SNR 1E 0102.2-7219 as an X-ray calibration standard in the 0.5-1.0 keV bandpass and its application to the CCD instruments aboard Chandra, Suzaku, Swift and XMM-Newton

被引:43
|
作者
Plucinsky, Paul P. [1 ]
Beardmore, Andrew P. [2 ]
Foster, Adam [1 ]
Haberl, Frank [3 ]
Miller, Eric D. [4 ]
Pollock, Andrew M. T. [5 ]
Sembay, Steve [2 ]
机构
[1] Harvard Smithsonian Ctr Astrophys, MS-3,60 Garden St, Cambridge, MA 02138 USA
[2] Univ Leicester, Dept Phys & Astron, Leicester LE1 7RH, Leics, England
[3] Max Planck Inst Extraterr Phys, Giessenbachstr, D-85748 Garching, Germany
[4] MIT, Kavli Inst Astrophys & Space Res, Cambridge, MA 02139 USA
[5] Univ Sheffield, Dept Phys & Astron, Hounsfield Rd, Sheffield S3 7RH, S Yorkshire, England
来源
ASTRONOMY & ASTROPHYSICS | 2017年 / 597卷
关键词
instrumentation: detectors; X-rays: individuals: 1E 0102.2-7219; ISM: supernova remnants; supernovae: general; SMALL-MAGELLANIC-CLOUD; RICH SUPERNOVA REMNANT; REFLECTION GRATING SPECTROMETER; PHOTON IMAGING CAMERA; CROSS-CALIBRATION; GALAXY CLUSTERS; HEAVY-ELEMENTS; ACIS INSTRUMENT; IN-ORBIT; EPIC-PN;
D O I
10.1051/0004-6361/201628824
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
Context. The flight calibration of the spectral response of charge-coupled device (CCD) instruments below 1.5 keV is difficult in general because of the lack of strong lines in the on-board calibration sources typically available. This calibration is also a function of time due to the effects of radiation damage on the CCDs and/or the accumulation of a contamination layer on the filters or CCDs. Aims. We desire a simple comparison of the absolute effective areas of the current generation of CCD instruments onboard the following observatories: Chandra ACIS-S3, XMM-Newton (EPIC-MOS and EPIC-pn), Suzaku XIS, and Swift XRT and a straightforward comparison of the time-dependent response of these instruments across their respective mission lifetimes. Methods. We have been using 1E 0102.2-7219, the brightest supernova remnant in the Small Magellanic Cloud, to evaluate and modify the response models of these instruments. 1E 0102.2-7219 has strong lines of O, Ne, and Mg below 1.5 keV and little or no Fe emission to complicate the spectrum. The spectrum of 1E 0102.2-7219 has been well-characterized using the RGS gratings instrument on XMM-Newton and the HETG gratings instrument on Chandra. As part of the activities of the International Astronomical Consortium for High Energy Calibration (IACHEC), we have developed a standard spectral model for 1E 0102.2-7219 and fit this model to the spectra extracted from the CCD instruments. The model is empirical in that it includes Gaussians for the identified lines, an absorption component in the Galaxy, another absorption component in the SMC, and two thermal continuum components with different temperatures. In our fits, the model is highly constrained in that only the normalizations of the four brightest lines/line complexes (the O VII He alpha triplet, O VIII Ly alpha line, the Ne IX He alpha triplet, and the Ne X Ly alpha line) and an overall normalization are allowed to vary, while all other components are fixed. We adopted this approach to provide a straightforward comparison of the measured line fluxes at these four energies. We have examined these measured line fluxes as a function of time for each instrument after applying the most recent calibrations that account for the time-dependent response of each instrument. Results. We performed our effective area comparison with representative, early mission data when the radiation damage and contamination layers were at a minimum, except for the XMM-Newton EPIC-pn instrument which is stable in time. We found that the measured fluxes of the O VII He alpha r line, the O VIII Ly alpha line, the Ne X He alpha r line, and the Ne X Ly alpha line generally agree to within +/- 10% for all instruments, with 38 of our 48 fitted normalizations within +/- 10% of the IACHEC model value. We then fit all available observations of 1E 0102.2-7219 for the CCD instruments close to the on-axis position to characterize the time dependence in the 0.5-1.0 keV band. We present the measured line normalizations as a function of time for each CCD instrument so that the users may estimate the uncertainty in their measured line fluxes for the epoch of their observations.
引用
收藏
页数:31
相关论文
共 3 条
  • [1] Cross-calibration of the X-ray Instruments onboard the Chandra, Suzaku, Swift, and XMM-Newton Observatories using the SNR 1E 0102.2-7219
    Plucinsky, Paul P.
    Beardmore, Andrew P.
    DePasquale, Joseph M.
    Dewey, Daniel
    Foster, Adam
    Haberl, Frank
    Miller, Eric D.
    Pollock, A. M. T.
    Posson-Brown, Jennifer L. L.
    Sembay, Steve
    Smith, Randall K.
    SPACE TELESCOPES AND INSTRUMENTATION 2012: ULTRAVIOLET TO GAMMA RAY, 2012, 8443
  • [2] The SMC SNR 1E0102.2-7219 as a calibration standard for X-ray astronomy in the 0.3-2.5 keV bandpass
    Plucinsky, Paul P.
    Haberl, Frank
    Dewey, Daniel
    Beardmore, Andrew P.
    DePasquale, Joseph M.
    Godet, Olivier
    Grinberg, Victoria
    Miller, Eric D.
    Pollock, A. M. T.
    Sembay, Steve
    Smith, Randall K.
    SPACE TELESCOPES AND INSTRUMENTATION 2008: ULTRAVIOLET TO GAMMA RAY, PTS 1 AND 2, 2008, 7011
  • [3] Cross-calibration of the X-ray instruments onboard the Chandra, INTEGRAL, RXTE, Suzaku, Swift, and XMM-Newton observatories using G21.5-0.9
    Tsujimoto, M.
    Guainazzi, M.
    Plucinsky, P. P.
    Beardmore, A. P.
    Ishida, M.
    Natalucci, L.
    Posson-Brown, J. L. L.
    Read, A. M.
    Saxton, R. D.
    Shaposhnikov, N. V.
    ASTRONOMY & ASTROPHYSICS, 2011, 525