Investigation of indoor chemical pollutants and ventilation rate in Japanese houses

被引:0
|
作者
Mitamura, T [1 ]
Yoshino, H [1 ]
Osawa, H [1 ]
Kuwasawa, Y [1 ]
Ikeda, K [1 ]
Watanabe, T [1 ]
Ozaki, A [1 ]
Yanagisawa, Y [1 ]
Kumagai, K [1 ]
机构
[1] Ashikaga Inst Technol, Fac Engn, Ashikaga, Japan
关键词
chemical pollutants; ventilation rate; field measurement; Japanese houses;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper describes the results of measurements of chemical pollutants and ventilation rate in 55 Japanese houses. In this survey, indoor chemical pollutants, indoor thermal environment and ventilation rate were measured during winter and summer. For chemical pollutants, formaldehyde and VOC concentrations in the air, the space of the inside wall were measured. As a result, formaldehyde and VOC concentrations during winter and summer were then observed. Sources of pollutants were estimated by comparing the concentrations at three places, i.e. indoor air, the space of inside wall and the surface of surrounding walls. On the other hand, it was found that the ventilation rate was not sufficient even if the mechanical ventilation system was installed. The relationship between indoor chemical pollutants and ventilation rate is highlighted.
引用
收藏
页码:2258 / 2262
页数:5
相关论文
共 50 条
  • [1] Field investigation of indoor air quality and ventilation characteristics in selected Irish houses
    Guo, LY
    Lewis, J
    Kelly, A
    Lennon, D
    [J]. INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 691 - 697
  • [2] Preliminary Investigation of Indoor Microplastic Concentrations in House Dust in Japanese Residential Houses
    Lim, Eunsu
    Tanaka, Hirofumi
    Ito, Kazuhide
    [J]. 17th International Conference on Indoor Air Quality and Climate, INDOOR AIR 2022, 2022,
  • [3] Field investigation on indoor chemical pollution in temporary houses in sendai city
    Kagi N.
    Yoshino H.
    Hasegawa K.
    Yanagi U., Prof.
    Azuma K.
    Osawa H.
    [J]. 1600, Architectural Institute of Japan (81): : 979 - 985
  • [4] Polyfluorinated telomers in indoor air of Japanese houses
    Liu, Wanyang
    Takahashi, Satoshi
    Sakuramachi, Yui
    Harada, Kouji H.
    Koizumi, Akio
    [J]. CHEMOSPHERE, 2013, 90 (05) : 1672 - 1677
  • [5] Investigation of indoor chemical pollutants and perceived odor in an area with complaints of unpleasant odors
    Peng, Chiung-Yu
    Lan, Cheng-Hang
    Wu, Tzong-Jer
    [J]. BUILDING AND ENVIRONMENT, 2009, 44 (10) : 2106 - 2113
  • [6] Indoor air quality - Chemical pollutants
    Senitkova, I
    [J]. INTERNATIONAL SYMPOSIUM ON AIR CONDITIONING IN HIGH RISE BUILDINGS '2000, PROCEEDINGS, 2000, 2000 (03): : 183 - 185
  • [7] INDOOR RADON IN 3 APARTMENT HOUSES WITH DIFFERENT VENTILATION SYSTEM
    KOKOTTI, H
    SAVOLAINEN, T
    KALLIOKOSKI, P
    REPONEN, T
    RAUNEMAA, T
    [J]. HEALTHY BUILDINGS 88, VOL 2: PLANNING, PHYSICS AND CLIMATE TECHNOLOGY FOR HEALTHIER BUILDINGS, 1988, : 157 - 162
  • [8] Building Design Effect on Indoor Natural Ventilation of Tropical Houses
    Abd Wahab, Izudinshah
    Abd Aziz, Hazri
    Abd Salam, Nur Nasuha
    [J]. INTERNATIONAL JOURNAL OF SUSTAINABLE CONSTRUCTION ENGINEERING AND TECHNOLOGY, 2019, 10 (01): : 23 - 33
  • [9] Investigation of Indoor Air Quality in Houses of Macedonia
    Vilcekova, Silvia
    Apostoloski, Ilija Zoran
    Meciarova, L'udmila
    Burdova, Eva Kridlova
    Kisel'ak, Jozef
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2017, 14 (01)
  • [10] Annual characteristics of ventilation and indoor air quality in detached houses using a simulation method with Japanese daily schedule model
    Hayashi, M
    Enai, M
    Hirokawa, Y
    [J]. BUILDING AND ENVIRONMENT, 2001, 36 (06) : 721 - 731