Improving liquid chromatography-tandem mass spectrometry determination of polycarboxylic acids in human urine by chemical derivatization. Comparison of o-benzyl hydroxylamine and 2-picolyl amine

被引:21
|
作者
Gomez-Gomez, Alex [1 ,2 ]
Soldevila, Angie [1 ]
Pizarro, Nieves [1 ]
Andreu-Fernandez, Vicente [3 ]
Pozo, Oscar J. [1 ]
机构
[1] Hosp Mar, Integrat Pharmacol & Syst Neurosci Grp FINS, IMIM, Doctor Aiguader 88, Barcelona, Spain
[2] UPF, CEXS, Doctor Aiguader 88, Barcelona, Spain
[3] Hosp Clin Maternitat, GRIE, Neonatol Unit, BCNatal, Sabino Arana 1, Barcelona 08028, Spain
关键词
LC-MS/MS; Chemical derivatization; o-benzylhydroxyl amine; 2-picolylamine; Method validation; Tricarboxylic acid cycle; ORGANIC-ACIDS; ELECTROSPRAY-IONIZATION; QUANTITATIVE-ANALYSIS; METABOLOMICS; SENSITIVITY; METABOLISM; SAMPLES; PLASMA; CYCLE; HMDB;
D O I
10.1016/j.jpba.2018.10.055
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Due to its high sensitivity and specificity, liquid chromatography-electrospray tandem mass spectrometry (LC-MS/MS) could be considered as the gold-standard in targeted metabolomics. Although LC-MS/MS allows for the direct detection of a large number of molecules, the proper quantification of highly polar compounds such as poly-carboxylic acids in complex matrices like urine is still a challenge. Chemical derivatization offers a suitable way to improve chromatographic behavior and sensitivity for these compounds. Several derivatizing agents have been proposed for the LC-MS/MS determination of carboxylic acids but studies dealing with their comparison in challenging scenarios are scarce. Here we present the evaluation of two different derivatization agents; o-benzylhydroxyl amine (oBHA) and 2-picolyl amine (2-PA); for the quantification of the (poly)-carboxylic acids belonging to the tricarboxylic acid cycle in urine. The suitability of both derivatizating agents was compared by validation of the two approaches. Derivatization with oBHA showed important advantages against 2-PA derivatization such as (i) providing better sensitivity, (ii) more stable derivatives and (iii) allowing for the proper validation of a larger number of analytes. Moreover, while 2-PA derivatization failed in the determination of the target analytes in some stored urine samples, oBHA derivatization successfully allowed for their appropriate determination in the same samples. A comparison between the concentrations obtained using oBHA derivatization and those provided by an external laboratory using UV and GC-MS detection revealed a satisfactory agreement between both results. Additionally, the concentrations obtained by the oBHA method for a set of 38 urines are in agreement with those previously reported in the literature. As a conclusion, our results show that the use of oBHA is preferred against 2-PA for the detection and quantification of (poly)-carboxylic acids in urine. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:382 / 394
页数:13
相关论文
共 50 条
  • [1] A novel method of liquid chromatography-tandem mass spectrometry combined with chemical derivatization for the determination of ribonucleosides in urine
    Li, Shangfu
    Jin, Yibao
    Tang, Zhi
    Lin, Shuhai
    Liu, Hongxia
    Jiang, Yuyang
    Cai, Zongwei
    ANALYTICA CHIMICA ACTA, 2015, 864 : 30 - 38
  • [2] Determination of phenethyl isothiocyanate in human plasma and urine by ammonia derivatization and liquid chromatography-tandem mass spectrometry
    Ji, Y
    Morris, ME
    ANALYTICAL BIOCHEMISTRY, 2003, 323 (01) : 39 - 47
  • [3] Determination of mildronate in human plasma and urine by liquid chromatography-tandem mass spectrometry
    Lv, Yun-Feng
    Hu, Xin
    Bi, Kai-Shun
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 852 (1-2): : 35 - 39
  • [4] Determination of Benzotriazoles and Benzothiazoles in Human Urine by Liquid Chromatography-Tandem Mass Spectrometry
    Asimakopoulos, Alexandros G.
    Bletsou, Anna A.
    Wu, Qian
    Thomaidis, Nikolaos S.
    Kannan, Kurunthachalam
    ANALYTICAL CHEMISTRY, 2013, 85 (01) : 441 - 448
  • [5] Determination of faropenem in human plasma and urine by liquid chromatography-tandem mass spectrometry
    Gao, Shouhong
    Chen, Wansheng
    Tao, Xia
    Miao, Haijun
    Yang, Shaolin
    Wu, Rong
    BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (01) : 5 - 12
  • [6] Simultaneous determination of all aminobutyric acids by chiral derivatization and liquid chromatography-tandem mass spectrometry
    Eiji Sugiyama
    Mao Nakamura
    Hajime Mizuno
    Aogu Furusho
    Kenichiro Todoroki
    Analytical Sciences, 2023, 39 : 463 - 472
  • [7] Simultaneous determination of all aminobutyric acids by chiral derivatization and liquid chromatography-tandem mass spectrometry
    Sugiyama, Eiji
    Nakamura, Mao
    Mizuno, Hajime
    Furusho, Aogu
    Todoroki, Kenichiro
    ANALYTICAL SCIENCES, 2023, 39 (04) : 463 - 472
  • [8] Determination of allopurinol and oxypurinol in human plasma and urine by liquid chromatography-tandem mass spectrometry
    Liu, Xia
    Ni, Xiao-Jia
    Shang, De-Wei
    Zhang, Ming
    Hu, Jin-Qing
    Qiu, Chang
    Luo, Fu-Tian
    Wen, Yu-Guan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 941 : 10 - 16
  • [9] Sensitive Liquid Chromatography-Tandem Mass Spectrometry Method for the Determination of Olanzapine in Human Urine
    Urdigere, Anil Kumar Rangachar
    Besagarahally, Bhasakra Laxmaiah
    Basavaiah, Kanakapura
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2012, 37 (05) : 1381 - 1387
  • [10] Comparison of 3-nitrophenylhydrazine, O-benzyl hydroxylamine, and 2-picolylamine derivatizations for analysis of short-chain fatty acids through liquid chromatography coupled with tandem mass spectrometry
    Nagatomo, Ryosuke
    Ichikawa, Aoi
    Kaneko, Haruki
    Inoue, Koichi
    ANALYTICAL SCIENCES, 2024, 40 (05) : 843 - 851