Biomechanical comparison of fixation of type-I fractures of the lateral tibial plateau - Is the antiglide screw effective?

被引:19
|
作者
Parker, PJ
Tepper, KB
Brumback, RJ
Novak, VP
Belkoff, SM
机构
[1] Univ Maryland, Dept Surg, Div Orthopaed, Orthopaed Biomech Lab, Baltimore, MD 21210 USA
[2] Univ Maryland, R Adams Cowley Shock Trauma Ctr, Sect Orthopaed Traumatol, Baltimore, MD 21210 USA
来源
关键词
D O I
10.1302/0301-620X.81B3.9100
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Type-I fractures of the lateral tibial plateau were I simulated by osteotomy in 18 pairs of unembahned cadaver tibiae. One fracture of each pair was fixed with two lag screws whereas the contralateral site was stabilised with three lag screws, or two lag screws pins an antiglide screw. The lateral plateau was displaced downwards using a servohydraulic materials testing machine and the resulting force and articular surface gap were recorded. Yield load was defined as the maximum load needed to create a 2.0 mm articular offset at the fracture line. The yield loads of the three-lag-screw (307 +/- 240 N) and antiglide constructs (342 +/- 249 N) were not significantly different from their two-screw control constructs (231 +/- 227 and 289 +/- 245 N, respectively). We concluded that adding an antiglide screw or a third lag screw did not provide any biomechanical advantage in stabilising these fractures.
引用
收藏
页码:478 / 480
页数:3
相关论文
共 50 条
  • [1] Biomechanical comparison of fixation of type-I fractures of the lateral tibial plateau
    Tan, JW
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (03): : 463 - 463
  • [2] Biomechanical comparison of fixation of type-I fractures of the lateral tibial plateau
    Earnshaw, SA
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (01): : 152 - 153
  • [3] Biomechanical comparison of fixation of type-I fractures of the lateral tibial plateau - Reply
    Parker, PJ
    Tepper, KB
    Brumback, RJ
    Novak, VP
    Belkoff, SM
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (01): : 153 - 153
  • [4] Biomechanical comparison of screw versus screw-plate fixation of type 2 Schatzker fractures of the lateral tibial plateau
    Boisrenoult, P
    Bricteux, S
    Beaufils, P
    Hardy, P
    [J]. REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2000, 86 (07): : 707 - 711
  • [5] A comparison of buttress and raft type fixation of lateral tibial plateau fractures
    Knutson, CM
    Twaddle, BC
    Tencer, AF
    [J]. JOURNAL OF INVESTIGATIVE MEDICINE, 1996, 44 (01) : A141 - A141
  • [6] Biomechanical comparison of plate-screw and screw fixation in medial tibial plateau fractures (Schatzker 4). A model study
    Cift, H.
    Cetik, O.
    Kalaycioglu, B.
    Dirikoglu, M. H.
    Ozkan, K.
    Eksioglu, F.
    [J]. ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2010, 96 (03) : 263 - 267
  • [7] PERCUTANEOUS SCREW FIXATION OF TIBIAL PLATEAU FRACTURES
    KEOGH, P
    KELLY, C
    CASHMAN, WF
    MCGUINNESS, AJ
    OROURKE, SK
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1992, 23 (06): : 387 - 388
  • [8] The effect of screw type on the fixation of depressed fragments in tibial plateau fractures
    [J]. Kummer, F.J., 2001, J. Michael Ryan Publishing Inc. (60):
  • [9] THE ANTIGLIDE PLATE FOR DISTAL FIBULAR FIXATION - A BIOMECHANICAL COMPARISON WITH FIXATION WITH A LATERAL PLATE
    SCHAFFER, JJ
    MANOLI, A
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1987, 69A (04): : 596 - 604
  • [10] Suture versus screw fixation of displaced tibial eminence fractures: A biomechanical comparison
    Bong, MR
    Romero, A
    Kubiak, E
    Iesaka, K
    Heywood, CS
    Kummer, F
    Rosen, J
    Jazrawi, L
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2005, 21 (10): : 1172 - 1176