Field evaluation of a random forest activity classifier for wrist-worn accelerometer data

被引:111
|
作者
Payey, Toby G. [1 ,2 ]
Gilson, Nicholas D. [2 ]
Gomersall, Sjaan R. [2 ]
Clark, Bronwyn [3 ]
Trost, Stewart G. [1 ]
机构
[1] Queensland Univ Technol, Sch Exercise & Nutr Sci, Brisbane, Qld, Australia
[2] Univ Queensland, Sch Human Movement & Nutr Sci, Brisbane, Qld, Australia
[3] Univ Queensland, Sch Publ Hlth, Brisbane, Qld, Australia
关键词
Accelerometer; Random forest classifier; Physical activity; Wrist; ENERGY-EXPENDITURE; PHYSICAL-ACTIVITY; SEDENTARY BEHAVIOR; HIP; PREDICTION;
D O I
10.1016/j.jsams.2016.06.003
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Objectives: Wrist-worn accelerometers are convenient to wear and associated with greater wear-time compliance. Previous work has generally relied on choreographed activity trials to train and test classification models. However, validity in free-living contexts is starting to emerge. Study aims were: (1) train and test a random forest activity classifier for wrist accelerometer data; and (2) determine if models trained on laboratory data perform well under free-living conditions. Design: Twenty-one participants (mean age = 27.6 +/- 6.2) completed seven lab-based activity trials and a 24 h free-living trial (N = 16). Methods: Participants wore a GENEActiv monitor on the non-dominant wrist. Classification models recognising four activity classes (sedentary, stationary+, walking, and running) were trained using time and frequency domain features extracted from 10-s non-overlapping windows. Model performance was evaluated using leave-one-out-cross-validation. Models were implemented using the randomForest package within R. Classifier accuracy during the 24 h free living trial was evaluated by calculating agreement with concurrently worn activPAL monitors. Results: Overall classification accuracy for the random forest algorithm was 92.7%. Recognition accuracy for sedentary, stationary+, walking, and running was 80.1%, 95.7%, 91.7%, and 93.7%, respectively for the laboratory protocol. Agreement with the activPAL data (stepping vs. non-stepping) during the 24 h free-living trial was excellent and, on average, exceeded 90%. The ICC for stepping time was 0.92 (95% Cl = 0.75-0.97). However, sensitivity and positive predictive values were modest. Mean bias was 10.3 min/d (95% LOA = 46.0 to 25.4 min/d). Conclusions: The random forest classifier for wrist accelerometer data yielded accurate group-level predictions under controlled conditions, but was less accurate at identifying stepping verse non-stepping behaviour in free living conditions Future studies should conduct more rigorous field-based evaluations using observation as a criterion measure. (C) 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
引用
下载
收藏
页码:75 / 80
页数:6
相关论文
共 50 条
  • [1] Sleep classification from wrist-worn accelerometer data using random forests
    Sundararajan, Kalaivani
    Georgievska, Sonja
    te Lindert, Bart H. W.
    Gehrman, Philip R.
    Ramautar, Jennifer
    Mazzotti, Diego R.
    Sabia, Severine
    Weedon, Michael N.
    van Someren, Eus J. W.
    Ridder, Lars
    Wang, Jian
    van Hees, Vincent T.
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [2] Sleep classification from wrist-worn accelerometer data using random forests
    Kalaivani Sundararajan
    Sonja Georgievska
    Bart H. W. te Lindert
    Philip R. Gehrman
    Jennifer Ramautar
    Diego R. Mazzotti
    Séverine Sabia
    Michael N. Weedon
    Eus J. W. van Someren
    Lars Ridder
    Jian Wang
    Vincent T. van Hees
    Scientific Reports, 11
  • [3] Validation of the Vivago Wrist-Worn accelerometer in the assessment of physical activity
    Jérémy Vanhelst
    Rémy Hurdiel
    Jacques Mikulovic
    Gilles Bui-Xuân
    Paul Fardy
    Denis Theunynck
    Laurent Béghin
    BMC Public Health, 12
  • [4] Subject Recognition Using Wrist-Worn Triaxial Accelerometer Data
    Mauceri, Stefano
    Smith, Louis
    Sweeney, James
    McDermott, James
    MACHINE LEARNING, OPTIMIZATION, AND BIG DATA, MOD 2017, 2018, 10710 : 574 - 585
  • [5] Validation of the Vivago Wrist-Worn accelerometer in the assessment of physical activity
    Vanhelst, Jeremy
    Hurdiel, Remy
    Mikulovic, Jacques
    Bui-Xuan, Gilles
    Fardy, Paul
    Theunynck, Denis
    Beghin, Laurent
    BMC PUBLIC HEALTH, 2012, 12
  • [6] Hip and Wrist-Worn Accelerometer Data Analysis for Toddler Activities
    Kwon, Soyang
    Zavos, Patricia
    Nickele, Katherine
    Sugianto, Albert
    Albert, Mark V.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2019, 16 (14)
  • [7] Physical Activity Classification Using the GENEA Wrist-Worn Accelerometer
    Zhang, Shaoyan
    Rowlands, Alex V.
    Murray, Peter
    Hurst, Tina L.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2012, 44 (04): : 742 - 748
  • [8] Activity Monitoring with a Wrist-Worn, Accelerometer-Based Device
    Lin, Wen-Yen
    Verma, Vijay Kumar
    Lee, Ming-Yih
    Lai, Chao-Sung
    MICROMACHINES, 2018, 9 (09)
  • [9] Physical Activity Patterns of Adolescents by Wrist-worn Geneactiv Accelerometer
    Sanders, Sarah G.
    Jimenez, Elizabeth Yakes
    Skipper, Betty J.
    Kong, Alberta S.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2015, 47 (05): : 924 - 924
  • [10] Technical variability of the Vivago® wrist-worn accelerometer
    Vanhelst, Jeremy
    Fardy, Paul S.
    Beghin, Laurent
    JOURNAL OF SPORTS SCIENCES, 2014, 32 (19) : 1768 - 1774