Influence of envelope and partition characteristics on the space cooling of high-rise residential buildings in Hong Kong

被引:43
|
作者
Bojic, M [1 ]
Yik, F [1 ]
Wan, K [1 ]
Burnett, J [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Kowloon, Hong Kong, Peoples R China
关键词
thermal insulation; concrete; cooling; simulations;
D O I
10.1016/S0360-1323(01)00045-2
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Nowadays, many apartments in residential buildings in Hong Kong are equipped with air-conditioners to provide comfort cooling for the living, dining and bedrooms, Air-conditioners serving the living and dining rooms would be operated mostly in the evenings and sometimes during daytime as well, but those serving the bedrooms could remain operating overnight. Other rooms, such as bathrooms and kitchens, will not normally be air-conditioned. The paper describes a study into the influence of the building envelope construction on the space cooling loads in residential buildings. The yearly cooling loads of apartments were predicted by using HTB2, a detailed building heat transfer simulation program. The study includes modifications to the base-line characteristics of walls and doors of two typical apartments. The modified walls have an additional 50 mm thick thermal insulation and, or a thickness of up to 400 min of concrete. Modified doors have an additional 38 mm thick thermal insulation. The simulation predictions indicate that the highest reduction in the yearly cooling load could be obtained when the modified walls and doors were used at suitable locations. In addition, the study results show that the yearly cooling load would increase when the thermal insulation was applied to external walls without increasing the thickness of the concrete layer, and when the concrete layer was thickened but Without addition of insulation. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:347 / 355
页数:9
相关论文
共 50 条
  • [1] Influence of thermal insulation position in building envelope on the space cooling of high-rise residential buildings in Hong Kong
    Bojic, M
    Yik, F
    Sat, P
    [J]. ENERGY AND BUILDINGS, 2001, 33 (06) : 569 - 581
  • [2] Investigations of cooling loads in high-rise residential buildings in Hong Kong
    Bojic, M
    Yik, F
    Wan, K
    Burnett, J
    [J]. THERMAL SCIENCES 2000, 2000, : 505 - 510
  • [3] Investigation of cooling loads in high-rise residential buildings in Hong Kong
    Bojic, M
    Yik, F
    Wan, K
    Burnett, J
    [J]. STROJNISKI VESTNIK-JOURNAL OF MECHANICAL ENGINEERING, 2001, 47 (08): : 491 - 496
  • [4] Cooling energy evaluation for high-rise residential buildings in Hong Kong
    Bojic, M
    Yik, F
    [J]. ENERGY AND BUILDINGS, 2005, 37 (04) : 345 - 351
  • [5] The influence of envelope characteristics to the energy behaviour of high-rise residential buildings
    Yik, F
    Bojic, M
    Wan, K
    [J]. ADVANCES IN BUILDING TECHNOLOGY, VOLS I AND II, PROCEEDINGS, 2002, : 1289 - 1296
  • [6] BUILDING IMPLEMENTATION IN HIGH-RISE RESIDENTIAL BUILDINGS IN HONG KONG
    Lau, Wai Kin
    Ho, Daneiel Chi Wing
    [J]. OPEN HOUSE INTERNATIONAL, 2011, 36 (01) : 25 - 34
  • [7] Impact of Window Operation Behaviours on Cooling Load of High-rise Residential Buildings in Hong Kong
    Du, Jia
    Pan, Wei
    [J]. PROCEEDINGS OF BUILDING SIMULATION 2019: 16TH CONFERENCE OF IBPSA, 2020, : 2403 - 2410
  • [8] Energy performance of windows in high-rise residential buildings in Hong Kong
    Bojic, M
    Yik, F
    Sat, P
    [J]. ENERGY AND BUILDINGS, 2002, 34 (01) : 71 - 82
  • [9] The airflow around and inside high-rise residential buildings in Hong Kong
    Bojic, M
    Yik, F
    Burnett, J
    [J]. ADVANCES IN BUILDING TECHNOLOGY, VOLS I AND II, PROCEEDINGS, 2002, : 1331 - 1338
  • [10] Application of switchable glazing to high-rise residential buildings in Hong Kong
    Yik, F
    Bojic, M
    [J]. ENERGY AND BUILDINGS, 2006, 38 (05) : 463 - 471