Analysis of power factor in variable flux reluctance machines with MMF-permeance model

被引:3
|
作者
Huang, Liren [1 ]
Feng, Jianghua [2 ]
Guo, Shuying [2 ]
Shi, Junxu [2 ]
Zhu, Zi Qiang [1 ]
机构
[1] Univ Sheffield, Elect Machines & Drives Grp, Sheffield S1 3JD, S Yorkshire, England
[2] CRRC Zhuzhou Inst Co Ltd, Shidai Rd, Zhuzhou, Hunan, Peoples R China
关键词
stators; air gaps; magnetic flux; rotors; finite element analysis; permanent magnet machines; power factor; reluctance machines; rotor-pole arc; rotor-pole number; armature windings; salient rotor; 6-stator-pole; 4-rotor-pole VFRM; MMF-permeance model; variable flux reluctance machines; simplified analytical model; predictable ratios; rotor permeance ratio; stator; rotor-pole ratio; low-power factor; AC; DC winding ampere turns ratio; DC; AC winding ampere turns ratio; NO PERMANENT-MAGNETS; TORQUE PRODUCTION; HYBRID; SYSTEMS; DRIVES;
D O I
10.1049/iet-epa.2018.5301
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This study investigates the underlying mechanism of low-power factor issue of variable flux reluctance machines (VFRMs) from the perspective of magneto-motive force (MMF)-permeance model. On the basis of a simplified analytical model, the relationship between the design parameters and the power factor is identified and systematically summarised into three predictable ratios: the rotor permeance ratio, stator/rotor-pole ratio and DC/AC winding ampere turns ratio. Specifically, the smaller the rotor-pole arc, the air-gap length, the rotor-pole number and the AC/DC winding ampere turns ratio are, the higher the power factor will be. In addition, the weak coupling between the field and armature windings caused by the modulation effect of the salient rotor is responsible for the low-power factor issue of VFRMs, regardless of the control scheme, winding configuration or saturation effect. A 6-stator-pole/4-rotor-pole VFRM is prototyped and tested for verification.
引用
收藏
页码:614 / 624
页数:11
相关论文
共 50 条
  • [1] Understanding Switched-Flux Machines: A MMF-Permeance Model and Magnetic Equivalent Circuit Approach
    Eguren, Imanol
    Almandoz, Gaizka
    Egea, Aritz
    Badiola, Xabier
    Urdangarin, Ander
    IEEE ACCESS, 2022, 10 : 6909 - 6928
  • [2] Analysis of Torque Production in Variable Flux Reluctance Machines
    Huang, L. R.
    Feng, J. H.
    Guo, S. Y.
    Shi, J. X.
    Chu, W. Q.
    Zhu, Z. Q.
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2017, 32 (04) : 1297 - 1308
  • [3] Analysis and Minimization of Torque Ripple for Variable Flux Reluctance Machines
    Bao, J.
    Gysen, B. L. J.
    Boynov, K.
    Paulides, J. J. H.
    Bastiaens, K.
    Lomonova, E. A.
    2017 IEEE INTERNATIONAL ELECTRIC MACHINES AND DRIVES CONFERENCE (IEMDC), 2017,
  • [4] Analysis of Variable Flux Reluctance Machines Using Hybrid Analytical Modelling
    Bao, Jing
    Aleksandrov, Samuil R.
    Gysen, Bart L. J.
    Lomonova, Elena A.
    2018 THIRTEENTH INTERNATIONAL CONFERENCE ON ECOLOGICAL VEHICLES AND RENEWABLE ENERGIES (EVER), 2018,
  • [5] Comparison of Torque Production and Design of Switched Reluctance and Variable Flux Reluctance Machines
    Dexter, James
    Huang, Liren
    Zhu, Z. Q.
    Vinamata, Xavier
    2018 21ST INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2018, : 1924 - 1929
  • [6] Power factor analysis of transverse flux permanent machines
    Zhao, Y
    Chai, JY
    ICEMS 2005: Proceedings of the Eighth International Conference on Electrical Machines and Systems, Vols 1-3, 2005, : 450 - 453
  • [7] Analysis of Power Factor of Stator DC Excited Vernier Reluctance Machines
    Jia, S.
    Qu, R.
    Li, J.
    2015 IEEE MAGNETICS CONFERENCE (INTERMAG), 2015,
  • [8] Geometric Optimization Of Variable Flux Reluctance Machines For Full Electric Vehicles
    Zuurbier, M. M. J.
    Fahdzyana, C. A.
    Hofman, T.
    Bao, J.
    Lomonova, E. A.
    2019 FOURTEENTH INTERNATIONAL CONFERENCE ON ECOLOGICAL VEHICLES AND RENEWABLE ENERGIES (EVER), 2019,
  • [9] Analysis and Preliminary Design of Variable Flux Reluctance Machines: A Perspective from Working Field Harmonics
    Gu, Xiangpei
    Bianchi, Nicola
    Zhang, Zhuoran
    VEHICLES, 2024, 6 (01): : 571 - 589
  • [10] Comparative Analysis of Cogging Torque Reduction Methods of Variable Flux Reluctance Machines for Electric Vehicles
    Liu, Yang
    Yin, Jinjun
    Gong, Bo
    Yang, Gao
    2017 20TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2017,