Determination of Am and Cm in spent nuclear fuels by isotope dilution inductively coupled plasma mass spectrometry and isotope dilution thermal ionization mass spectrometry after separation by high-performance liquid chromatography

被引:64
|
作者
Chartier, F [1 ]
Aubert, M [1 ]
Pilier, M [1 ]
机构
[1] CEA Saclay, DCC, DPE, SPCP,LAIE, F-91191 Gif Sur Yvette, France
来源
关键词
D O I
10.1007/s002160051343
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Elemental and isotopic determination of americium and curium in spent nuclear fuels is necessary to validate neutronic calculation codes and for nuclear waste disposal purposes. Prior to mass spectrometric analysis, it is mandatory to perform separations in order to eliminate isobaric interferences between U, Pu, Am and Cm. In the spent fuels samples analyzed, a separation of U and Pu has been first realized with an anion-exchange resin. Then a rapid Am/Cm separation has been developed by highperformance liquid chromatography (HPLC) with an online detection using the Am and Cm alpha-emission. The influence of the different parameters on the chromatographic separation are described and discussed. Inductively coupled plasma mass spectrometry (ICP-MS) and thermal-ionization mass spectrometry (TIMS) have been used to measure the isotopic composition of U, Am and Cm and to determine the Am-241/U-238 and Cm-244/U-238 ratios with the double spike isotope dilution method. The measurement procedures and the accuracy and precision of the results obtained with a quadrupole ICP-MS on different spent fuels samples are discussed and compared with those obtained by TIMS, used as a reference technique.