Are all dialyzers compatible with the convective volumes suggested for postdilution online hemodiafiltration?

被引:44
|
作者
Potier, Jacky [1 ]
Queffeulou, Guillaume [1 ]
Bouet, Julien [1 ]
机构
[1] Cotentin Publ Gen Hosp, Nephrol Hemodialysis Serv, Cherbourg, France
来源
关键词
Albumin loss; Convection; Dialyzers; Hemodiafiltration; Membranes; Middle molecules; ALL-CAUSE MORTALITY; CHRONIC-HEMODIALYSIS PATIENTS; HIGH-FLUX HEMODIALYSIS; DIALYSIS MEMBRANES; REMOVAL; OUTCOMES; TRANSPORT; TOXINS; HDF;
D O I
10.5301/ijao.5000525
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Introduction: The recent analysis of 4 randomized controlled trials has confirmed the lower mortality risk for postdilution online hemodiafiltration (OL-HDF) compared to hemodialysis, and above all for patients with the highest delivered body surface area standardized convective volume (CV/BSA > 23 L/1.73 m(2)/session). Since the impact of the dialyzers used in these trials has never been studied, we retrospectively analyzed clinical tests carried out with 19 commonly used dialyzers. The aim was to provide information on their performances and behavior to aid in an objective choice for therapies associated with OL-HDF. Methods: "Efficiency" was evaluated by measuring the reduction ratio of beta-2 microglobulin (RR beta 2M) and myoglobin (RRmyo) for a CV/BSA between 0 and 30 L, extrapolating them at CV/BSA = 23 L. "Safety" was defined by the safe CV (CVsafe), corresponding to the CV/BSA above which albumin loss is >5 g/session. Results: With CV/BSA = 23 L, all the dialyzers ensure an optimal beta 2M extraction (RR beta 2M: 76%-84.5%). For myoglobin, efficiency disparities are bigger (RRmyo: 40%-85%). Above all, 4/19 dialyzers lose more than 5 g albumin and should not be used under these conditions. Conclusions: It is recommended to prescribe dialyzers that are above all safe. Moreover, if one considers that the removal of middle molecule solutes prevails over the CV necessary for their transmembrane transport, some dialyzers that are more efficient with CV/BSA <23 L than others with CV/BSA >= 23 L might then be prescribed when the conditions do not permit the suggested CV/BSA goal to be achieved.
引用
收藏
页码:460 / 470
页数:11
相关论文
共 50 条
  • [1] Removal capacity of different high-flux dialyzers during postdilution online hemodiafiltration
    Santos Garcia, Alba
    Macias Carmona, Nicolas
    Vega Martinez, Almudena
    Abad Estebanez, Soraya
    Linares Gravalos, Tania
    Aragoncillo Sauco, Ines
    Verdalles Guzman, Ursula
    Panizo Gonzalez, Nayara
    Cruzado Vega, Leonidas
    Lopez Gomez, Juan Manuel
    [J]. HEMODIALYSIS INTERNATIONAL, 2019, 23 (01) : 50 - 57
  • [2] Achieving high convection volumes in postdilution online hemodiafiltration: a prospective multicenter study
    van Zuijdewijn, Camiel L. M. de Roij
    Chapdelaine, Isabelle
    Nube, Menso J.
    Blankestijn, Peter J.
    Bots, Michiel L.
    Konings, Constantijn J. A. M.
    Hovinga, Ton K. Kremer
    Molenaar, Femke M.
    van der Weerd, Neelke C.
    Grooteman, Muriel P. C.
    [J]. CLINICAL KIDNEY JOURNAL, 2017, 10 (06): : 804 - 812
  • [3] ACHIEVING HIGH CONVECTION VOLUMES IN POSTDILUTION ONLINE HEMODIAFILTRATION - PRELIMINARY RESULTS FROM THE FEASIBILITY STUDY
    Van Zuijdewijn, Camiel L. M. De Roij
    Chapdelaine, Isabelle
    Nube, Menso J.
    Blankestijn, Peter J.
    Bots, Michiel L.
    Konings, Stijn J. A. M.
    Van den Dorpel, Marinus A.
    Van der Weerd, Neelke C.
    Ter Wee, Piet M.
    Grooteman, Muriel P. C.
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2014, 29 : 503 - 503
  • [4] High-permeability alternatives to current dialyzers performing both high-flux hemodialysis and postdilution online hemodiafiltration
    Maduell, Francisco
    Rodas, Lida
    Jesus Broseta, Jose
    Gomez, Miguel
    Xipell Font, Marc
    Molina, Alicia
    Montagud-Marrahi, Enrique
    Guillen, Elena
    Arias-Guillen, Marta
    Fontsere, Nestor
    Vera Rivera, Manel
    Rico, Nayra
    [J]. ARTIFICIAL ORGANS, 2019, 43 (10) : 1014 - 1021
  • [5] Dialysis and Patient Factors Which Determine Convective Volume Exchange in Patients Treated by Postdilution Online Hemodiafiltration
    Davenport, Andrew
    [J]. ARTIFICIAL ORGANS, 2016, 40 (12) : 1121 - 1127
  • [6] SERUM SCLEROSTIN LEVELS ARE REDUCED BY TREATMENT WITH ONLINE POSTDILUTION HEMODIAFILTRATION
    van Zuijdewijn, Camiel L. M. de Roij
    Grooteman, Muriel P. C.
    Vervloet, Marc G.
    Nube, Menso J.
    Blankestijn, Peter J.
    van den Dorpel, Marinus A.
    Fouque, Denis
    Pelletier, Solenne
    Bots, Michiel L.
    ter Wee, Piet M.
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2015, 30
  • [7] High-Efficiency Postdilution Online Hemodiafiltration Reduces All-Cause Mortality in Hemodialysis Patients
    Maduell, Francisco
    Moreso, Francesc
    Pons, Mercedes
    Ramos, Rosa
    Mora-Macia, Josep
    Carreras, Jordi
    Soler, Jordi
    Torres, Ferran
    Campistol, Josep M.
    Martinez-Castelao, Alberto
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2013, 24 (03): : 487 - 497
  • [8] Optimized convective transport with automated pressure control in on-line postdilution hemodiafiltration
    Joyeux, V.
    Sjpkens, Y.
    Haddj-Elmrabet, A.
    Bijvoet, A. J.
    Nilsson, L. -G.
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2008, 31 (11): : 928 - 936
  • [9] Optimized convective transport with automated pressure control in on-line postdilution hemodiafiltration
    Joyeux, V.
    Sijpkens, Y.
    Haddj-Elmrabet, A.
    Bijvoet, A.J.
    Nilsson, Lars-Göran
    [J]. International Journal of Artificial Organs, 2008, 31 (11): : 928 - 936
  • [10] Mixed predilution and postdilution online hemodiafiltration compared with the traditional infusion modes
    Pedrini, LA
    De Cristofaro, V
    Pagliari, B
    Samà, F
    [J]. KIDNEY INTERNATIONAL, 2000, 58 (05) : 2155 - 2165