Polythiophene/graphene oxide nanostructured electrodeposited coating for on-line electrochemically controlled in-tube solid-phase microextraction

被引:32
|
作者
Shamsayei, Maryam [1 ]
Yamini, Yadollah [1 ]
Asiabi, Hamid [1 ]
机构
[1] Tarbiat Modares Univ, Dept Chem, POB 14115-175, Tehran, Iran
关键词
Amitriptyline; Doxepin; Electrochemically controlled in-tube solid phase microextraction; Graphene oxide; Nanostructured; Polythiophene; LIQUID-CHROMATOGRAPHY; FIBER MICROEXTRACTION; ANTIDEPRESSANT DRUGS; GRAPHENE; POLYPYRROLE; NANOPARTICLES; COMPOSITE; EXTRACTION; STABILITY; SILICA;
D O I
10.1016/j.chroma.2016.11.003
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work, a novel polythiophene/graphene oxide (PTh/GO) nanostructured coating was introduced for on-line electrochemically-controlled in-tube solid phase microextraction of amitriptyline (AMI) and doxepin (DOX) as antidepressant drugs. The PTh/GO coating was prepared on the inner surface of a stainless steel tube by a facile in-situ electro-deposition method and it was used as a working electrode for electrochemically control in-tube solid phase microextraction. In the PTh/GO coating, GO acts as an anion dopant and sorbent. The PTh/GO coating, compared to PTh and GO coatings, exhibited enhanced long lifetime, good mechanical stability and a large specific surface area. Regarding the in-tube SPME, some important factors such as the extraction and desorption voltage, extraction and desorption times and flow rates of the sample solution and eluent, which could affect the extraction and separation efficiency of the analytes, were optimized. Total analysis time of this method including the online extraction and desorption time was about 21 min for each sample. AMI and DOX were extracted, separated and determined with limits of detection as small as 0.3 mu g L-1 and 0.5 mu g L-1, respectively. This method showed good linearity in the range of 0.7-200 mu g L-1, 2.3-200 mu g L-1 and 2.9-200 mu g L-1 for AMI, and in the range 0.9-200 mu g L-1, 2.5-200 mu g L-1 and 3.0-200 mu g L-1 for DOX in water, urine and plasma samples, respectively; the coefficients of determination were also equal to or higher than 0.9976. The inter- and intra-assay precisions (RSD%, n=3) were in the range of 2.8-3.4% and 2.9-3.9% at the three concentration levels of 5, 25 and 50 mu g L-1, respectively. Finally, under the optimal conditions, the method was applied for the analysis of the drugs in human urine and plasma pretreated samples and good results were obtained. (C) 2016 Published by Elsevier B.V.
引用
收藏
页码:8 / 17
页数:10
相关论文
共 50 条
  • [1] Electrochemically controlled in-tube solid phase microextraction
    Ahmadi, Seyyed Hamid
    Manbohi, Ahmad
    Heydar, Kourosh Tabar
    [J]. ANALYTICA CHIMICA ACTA, 2015, 853 : 335 - 341
  • [2] Nanostructured polypyrrole for automated and electrochemically controlled in-tube solid-phase microextraction of cationic nitrogen compounds
    Hamid Asiabi
    Yadollah Yamini
    Fatemeh Rezaei
    Shahram Seidi
    [J]. Microchimica Acta, 2015, 182 : 1941 - 1948
  • [3] Nanostructured polypyrrole for automated and electrochemically controlled in-tube solid-phase microextraction of cationic nitrogen compounds
    Asiabi, Hamid
    Yamini, Yadollah
    Rezaei, Fatemeh
    Seidi, Shahram
    [J]. MICROCHIMICA ACTA, 2015, 182 (11-12) : 1941 - 1948
  • [4] Development of a novel graphene/polyaniline electrodeposited coating for on-line in-tube solid phase microextraction of aldehydes in human exhaled breath condensate
    Li, Yu
    Xu, Hui
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2015, 1395 : 23 - 31
  • [5] In-tube solid-phase microextraction and on-line coupling with high-resolution GC
    Wang, H
    Liu, WM
    Guan, YF
    Majors, RE
    [J]. LC GC NORTH AMERICA, 2004, 22 (01) : 16 - +
  • [6] Electroplating of nanostructured polyaniline-polypyrrole composite coating in a stainless-steel tube for on-line in-tube solid phase microextraction
    Asiabi, Hamid
    Yamini, Yadollah
    Seidi, Shahram
    Esrafili, Ali
    Rezaei, Fatemeh
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2015, 1397 : 19 - 26
  • [7] On-line electrochemically controlled in-tube solid phase microextraction of inorganic selenium followed by hydride generation atomic absorption spectrometry
    Asiabi, Hamid
    Yamini, Yadollah
    Seidi, Shahram
    Shamsayei, Maryam
    Safari, Meysam
    Rezaei, Fatemeh
    [J]. ANALYTICA CHIMICA ACTA, 2016, 922 : 37 - 47
  • [8] Electrophoretic deposition of graphene oxide onto carbon fibers for in-tube solid-phase microextraction
    Feng, Juanjuan
    Wang, Xiuqin
    Tian, Yu
    Bu, Yanan
    Luo, Chuannan
    Sun, Min
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2017, 1517 : 209 - 214
  • [9] Adsorbent phases with nanomaterials for in-tube solid-phase microextraction coupled on-line to liquid nanochromatography
    Gonzalez-Fuenzalida, R. A.
    Lopez-Garcia, E.
    Moliner-Martinez, Y.
    Campins-Falco, P.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2016, 1432 : 17 - 25
  • [10] Melamine-formaldehyde aerogel coating for in-tube solid-phase microextraction
    Feng, Juanjuan
    Wang, Xiuqin
    Tian, Yu
    Luo, Chuannan
    Sun, Min
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2018, 1577 : 8 - 14