Monte Carlo calculations for gamma-ray mass attenuation coefficients of some soil samples

被引:31
|
作者
Tarim, U. Akar [1 ]
Gurler, O. [1 ]
Ozmutlu, E. N. [1 ]
Yalcin, S. [2 ]
机构
[1] Uludag Univ, Fac Arts & Sci, Dept Phys, TR-16059 Bursa, Turkey
[2] Bitlis Eren Univ, Fac Arts & Sci, Dept Phys, TR-13000 Bitlis, Turkey
关键词
Attenuation coefficient; Monte Carlo; Soil; Gamma-ray; BUILDING-MATERIALS; TRANSMISSION;
D O I
10.1016/j.anucene.2013.03.021
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
We developed a simple Monte Carlo code to determine the mass attenuation coefficients of some soil samples at nine different gamma-ray energies (59.5, 80.9, 122.1, 159.0, 356.5, 511.0, 661.6, 1173.2 and 1332.5 key). Results of the Monte Carlo calculations have been compared with tabulations based upon the results of photon cross section database (XCOM) and with experimental results by other researchers for the same samples. The calculated mass attenuation coefficients were found to be very close to the theoretical values and the experimental results. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:198 / 201
页数:4
相关论文
共 50 条
  • [1] Calculation of gamma-ray mass attenuation coefficients of some Egyptian soil samples using Monte Carlo methods
    Medhat, M. E.
    Demir, Nilgun
    Tarim, Urkiye Akar
    Gurler, Orhan
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2014, 169 (08): : 706 - 714
  • [2] SOME MONTE-CARLO CALCULATIONS OF GAMMA-RAY PENETRATIONS
    PERKINS, JF
    JOURNAL OF APPLIED PHYSICS, 1955, 26 (11) : 1372 - 1377
  • [3] Calculation of gamma ray attenuation coefficients of some granite samples using a Monte Carlo simulation code
    Ozyurt, O.
    Altinsoy, N.
    Karaaslan, S. I.
    Bora, A.
    Buyuk, B.
    Erk, I.
    RADIATION PHYSICS AND CHEMISTRY, 2018, 144 : 271 - 275
  • [4] MONTE CARLO CALCULATIONS OF GAMMA-RAY DOSE
    BROWNELL, GL
    REDDY, A
    PHYSICS IN MEDICINE AND BIOLOGY, 1966, 11 (04): : 616 - &
  • [5] MONTE-CARLO CALCULATIONS OF GAMMA-RAY BACKSCATTERING
    GAYER, A
    BUKSHPAN, S
    NARDI, E
    NUCLEAR INSTRUMENTS & METHODS, 1981, 180 (2-3): : 589 - 595
  • [6] MONTE-CARLO CALCULATIONS OF GAMMA-RAY BACKSCATTERING
    BERGER, MJ
    RASO, DJ
    RADIATION RESEARCH, 1960, 12 (01) : 20 - 37
  • [7] MONTE CARLO DETERMINATION OF INHOMOGENEITY EFFECT ON GAMMA-RAY DETECTION EFFICIENCY IN SOIL SAMPLES
    Celik, Necati
    Cevik, Ugur
    RADIATION PROTECTION DOSIMETRY, 2010, 141 (02) : 178 - 182
  • [8] GAMMA-RAY ATTENUATION COEFFICIENTS
    ROSE, RG
    NUCLEONICS, 1964, 22 (08): : 126 - &
  • [9] GAMMA-RAY ATTENUATION COEFFICIENTS
    BERRY, PF