Assessment of high-frequency neonatal ventilator performances

被引:28
|
作者
Jouvet, P
Hubert, P
Isabey, D
Pinquier, D
Dahan, E
Cloup, M
Harf, A
机构
[1] HOP HENRI MONDOR,SERV PHYSIOL,INSERM U296,CRETEIL,FRANCE
[2] HOP NECKER ENFANTS MALAD,SERV REANIMAT PEDIAT POLYVALENTE,F-75743 PARIS 15,FRANCE
关键词
high-frequency ventilation; pediatric intensive care;
D O I
10.1007/s001340050318
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To assess the efficacy and reliability of neonatal high-frequency ventilators. Design: Bench evaluation of neonatal high-frequency ventilators. Setting: Physiology department and university hospital neonatal intensive care unit. Interventions: HFV-Babylog 8000 (Drager Medical), OHF 1 (Dufour), and SensorMedics 3100A (SensorMedics) ventilators were connected to a neonatal test-lung. Tidal volume, peak-to-peak pressure amplitude, and mean airway pressure were measured for several ventilator settings, endotracheal tube sizes, and lung compliances. Measurements and results: Increasing peak-to-peak pressure resulted in a linear increase in tidal volume delivery in the 0-30% range of maximum amplitude. No significant increase in tidal volume was observed with the HFV-Babylog 8000 when pressure amplitude was above 50%. The maximum tidal volume delivered was substantially smaller with the HFV-Babylog 8000 than with the OHF 1 or SensorMedics 3100A. Tidal volume increased with endotracheal tube size with all three ventilators. Increasing test-lung compliance resulted in lower tidal volumes only with OHF 1. Decreasing mean airway pressure was responsible for a decrease in tidal volume delivery with HFV-Babylog 8000. Conclusion: We found that under our test conditions two of the three ventilators delivered adequate tidal volumes at the usual frequency of 15 Hz, regardless of the size of the endotracheal tube and of the mechanical properties of the respiratory system. When lung compliance increased or mean airway pressure decreased, both of which are common events during the recovery phase of hyaline membrane disease, we found that the intrinsic properties of two of the ventilators tested were responsible for a decrease in tidal volume. This decrease may account for some cases of heretofore unexplained hypercapnia.
引用
收藏
页码:208 / 213
页数:6
相关论文
共 50 条
  • [1] Assessment of high-frequency neonatal ventilator performances
    P. Jouvet
    P. Hubert
    D. Isabey
    D. Pinquier
    E. Dahan
    M. Cloup
    A. Harf
    [J]. Intensive Care Medicine, 1997, 23 : 208 - 213
  • [2] ASSESSMENT OF NEONATAL VENTILATOR PERFORMANCES
    JOUVET, P
    HUBERT, P
    JARREAU, PH
    LOFASO, F
    CLOUP, M
    HARF, A
    [J]. INTENSIVE CARE MEDICINE, 1995, 21 (09) : 753 - 758
  • [3] MANAGEMENT OF MALIGNANT AIR LEAK IN A CHILD WITH A NEONATAL HIGH-FREQUENCY OSCILLATORY VENTILATOR
    MAYES, TC
    JEFFERSON, LS
    DAVID, Y
    LOUIS, PT
    FORTENBERRY, JD
    [J]. CHEST, 1991, 100 (01) : 263 - 264
  • [4] HIGH-FREQUENCY VENTILATOR - PRINCIPLES OF USE
    MACNEIL, A
    BISERA, J
    WEIL, MH
    [J]. CRITICAL CARE MEDICINE, 1981, 9 (03) : 190 - 190
  • [5] Assessment of neonatal ventilation during high-frequency oscillatory ventilation
    Sturtz, Wendy J.
    Touch, Suzanne M.
    Locke, Robert G.
    Greenspan, Jay S.
    Shaffer, Thomas H.
    [J]. PEDIATRIC CRITICAL CARE MEDICINE, 2008, 9 (01) : 101 - 104
  • [6] A SIMPLE FLUERIC HIGH-FREQUENCY JET VENTILATOR
    BUNEGIN, L
    BORG, U
    SJOSTRAND, UH
    [J]. ANESTHESIA AND ANALGESIA, 1983, 62 (01): : 122 - 122
  • [7] A NEW AND UNIQUE HIGH-FREQUENCY OSCILLATORY VENTILATOR
    NULL, D
    ACKERMAN, N
    KUEHL, T
    ESCOBEDO, M
    JENSEN, R
    DELEMOS, R
    [J]. CLINICAL RESEARCH, 1984, 32 (05): : A918 - A918
  • [8] Benchmark of a high-frequency jet ventilator, the Mistral®
    Gueret, G.
    Rossignol, B.
    Ferrec, G.
    Arvieux, C. -C.
    Bourgain, J. -L.
    [J]. ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2006, 25 (10): : 1030 - 1033
  • [9] Benchmark of a high-frequency jet ventilator, the Monsoon™
    Gueret, G.
    Touffet, L.
    Arvieux, C. -C.
    Bourgain, J. -L.
    [J]. ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2010, 29 (11): : 821 - 825
  • [10] A SIMPLE FLUERIC HIGH-FREQUENCY JET VENTILATOR
    CALKINS, JM
    WATERSON, CK
    HAMEROFF, SR
    HARRIS, TR
    JONES, JF
    [J]. ANESTHESIA AND ANALGESIA, 1982, 61 (02): : 138 - 141