CRYSTALLINE MICROCOLUMNAR CsI:Tl FILMS FOR USE IN GAMMA-RAY IMAGING WITH DEPTH-OF-INTERACTION SENSITIVITY

被引:0
|
作者
Bhandari, Harish
Barber, H. Bradford
Dumas, Christopher
Kudrolli, Haris
Miller, Brian W.
Chac, George T. L.
Han, Ling
Nagarkar, Vivek V.
机构
来源
MEDICAL APPLICATIONS OF RADIATION DETECTORS II | 2012年 / 8508卷
关键词
DETECTOR; DESIGN;
D O I
10.1117/12.966196
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Columnar, amorphous CsI:Tl scintillators are attractive for biomedical imaging applications because they allow high spatial resolution with EMCCD detectors and BazookaSPECT. But these scintillators have a serious practical limitation, they are not useful in thickness larger than 0.5 mm, because of attenuation; this means that detection efficiencies are very poor for >= 100 keV gamma rays. The development of a new crystalline microcolumnar scintillator (CMS) of CsI:Tl is described. CMS CsI:Tl has high density and greatly improved light transmission properties. CMS films were prepared in three thicknesses (0.5 mm, 1.0 mm and 4.0 mm), and test results for these films are described. The light yield and energy resolution for 0.5 mm, CMS CsI:Tl films was equivalent to that of conventional bulk CsI:Tl scintillators; while some light attenuation was seen in 4 mm-thick CMS CsI:Tl samples, useable photopeaks were obtained at 122 keV. The spatial resolution measured for the 0.5 mm and 1.0 mm films in a BazookaSPECT system was excellent, 150-200 mu m. Imaging tests with the 4 mm-thick CMS CsI:Tl films in a BazookaSPECT system with 662 keV gamma rays showed progressive broadening of the signal clusters on the CCD camera with depth of interaction (DOI), indicating that DOI determination should be possible with these detectors, i.e. 3D detector operation. Future planned investigations are described.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Fabrication of X-ray/gamma-ray detector by growth of microcolumnar CsI:Tl onto silicon photomultipliers
    Sabet, Hamid
    Bhandari, Harish B.
    Kudrolli, Haris
    Nagarkar, Vivek V.
    PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON TECHNOLOGY AND INSTRUMENTATION IN PARTICLE PHYSICS (TIPP 2011), 2012, 37 : 1523 - 1530
  • [2] Gamma-ray imaging with a Si/CsI(Tl) compton detector
    Hoover, A. S.
    Sullivan, J. P.
    Baird, B.
    Brumby, S. P.
    Kippen, R. M.
    McCluskey, C. W.
    Rawool-Sullivan, M. W.
    Sorensen, E. B.
    APPLIED RADIATION AND ISOTOPES, 2006, 64 (12) : 1648 - 1654
  • [3] THE OPTIMIZATION OF SMALL CSI(TL) GAMMA-RAY DETECTORS
    BIRD, AJ
    CARTER, T
    DEAN, AJ
    RAMSDEN, D
    SWINYARD, BM
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) : 395 - 399
  • [4] Real time depth-of-interaction correction for coded-aperture, gamma-ray images
    Ziock, K. P.
    Blackston, M. A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 916 : 56 - 65
  • [5] Maximum likelihood positioning for gamma-ray imaging detectors with depth of interaction measurement
    Lerche, Ch. W.
    Ros, A.
    Monzo, J. M.
    Aliaga, R. J.
    Ferrando, N.
    Martinez, J. D.
    Herrero, V.
    Esteve, R.
    Gadea, R.
    Colom, R. J.
    Toledo, J.
    Mateo, F.
    Sebastia, A.
    Sanchez, F.
    Benlloch, J. M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 604 (1-2): : 359 - 362
  • [6] TEMPERATURE-DEPENDENCE OF CSI(TL) GAMMA-RAY EXCITED SCINTILLATION CHARACTERISTICS
    VALENTINE, JD
    MOSES, WW
    DERENZO, SE
    WEHE, DK
    KNOLL, GF
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 325 (1-2): : 147 - 157
  • [7] Separation of gamma-ray and neutron events with CsI(Tl) pulse shape analysis
    Ashida, Y.
    Nagata, H.
    Koshio, Y.
    Nakaya, T.
    Wendell, R.
    PROGRESS OF THEORETICAL AND EXPERIMENTAL PHYSICS, 2018, 2018 (04):
  • [8] Performance of Indigenously Developed CsI(Tl)-Photodiode Detector for Gamma-ray Spectroscopy
    Singh, S. G.
    Singh, Arvind
    Topkar, Anita
    Gadkari, S. C.
    SOLID STATE PHYSICS: PROCEEDINGS OF THE 55TH DAE SOLID STATE PHYSICS SYMPOSIUM 2010, PTS A AND B, 2011, 1349 : 481 - +
  • [9] CsI(Tl) micro-pixel scintillation array for ultra-high resolution gamma-ray imaging
    Cinti, M. N.
    Scafe, R.
    Pellegrini, R.
    Trotta, C.
    Bennati, P.
    Ridolfi, S.
    Lanconelli, Nico
    Montani, L.
    Cusanno, F.
    Garibaldi, F.
    Telfer, J.
    Pani, R.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (03) : 469 - 474
  • [10] CsI(Tl) micro-pixel scintillation array for ultra-high resolution gamma-ray imaging
    Cinti, MN
    Scafè, R
    Pellegrini, R
    Trotta, C
    Bennati, P
    Ridolfi, S
    Montani, L
    Cusanno, F
    Garibaldi, F
    Telfer, J
    Pani, R
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2371 - 2375