Torsten Panholzer
    Florian Jungmann
    Moritz C. Halfmann
    BMC Medical Imaging, 23
  • [4] Low-dose CT via convolutional neural network
    Chen, Hu
    Zhang, Yi
    Zhang, Weihua
    Liao, Peixi
    Li, Ke
    Zhou, Jiliu
    Wang, Ge
    BIOMEDICAL OPTICS EXPRESS, 2017, 8 (02): : 679 - 694
  • [5] A deeper convolutional neural network for denoising low dose CT images
    Kim, Byeongjoon
    Shim, Hyunjung
    Baek, Jongduk
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [6] Deep auto-context convolutional neural networks for standard-dose PET image estimation from low-dose PET/MRI
    Xiang, Lei
    Qiao, Yu
    Nie, Dong
    An, Le
    Lin, Weili
    Wang, Qian
    Shen, Dinggang
    NEUROCOMPUTING, 2017, 267 : 406 - 416
  • [7] Convolutional Neural Network Learning from Combinations of RT Dose Distribution, CT and PET Improves Predicting Locoregional Recurrence for Head and Neck Cancer
    Li, Y.
    Wu, A.
    Qi, M.
    Zhou, L.
    Song, T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : S31 - S31
  • [8] PET dose reduction based on a deep convolutional neural network in simultaneous PET/MR A patient study
    Chen, Shuguang
    Gu, Yusen
    Hu, Pengcheng
    Cao, Tuoyu
    Liu, Hui
    Shi, Hongcheng
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [9] A Lightweight Low-dose PET Image Super-resolution Reconstruction Method based on Convolutional Neural Network
    Liu, Kun
    Yu, Haiyun
    Zhang, Mingyang
    Zhao, Lei
    Wang, Xianghui
    Liu, Shuang
    Li, Haoran
    Yang, Kun
    CURRENT MEDICAL IMAGING, 2023, 19 (12) : 1427 - 1435
  • [10] IMPLEMENTATION OF MODULATED LOW DOSE CT FOR PET/CT SCANS TO REDUCE RADIATION DOSE TO PATIENT
    Ng, W.
    Welch, J.
    Pathmaraj, K.
    Scott, A.
    INTERNAL MEDICINE JOURNAL, 2017, 47 : 33 - 33