Flow-injection method for the determination of serine using immobilized enzyme

被引:11
|
作者
Yaqoob, M [1 ]
Nabi, A [1 ]
机构
[1] Univ Balochristan, Dept Chem, Quetta, Pakistan
关键词
serine; serine dehydratase; immobilized enzyme; flow-injection analysis; spectrophotometer;
D O I
10.1016/S0039-9140(01)00528-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow-injection method for the determination of serine using a mini-column containing immobilized serine dehydratase isolated and purified from rat liver is described. Ammonia produced from the enzymatic reaction is coupled with hypochlorite and phenol in an alkaline medium yields a blue product due to the indophenol anion formation, which is the basis of a spectrophotometric detection at 640 nm. The limit of detection (2 x blank noise) is 0.01 mM with a sample throughput of 25 h(-1). Calibration graph is linear in the range 0.2-1.0 mM, with relative standard deviation 0.6-1.0%. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1181 / 1186
页数:6
相关论文
共 50 条
  • [1] DETERMINATION OF PHOSPHATIDYLCHOLINE IN A FLOW-INJECTION SYSTEM USING IMMOBILIZED ENZYME REACTORS
    MASOOM, M
    ROBERTI, R
    BINAGLIA, L
    [J]. ANALYTICAL BIOCHEMISTRY, 1990, 187 (02) : 240 - 245
  • [2] SELECTIVE FLOW-INJECTION DETERMINATION OF METHANOL USING IMMOBILIZED ENZYME REACTORS
    DEMARIA, CG
    MANZANO, T
    DUARTE, R
    ALONSO, A
    [J]. ANALYTICA CHIMICA ACTA, 1995, 309 (1-3) : 241 - 250
  • [3] FLOW-INJECTION ANALYSIS USING IMMOBILIZED ENZYME REAGENT
    KOJIMA, T
    HARA, Y
    MORISHITA, F
    [J]. BUNSEKI KAGAKU, 1983, 32 (04) : E101 - E108
  • [4] IMMOBILIZED ENZYME FLOW-INJECTION CONDUCTIMETRIC SYSTEM FOR THE DETERMINATION OF ACETYLCHOLINE
    GODINHO, OES
    RODRIGUES, TC
    TUBINO, M
    NETO, GDO
    ALEIXO, LM
    [J]. ANALYTICAL PROCEEDINGS, 1995, 32 (08): : 333 - 335
  • [5] A SIMPLE FLOW-INJECTION METHOD FOR THE DETERMINATION OF BLOOD-GLUCOSE USING A TECHNICON IMMOBILIZED ENZYME COIL
    GIZURARSON, S
    [J]. JOURNAL OF AUTOMATIC CHEMISTRY, 1989, 11 (02): : 87 - 88
  • [6] FLOW-INJECTION METHOD FOR THE POLAROGRAPHIC-DETERMINATION OF L-LACTATE USING AN IMMOBILIZED ENZYME REACTOR
    HIKIMA, S
    HASEBE, K
    KAKIZAKI, T
    [J]. ANALYTICAL SCIENCES, 1992, 8 (02) : 165 - 168
  • [7] SPECTROPHOTOMETRIC DETERMINATION OF MAGNESIUM IN SERUM BY USING A FLOW-INJECTION SYSTEM WITH AN IMMOBILIZED ENZYME REACTOR
    FERNANDEZROMERO, JM
    DECASTRO, MDL
    VALCARCEL, M
    QUILESZAFRA, R
    [J]. ANALYTICA CHIMICA ACTA, 1993, 283 (01) : 447 - 452
  • [8] CHEMICALLY IMMOBILIZED TRI-ENZYME ELECTRODE FOR THE DETERMINATION OF SUCROSE USING FLOW-INJECTION ANALYSIS
    HAMID, JA
    MOODY, GJ
    THOMAS, JDR
    [J]. ANALYST, 1988, 113 (01) : 81 - 85
  • [9] REACTIVATION OF AN IMMOBILIZED ENZYME REACTOR FOR THE DETERMINATION OF ACETYLCHOLINESTERASE INHIBITORS FLOW-INJECTION DETERMINATION OF PARAOXON
    DEMARIA, CG
    MUNOZ, TM
    TOWNSHEND, A
    [J]. ANALYTICA CHIMICA ACTA, 1994, 295 (03) : 287 - 296
  • [10] CHEMILUMINESCENCE DETERMINATION OF PROTEASES BY FLOW-INJECTION USING IMMOBILIZED ISOLUMINOL
    EDWARDS, R
    TOWNSHEND, A
    STODDART, B
    [J]. ANALYST, 1995, 120 (01) : 117 - 120