Determination of trace amounts of Se(IV) by hydride generation atomic fluorescence spectrometry after solid-phase extraction using magnetic multi-walled carbon nanotubes

被引:42
|
作者
Wang, Yang [1 ]
Xie, Jing [1 ]
Wu, Yichun [1 ]
Hu, Xiaoya [1 ]
Yang, Chun [1 ]
Xu, Qin [1 ]
机构
[1] Yangzhou Univ, Sch Chem & Chem Engn, Yangzhou 225002, Peoples R China
基金
中国国家自然科学基金;
关键词
Fe3O4; Multi-wall carbon nanotubes; Solid-phase extraction; Hydride generation atomic fluorescence spectrometry; Se(IV); ENVIRONMENTAL WATER; SELENIUM; SAMPLES; PRECONCENTRATION; SPECIATION; REMOVAL; SE; MICROEXTRACTION; ADSORPTION; BEVERAGE;
D O I
10.1016/j.talanta.2013.03.014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive and simple method using magnetic multi-walled carbon nanotubes, as an adsorbent, has been successfully developed for extraction and preconcentration trace amounts of Se(IV) with detection by hydride generation atomic fluorescence spectrometry. The prepared nanoparticles were confirmed by Fourier transform infrared spectra, X-ray diffraction spectrometry, vibrating sample magnetometry, and transmission electron microscopy. These magnetic nanocomposites can be easily dispersed in aqueous samples and retrieved by the application of external magnetic field via a piece of permanent magnet, The main factors affecting the signal intensity such as sample pH value, adsorbent amount, eluent concentration and volume, sample volume, and coexisting ions have been investigated and established. The absorbent could be repeatedly used at least 100 times. The enhancement factor of the proposed method for Se(IV) was 100. The method had a linear calibration plot in the range from 0.05 to 10.0 mu g L-1 with a standard deviation of 23% at 0.5 mu g L-1 (n=11). The limit of detection was as low as 0.013 mu g Accuracy of the method was evaluated by the analysis of water samples and certified reference materials. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:123 / 128
页数:6
相关论文
共 50 条
  • [1] Magnetic dispersive solid phase extraction using modified magnetic multi-walled carbon nanotubes combined with electrothermal atomic absorption spectrometry for the determination of selenium
    Firouzabadi, Zahra Dehghani
    Dadfarnia, Shayessteh
    Shabani, Ali Mohammad Haji
    Ehrampoush, Mohammad Hassan
    Tafti, Elaheh Nourbala
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2018, 98 (06) : 555 - 569
  • [2] Magnetic solid-phase extraction based on magnetic multi-walled carbon nanotubes for the determination of phthalate monoesters in urine samples
    Rastkari, Noushin
    Ahmadkhaniha, Reza
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1286 : 22 - 28
  • [3] Magnetic nanoparticles modified with polydimethylsiloxane and multi-walled carbon nanotubes for solid-phase extraction of fluoroquinolones
    Xu, Shen
    Jiang, Cheng
    Lin, Yuexin
    Jia, Li
    MICROCHIMICA ACTA, 2012, 179 (3-4) : 257 - 264
  • [4] Magnetic nanoparticles modified with polydimethylsiloxane and multi-walled carbon nanotubes for solid-phase extraction of fluoroquinolones
    Shen Xu
    Cheng Jiang
    Yuexin Lin
    Li Jia
    Microchimica Acta, 2012, 179 : 257 - 264
  • [5] Preconcentration of heavy metal ions on magnetic multi-walled carbon nanotubes using magnetic solid-phase extraction and determination in vegetable samples by electrothermal atomic absorption spectrometry: Box–Behnken design
    Sara Khodadadi
    Elahe Konoz
    Ali Niazi
    Ali Ezabadi
    Chemical Papers, 2022, 76 : 6735 - 6751
  • [6] Determination of Organophosphate Esters in Water Samples Using Gas Chromatography-Mass Spectrometry and Magnetic Solid-Phase Extraction Based on Multi-Walled Carbon Nanotubes
    Wang, Xiyue
    Tian, Yuanyuan
    Lian, Lili
    Zhang, Hao
    Zhu, Bo
    Gao, Wenxiu
    Lou, Dawei
    LC GC EUROPE, 2021, 34 (10) : 410 - +
  • [7] Preconcentration of nickel in multi-walled carbon nanotubes pretreated with potassium permanganate for use as solid-phase extraction adsorbent and determination by flame atomic absorption spectrometry
    Zhou, Qingxiang
    Bai, Huahua
    Xiao, Junping
    ATOMIC SPECTROSCOPY, 2007, 28 (04) : 150 - 155
  • [8] Solid-phase Extraction on Magnetic Multi-walled Carbon Nanotubes Coupled with Flame Atomic Absorption Spectrometry for Determining Lead and Cadmium in Traditional Chinese Medicine
    Qin, Gui Fang
    Jiang, Meng Yi
    Mei, Hou Shu
    Rong, Yao Ke
    Ma, Jing Jun
    JOURNAL OF THE CHEMICAL SOCIETY OF PAKISTAN, 2015, 37 (02): : 272 - 276
  • [9] Multi-residue determination of pesticides in water using multi-walled carbon nanotubes solid-phase extraction and gas chromatography-mass spectrometry
    Wang, Shuo
    Zhao, Peng
    Min, Guang
    Fang, Guozhen
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1165 (1-2) : 166 - 171
  • [10] Multi-walled carbon nanotubes as a solid-phase extraction adsorbent for the determination of chlorophenols in environmental water samples
    Cai, YQ
    Cai, YE
    Mou, SF
    Lu, YQ
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1081 (02) : 245 - 247