Hygrothermal Analysis of Masonry Wall with Reed Boards as Interior Insulation System

被引:5
|
作者
Keskkula, Kadri [1 ]
Aru, Tambet [1 ]
Kiviste, Mihkel [1 ,2 ]
Miljan, Martti-Jaan [1 ]
机构
[1] Estonian Univ Life Sci, Inst Forestry & Rural Engn, Chair Rural Bldg & Water Management, FR Kreutzwaldi 1, EE-51006 Tartu, Estonia
[2] Tallinn Univ Technol, Tartu Coll, Sch Engn, Ehitajate Tee 5, EE-19086 Tallinn, Estonia
关键词
interior insulation; hygrothermal performance; reed insulation; heating cable; PERFORMANCE;
D O I
10.3390/en13205252
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
When the masonry walls of buildings under heritage protection need to be restored and thermally improved, the only option is to use an interior insulation system. This is also the riskiest method of insulating walls in cold climates. Capillary active interior insulation systems have been proven to be the most reliable, minimizing the risk of mold growth and decay caused by condensation. They have also been proven to be less risky in wind-driven rain. The building studied is situated in a heritage-conservation area in downtown Tartu, Estonia, and therefore cannot be insulated from the exterior. This paper compares the hygrothermal performance of four different interior insulation systems with and without a heating cable and vapor barrier. In the first case, Isover Vario KM Duplex UV was placed between reed panels. In the second case, reed panels were used without the vapor barrier. Data loggers were applied between the reed panels and the original wall and inside the room to measure temperature and relative humidity in one-hour intervals. Exterior temperature and relative humidity values were taken from the Estonian University of Life Sciences Institute of Technology weather service station. In addition to the measurements taken in the case study building, calculations were made using heat-air-moisture (HAM) Delphin software to simulate the situation. The use of a smart vapor retarder (Isover Vario KM Duplex UV) with reed panels in the interior insulation system reduced the relative humidity level inside the wall. The vapor retarder improved the drying-potential compared to the interior insulation system without the vapor barrier.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Hygrothermal performance of a masonry wall retrofitted with interior insulation
    Saïd, MNA
    Demers, RG
    McSheffrey, LL
    [J]. RESEARCH IN BUILDING PHYSICS, 2003, : 445 - 454
  • [2] Hygrothermal performance of a masonry wall retrofitted with interior insulation, the analysis of temperature and moisture distribution in wall construction
    Pinigiene, J.
    Susinskas, S.
    [J]. 11TH INTERNATIONAL CONFERENCE ON INTELLIGENT TECHNOLOGIES IN LOGISTICS AND MECHATRONICS SYSTEMS (ITELMS'2016), 2016, : 125 - 129
  • [3] Measuring the Hygrothermal Performance of an Interior Insulation made of Woodfibre Boards
    Wegerer, Paul
    Nackler, Joachim Nathanael
    Bednar, Thomas
    [J]. 6TH INTERNATIONAL BUILDING PHYSICS CONFERENCE (IBPC 2015), 2015, 78 : 1478 - 1483
  • [4] Interior insulation for wall retrofitting - A probabilistic analysis of energy savings and hygrothermal risks
    Vereecken, Evy
    Van Gelder, Liesje
    Janssen, Hans
    Roels, Staf
    [J]. ENERGY AND BUILDINGS, 2015, 89 : 231 - 244
  • [5] Hygrothermal behavior of a massive wall with interior insulation during wetting
    Guizzardi, M.
    Derome, D.
    Vonbank, R.
    Carmeliet, J.
    [J]. BUILDING AND ENVIRONMENT, 2015, 89 : 59 - 71
  • [6] Sensitivity analysis of the hygrothermal behaviour of homogeneous masonry constructions: Interior insulation, rainwater infiltration and hydrophobic treatment
    Calle, Klaas
    Van Den Bossche, Nathan
    [J]. JOURNAL OF BUILDING PHYSICS, 2021, 44 (06) : 510 - 538
  • [7] Hygrothermal assessment of diffusion open insulation systems for interior retrofitting of solid masonry walls
    Jensen, N. F.
    Odgaard, T. R.
    Bjarlov, S. P.
    Andersen, B.
    Rode, C.
    Moller, E. B.
    [J]. BUILDING AND ENVIRONMENT, 2020, 182
  • [8] Hygrothermal performance study of an innovative interior thermal insulation system
    Pavlik, Zbysek
    Cerny, Robert
    [J]. APPLIED THERMAL ENGINEERING, 2009, 29 (10) : 1941 - 1946
  • [9] Hygrothermal modelling of masonry blocks filled with thermal insulation
    Nagy, Balazs
    [J]. 8TH SCIENTIFIC-TECHNICAL CONFERENCE ON MATERIAL PROBLEMS IN CIVIL ENGINEERING (MATBUD'2018), 2018, 163
  • [10] Interior insulation - Experimental investigation of hygrothermal conditions and damage evaluation of solid masonry fa ades in a listed building
    Odgaard, Tommy
    Bjarlov, Soren Peter
    Rode, Carsten
    [J]. BUILDING AND ENVIRONMENT, 2018, 129 : 1 - 14