Seismic analysis of soil-structure system of nuclear power plant on non-rock site via shaking table test

被引:20
|
作者
Wang Xiaohui [1 ,2 ]
Li Xiaojun [1 ,2 ]
Liu Aiwen [1 ]
He Qiumei [1 ]
Hou Chunlin [3 ]
机构
[1] China Earthquake Adm, Inst Geophys, Beijing 100081, Peoples R China
[2] Beijing Univ Technol, Coll Architecture & Civil Engn, Beijing 100124, Peoples R China
[3] Minist Environm Protect Peoples Republ China, Nucl & Radiat Safety Ctr, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
Non-rock site; Nuclear power plant; Soil-structure interaction; Seismic response; Shake table test; PERFORMANCE-TEST; DESIGN;
D O I
10.1016/j.soildyn.2020.106209
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
The influence analysis of the site condition is a key issue considered in the seismic design of nuclear power engineering on non-rock sites. To study the soil-structure interaction (SSI) effect of the site conditions on the structural seismic response of nuclear power engineering, we used a CAP1400 nuclear power plant as a case study subject and performed a shake table testing of a soil-structure system model. The test results indicate that there are strong nonlinear effects of non-rock site, that is, with increase of seismic input level (peak ground acceleration, PGA), the natural vibration frequency of the soil-structure system decreased significantly, and the damping ratio increased; Under all seismic input levels, the site amplification phenomena occurred in different directions, and the response accelerations of soil and structure in the high-frequency range (>3 Hz) are greatly influenced by the SSI effect; The cracks began to appear in the model soil under lower seismic input level (PGA 0.20 g) and developed, lengthen and widen under the high seismic input level (PGA>0.30 g), and the soil cracks were almost all connected under the SME seismic input level (PGA 0.51 g), but still no micro-cracks were detected on the model structure; Under the SSE seismic input level (PGA >= 0.30 g) the contact surface separation appeared on the contact surfaces of the model soil and the structure foundation, and then under the ultra SME seismic input level (PGA 0.84 g) the structure foundation became unbalanced so that the soil-structure system failed. The influence of the site conditions on the seismic response of the structure was significant. The seismic response analysis and seismic design of the nuclear island structure on no-rock sites should take into account the effects of site conditions and soil-structure interaction.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Shaking Table Test for Seismic Response of Nuclear Power Plant on Non-Rock Site
    Lu, Xinyu
    Jing, Liping
    Ma, Ying
    Yang, Jianhua
    Qi, Wenhao
    SUSTAINABILITY, 2023, 15 (13)
  • [2] Shaking Table Test for Evaluation of Seismic Behavior of Nuclear Power Plants on Non-Rock Site
    Li X.
    Wang X.
    He Q.
    Liu A.
    Wang, Xiaohui (wangxiaohui5000@163.com), 1600, Atomic Energy Press (38): : 31 - 35
  • [3] Shaking table test study of nuclear power plant model considering soil-structure interaction effect
    Zhao, Jinyi
    Chen, Hao
    Zhou, Zhiguang
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2023, 168
  • [4] Evaluation of Soil-Structure Interaction in Structure Models via Shaking Table Test
    Ahn, Seongnoh
    Park, Gun
    Yoon, Hyungchul
    Han, Jae-Hyeok
    Jung, Jongwon
    SUSTAINABILITY, 2021, 13 (09)
  • [5] Shaking Table Test on Seismic Response of Tunnel-Soil Surface Structure System considering Soil-Structure Interaction
    Li, Yantao
    Tian, Ye
    Zong, Jinhui
    SHOCK AND VIBRATION, 2022, 2022
  • [6] Analysis of Seismic Soil-Structure Interaction for a Nuclear Power Plant (HTR-10)
    Wang, Xiaoxin
    Zhou, Qin
    Zhu, Kaixin
    Shi, Li
    Li, Xiaotian
    Wang, Haitao
    SCIENCE AND TECHNOLOGY OF NUCLEAR INSTALLATIONS, 2017, 2017
  • [7] Shaking table tests and numerical analysis of frozen soil-structure interaction system
    Xing S.
    Wu T.
    Li Y.-B.
    Pan X.-Z.
    Yantu Gongcheng Xuebao/Chinese Journal of Geotechnical Engineering, 2021, 43 (11): : 2003 - 2012
  • [8] Numerical simulation of shaking table tests on a soil-structure system
    Chuai, Minzhao
    JOURNAL OF ASIAN ARCHITECTURE AND BUILDING ENGINEERING, 2022, 21 (03) : 1002 - 1018
  • [9] Shaking table model test for seismic response of soft soil site
    Tang, Y.
    Chen, Q.
    Zhao, Z.
    Hong, N.
    Liu, Y.
    GEOSHANGHAI 2024 INTERNATIONAL CONFERENCE, VOL 5, 2024, 1334
  • [10] Application of shape acceleration array technology to shaking table model test of soil-structure system
    Ni Ke-chuang
    Gao Wen-sheng
    ROCK AND SOIL MECHANICS, 2014, 35 : 278 - 283