Performance of concrete structures retrofitted with fibre reinforced polymers

被引:65
|
作者
Sheikh, SA [1 ]
机构
[1] Univ Toronto, Dept Civil Engn, Toronto, ON M5S 1A4, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
beams; columns; ductility; fibre reinforced polymers (FRP); repair; retrofitting; seismic; slabs;
D O I
10.1016/S0141-0296(02)00025-1
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Retrofitting with fibre reinforced polymers (FRP) to strengthen and repair damaged structures is a relatively new technique. In an extensive research program underway at the University of Toronto, application of FRP in concrete structures is being investigated for its effectiveness in enhancing structural performance both in terms of strength and ductility. The structural components tested so far include slabs, beams, columns and bridge culverts. Research on columns has particularly focussed on improving their seismic resistance by confining them with FRP. All the specimens tested can be considered as full-scale to two-third scale models of the structural components generally used in practice. Results so far indicate that retrofitting with FRP offers an attractive alternative to the traditional techniques. In many circumstances, it can provide the most economical (and superior) solution for a structural rehabilitation problem. Selected results from experimental and analytical research are presented in this paper. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:869 / 879
页数:11
相关论文
共 50 条
  • [1] Efficient finite element modelling of reinforced concrete beams retrofitted with fibre reinforced polymers
    Barbato, M.
    [J]. COMPUTERS & STRUCTURES, 2009, 87 (3-4) : 167 - 176
  • [2] Durability of fibre-reinforced polymers in concrete structures
    Kalman, Tanja
    Bjegovic, Dubravka
    Sigmund, Vladimir
    [J]. GRADEVINAR, 2010, 62 (07): : 611 - 619
  • [3] Durability of fibre reinforced polymers used in concrete structures
    Homam, SM
    Sheikh, SA
    Collins, P
    Pernica, G
    Daoud, J
    [J]. ADVANCED COMPOSITE MATERIALS IN BRIDGES AND STRUCTURES, 2000, : 751 - 758
  • [4] Technical guidelines on the use of Fibre Reinforced Polymers for strengthening of reinforced concrete structures
    Chhabra, Y
    [J]. 8th International Conference on Inspection Appraisal Repairs & Maintenance of Structures, 2003, : 219 - 228
  • [5] Performance evaluation of structures with reinforced concrete columns retrofitted with steel jacketing
    Villar-Salinas, Sergio
    Guzman, Andres
    Carrillo, Julian
    [J]. JOURNAL OF BUILDING ENGINEERING, 2021, 33
  • [6] Bond between fibre reinforced concrete and fibre reinforced polymers
    Harryson, Peter
    [J]. MATERIALS AND STRUCTURES, 2011, 44 (01) : 377 - 389
  • [7] Reliablity analysis of bridge beams retrofitted with fibre reinforced polymers
    Pham, Huy Binh
    Al-Mahaidi, Riadh
    [J]. COMPOSITE STRUCTURES, 2008, 82 (02) : 177 - 184
  • [8] Finite element modeling of concrete structures reinforced with internal and external fibre-reinforced polymers
    Nour, Ali
    Massicotte, Bruno
    Yildiz, Emre
    Koval, Viacheslav
    [J]. CANADIAN JOURNAL OF CIVIL ENGINEERING, 2007, 34 (03) : 340 - 354
  • [9] Investigation on tension and bonding behaviour of basalt fibre reinforced polymers in concrete structures
    Wolf, Benjamin
    Glomb, Daniel
    Kustermann, Andrea
    Dauberschmidt, Christoph
    [J]. BETON- UND STAHLBETONBAU, 2019, 114 (07) : 454 - 464
  • [10] Axial compressive behaviour of corroded steel reinforced concrete columns retrofitted with a basalt fibre reinforced polymer-ultrahigh performance concrete jacket
    Yang, Xu
    Zhang, Bing
    Zhou, Ao
    Wei, Huinan
    Liu, Tiejun
    [J]. COMPOSITE STRUCTURES, 2023, 304