Results after surgical treatment of periprosthetic proximal femoral fractures. Osteosynthesis with prosthesis preservation vs. prosthesis change

被引:1
|
作者
Zajonz, Dirk [1 ,2 ,3 ]
Poenick, Cathleen [1 ]
Edel, Melanie [1 ,2 ]
Moebius, Robert [1 ,2 ]
Pfeifle, Christian [1 ,2 ]
Prietzel, Torsten [2 ,3 ]
Roth, Andreas [1 ,2 ]
Fakler, Johannes K. M. [1 ]
机构
[1] Univ Hosp Leipzig, Dept Orthopaed Surg Traumatol & Plast Surg, Leipzig, Germany
[2] ZESBO Ctr Res Musculoskeletal Syst, Leipzig, Germany
[3] Zeisigwald Hosp Bethania, Clin Orthopaed Trauma & Reconstruct Surg, Zeisigwaldstr 101, D-09130 Chemnitz, Germany
关键词
periprosthetic proximal femoral fracture; osteosynthesis; prosthesis change; TOTAL HIP-ARTHROPLASTY; VANCOUVER TYPE B1; REVISION ARTHROPLASTY; FEMUR FRACTURES; PLATE FIXATION; RISK-FACTORS; MANAGEMENT; THA; EPIDEMIOLOGY; REPLACEMENT;
D O I
10.3205/iprs000146
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Periprosthetic fractures (PPF) of the femur close to the hip joint have serious consequences for most geriatric affected patients. In principle, apart from the highly uncommon conservative therapy, there are two therapeutic options. On the one hand, the prosthesis-preserving treatment by means of osteosynthesis using plates and/or cerclages in general is available. On the other hand, a (partial) change of the prosthesis with optionally additive osteosynthesis or a proximal femoral replacement can be performed because of prosthesis loosening or non-reconstructable comminuted fractures as well asmost cemented stem variations. The aim of this retrospective study is the analysis of periprosthetic proximal femoral fractures in the presence of a total hip arthroplasty (THA). The outcome of the operated patients is to be investigated depending on the type of care (osteosynthesis with prosthesis preservation vs. prosthesis change). Material and methods: In a retrospective case analysis, 80 patients with THA and PPF were included. They were divided into two groups. Group I represents the osteosynthetic treatment to preserve the implanted THA (n=42). Group II (n=38) includes those patients who were treated by a change of their endoprosthesis with or without additional osteosynthesis. Specifics of all patients, like gender, age at fracture, interval between fracture and implantation, length of in-patient stay, bodymass index, osteoporosis, corticomedullary index and complications such as infections, re-fracture, loosening, material failure or other complications, were recorded and compared. Furthermore, the patients were re-examined by a questionnaire and the score according to Merle d'Aubigne and Postel. Results: In group I the mean follow-up time was 48.5 +/- 23 months (4 years) whereas group II amounted 32.5 +/- 24.5 months (2.7 years) (p=0.029). Besides, there were significant differences in age (81 +/- 11 years vs. 76 +/- 10 years, p=0.047) and length of in-patient stay (14.5 +/- 8.6 days vs. 18.0 +/- 16.7 days, p=0.014). According to the score of Merle d'Aubigne and Postel, there were significantly better values for the pain in group II with comparable values for mobility and walking ability. Conclusion: The treatment of periprosthetic proximal fractures of the femur is dependent on the classification (Vancouver and Johannsen) and in particular on the prosthetic anchoring as well as the extent of the comminution zone. Older patients and patients with osteoporosis are more frequently treated with an endoprosthesis revision. Patients, who have been treated with an osteosynthesis for preserving their endoprosthesis, showed a shorter length of in-patient stay and fewer complications than people with replacement surgery. In contrast to that, patients with prosthesis revision had better outcomes concerning the score of Merle d'Aubigne and Postel.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Treatment of periprosthetic femoral fractures by effective lengthening of the prosthesis
    Meyer, Christof
    Alt, Volker
    Schroeder, Ludwig
    Heiss, Christian
    Schnettler, Reinhard
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (463) : 120 - 127
  • [2] Treatment of proximal humeral fractures. From conservative to the inverse prosthesis
    Bahrs, C.
    Klopfer, T.
    Scheiderer, S.
    Stoeckle, U.
    TRAUMA UND BERUFSKRANKHEIT, 2014, 16 (01) : 46 - 52
  • [3] Revision osteosynthesis vs. prosthesis after unsuccessful humeral head osteosynthesis
    Schliemann B.
    Theisen C.
    Barz L.
    Weimann A.
    Raschke M.J.
    Obere Extremität, 2016, 11 (4) : 239 - 247
  • [4] Prosthesis after comminuted radial head fractures. Midterm results
    Moghaddam, A.
    Lennert, A.
    Studier-Fischer, S.
    Wentzensen, A.
    Zimmermann, G.
    UNFALLCHIRURG, 2008, 111 (12): : 997 - 1004
  • [5] Periprosthetic fractures. Long-term results after plate osteosynthesis stabilization
    Rupprecht, M.
    Grossterlinden, L.
    Barvencik, F.
    Gebauer, M.
    Briem, D.
    Rueger, J. M.
    Lehmann, W.
    UNFALLCHIRURG, 2008, 111 (10): : 812 - 820
  • [6] Proximal femur fractures.: Results and complications after osteosynthesis with PFN and TGN
    Mueller, M.
    Seitz, A.
    Besch, L.
    Hilgert, R. E.
    Seekamp, A.
    UNFALLCHIRURG, 2008, 111 (02): : 71 - 77
  • [7] Reverse Shoulder Prosthesis for Proximal Humeral Fractures: Primary Treatment vs. Salvage Procedure
    Caldaria, Antonio
    Saccone, Luca
    Biagi, Nicolo
    de Sanctis, Edoardo Giovannetti
    Baldari, Angelo
    Palumbo, Alessio
    Franceschi, Francesco
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (11)
  • [8] Intramedullary nailing vs. locking plate osteosynthesis in proximal humeral fractures. Long-term outcome
    von Rueden, C.
    Trapp, O.
    Hierholzer, C.
    Prohaska, S.
    Wurm, S.
    Buehren, V.
    UNFALLCHIRURG, 2015, 118 (08): : 686 - 692
  • [9] Special prosthesis implant with partial femoral replacement. Operation after periprosthetic femoral fracture and ipsilateral long-stem knee prosthesis and fixed-angle osteosynthesis
    Herren, C.
    Ringe, M. J.
    Rietkoetter, U.
    Sobottke, R.
    Siewe, J.
    Graf, M.
    UNFALLCHIRURG, 2014, 117 (08): : 740 - 746
  • [10] A new osteosynthesis device for the treatment of proximal humerus fractures. Description of the technique and preliminary results.
    Russo R.
    Lombardi L.V.
    Ciccarelli M.
    Giudice G.
    Cautiero F.
    La Chirurgia degli Organi di Movimento, 2008, 91 (1): : 27 - 34