Efficiency improvement and in vivo estimation of externally-coupled transcutaneous energy transmission system for a totally implantable artificial heart

被引:0
|
作者
Shiba, K [1 ]
Shu, E [1 ]
Koshiji, K [1 ]
Tsukahara, K [1 ]
Tsuchimoto, K [1 ]
Ohu-mi, T [1 ]
Nakamura, T [1 ]
Endo, S [1 ]
Masuzawa, T [1 ]
Tatsumi, E [1 ]
Taenaka, Y [1 ]
Takano, H [1 ]
机构
[1] Sci Univ Tokyo, Noda, Chiba 278, Japan
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In order to enhance the implantability of the externally-coupled transcutaneous energy transmission system (ECTETS), efficiencies in various parts of the circuit system were improved to reduce heat dissipation. As a result. a DC-to-DC energy transmission efficiency of 85% or more was obtained in an in vitro experiment conducted at a power output of 19W. In the in vivo measurement of this improved ECTETS with the internal coil and the rectifier circuit implanted under the skin of a living goad, a DC-to-DC energy transmission efficiency of 82% or more was obtained. Fluctuation of efficiency due to movement of the body was found to be less than 0.5%. when this improved ECTETS is used with die totally implantable electrohydraulic artificial heart with an overflow mock circulatory system connected as a load. the pump output flow at a changing heart rate was found to be 4.4-7.0L/min (50-110bpm). For continuous operation at 70bpm, the DC-to-DC energy transmission efficiency was 81% or more, the pump output flow was 6.2L/min, and the temperature in the part of implantation was lower than 41 degrees C, a temperature that can hardly affect a living body.
引用
收藏
页码:2503 / 2505
页数:3
相关论文
共 28 条
  • [1] Improvement in magnetic field immunity of externally-coupled transcutaneous energy transmission system for a totally implantable artificial heart
    Yamamoto, Takahiko
    Koshiji, Kohji
    Homma, Akihiko
    Tatsumi, Eisuke
    Taenaka, Yoshiyuki
    JOURNAL OF ARTIFICIAL ORGANS, 2008, 11 (04) : 238 - 240
  • [2] Improvement in magnetic field immunity of externally-coupled transcutaneous energy transmission system for a totally implantable artificial heart
    Takahiko Yamamoto
    Kohji Koshiji
    Akihiko Homma
    Eisuke Tatsumi
    Yoshiyuki Taenaka
    Journal of Artificial Organs, 2008, 11 : 238 - 240
  • [3] Transcutaneous Energy Transmission System for a Totally-Implantable Artificial Heart in case Using External Battery
    Yamamoto, T.
    Koshiji, K.
    Nawa, Y.
    Ikeda, Y.
    Yanagi, M.
    Homma, A.
    Tatsumi, E.
    Taenaka, Y.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 3151 - +
  • [4] Development of Unified Transcutaneous Transformer for Energy and Information Transmission for a Totally-Implantable Artificial Heart
    Yamamoto, T.
    Koshiji, K.
    Homma, A.
    Tatsumi, E.
    Taenaka, Y.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 10: BIOMATERIALS, CELLULAR AND TISSUE ENGINEERING, ARTIFICIAL ORGANS, 2009, 25 (10): : 264 - +
  • [5] Transcutaneous energy and information transmission system for a totally implantable artificial heart - evaluation on information transmission characteristics using unified transformer -
    Tokyo University of Science, 2641 Yamazaki, Noda-shi, Chiba, Tokyo 278-8510, Japan
    不详
    IEEJ Trans. Electron. Inf. Syst., 1600, 6 (1176-1177):
  • [6] Transcutaneous Energy Transmission System for a Totally Implantable Artificial Heart Using a Two-Wire Archimedean Spiral Coil
    Okinaga, Tomoki
    Yamamoto, Takahiko
    Koshiji, Kohji
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 5407 - 5410
  • [7] A transcutaneous energy transmission system with rechargeable internal back-up battery for a totally implantable total artificial heart
    Shiba, K
    Shu, EM
    Koshiji, K
    Tsukahara, K
    Nakamura, T
    Masuzawa, T
    Tatsumi, E
    Taenaka, Y
    Takano, H
    ASAIO JOURNAL, 1999, 45 (05) : 466 - 470
  • [8] New structure transcutaneous transformer for totally implantable artificial heart system
    Fok, FC
    Jet, TK
    Lingyin, Z
    ELECTRONICS LETTERS, 1999, 35 (02) : 107 - 108
  • [9] Transcutaneous optical information transmission system for a totally implantable artificial heart - Reduction of optical crosstalk by using polarizer
    Yamamoto, Takahiko
    Koshiji, Kohji
    IEEJ Transactions on Electronics, Information and Systems, 2012, 132 (07) : 1202 - 1203
  • [10] Coupling and Compensation Analysis of Transcutaneous Energy Transmission for Implantable Artificial Heart
    Chen, Haiyan
    Jia, Wenyan
    Yang, Qingxin
    Xu, Guizhi
    Liu, Xiaoyu
    Sun, Mingui
    2009 35TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 2009, : 266 - +