Comparison of dynamic changes in aortic diameter during the cardiac cycle measured by computed tomography angiography and transthoracic echocardiography

被引:11
|
作者
Huang, Jian [1 ,2 ]
Wang, Yongsheng [1 ]
Lin, Lin [3 ]
Li, Zhibin [4 ]
Shan, Zhonggui [2 ]
Zheng, Shaoyi [1 ]
机构
[1] Southern Med Univ, Nanfang Hosp, Dept Cardiovasc Surg, Sch Clin Med 1, 1023 S Shatai Rd, Guangzhou 510515, Guangdong, Peoples R China
[2] Xiamen Univ, Affiliated Hosp 1, Dept Cardiovasc Surg, Xiamen, Peoples R China
[3] Xiamen Univ, Affiliated Hosp 1, Cent Lab, Xiamen, Peoples R China
[4] Xiamen Univ, Affiliated Hosp 1, Epidemiol Res Unit, Xiamen, Peoples R China
关键词
Aortic diameter; Transthoracic echocardiography; Computed tomography angiography; Intraoperative ultrasound; Dynamic change; ASSOCIATION; DISSECTION; SOCIETY; IMPACT;
D O I
10.1016/j.jvs.2018.07.083
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: This study aimed to examine the relationship between dynamic changes in aortic diameter and corresponding measurement methods. Methods: Consecutive adult (nonaneurysmal) patients being surgically treated for heart disease (mean age, 51 +/- 11 years; range, 29-76 years; N = 25) were included in this study. All patients underwent transthoracic echocardiography (TTE), computed tomography angiography (CTA), and intraoperative ultrasound (IOUS). Anteroposterior diameters were measured at 1 cm above the junction of the aortic sinus, the proximal 1 cm of the innominate artery, and the midpoint of the two. Results: The average diameter of the proximal ascending aorta in systole/diastole measured by IOUS was 32.07 +/- 2.03/30.27 +/- 2.05 mm (paired t-test: difference, 1.80 +/- 0.46 mm; P < .001). The average diameters of the proximal ascending aorta measured by nonelectrocardiography-gated CTA and TTE were 31.45 +/- 1.97 mm and 29.7 +/- 1.84 mm, respectively. The average diameter of the mid and distal ascending aorta in systole/diastole measured by IOUS was 32.35 +/- 1.95/30.57 +/- 1.94 mm (paired t-test: difference, 1.78 +/- 0.44 mm; P < .001) and 32.32 +/- 1.92/30.67 +/- 1.90 mm (paired t-test: difference, 1.65 +/- 0.42 mm; P < .001), respectively. The average diameter of themid and distal ascending aorta measured by CTA was 31.74 +/- 1.92 mm and 31.59 +/- 1.96 mm, respectively. At each location, the difference in the aortic diameter between systole and diastole was statistically significant (all P values < .001; paired t-test). The minimum and maximum changes in the diameter between systole and diastole were 0.90 mm and 2.70 mm. In all, 96% (24/25) of the average diameters derived from IOUS and CTA at the three locations were within the concordance limit in systole, and 92% to 100% (23/25 to 25/25) were within the concordance limit in diastole. The average diameters derived from IOUS and TTE images of the proximal ascending aorta were within the bounds of the concordance limit 92% (23/25) of the time in systole and 100% (25/25) of the time in diastole. The average diameters derived from CTA and TTE images of the proximal ascending aorta were within the bounds of the concordance limit 88%(22/25) of the time. Pearson correlation coefficients between these groups ranged from 0.905 to 0.982 (all P values < . 01). Conclusions: The ascending aorta diameters measured by nonelectrocardiography-gated CTA and TTE were consistent with the IOUS measurements.
引用
收藏
页码:1538 / 1544
页数:7
相关论文
共 50 条
  • [1] Dual-Source Computed Tomography Angiography in Aortic Stenosis: Comparison with Transthoracic Echocardiography
    Yaakup, Nur Adura
    Phuah, Hooi Fang
    Aziz, Yang Faridah Abdul
    Abidin, Imran Zainal
    Sun, Zhonghua
    Ng, Kwan Hoong
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2014, 4 (05) : 749 - 755
  • [2] Comparison of cardiac measurements by multi-detector computed tomography angiography and transthoracic echocardiography in English bulldogs
    Hostnik, E. T.
    Scansen, B. A.
    Habing, A. M.
    Chiappone, G. A.
    Layman, R. R.
    White, R. D.
    JOURNAL OF VETERINARY CARDIOLOGY, 2017, 19 (06) : 480 - 491
  • [3] MULTIMODALITY IMAGING OF THE AORTIC ROOT: COMPARISON OF TRANSTHORACIC ECHOCARDIOGRAPHY WITH MULTIDETECTOR GATED COMPUTED TOMOGRAPHY
    Farag, A.
    Tsang, J.
    Wallace, K.
    Lytwyn, M.
    Zeglinski, M.
    Bohonis, S.
    Walker, J. R.
    Tam, J. W.
    Strzelczyk, J.
    Jassal, D. S.
    CANADIAN JOURNAL OF CARDIOLOGY, 2011, 27 (05) : S274 - S275
  • [4] Multimodality Imaging of Aortic Dimensions: Comparison of Transthoracic Echocardiography with Multidetector Row Computed Tomography
    Tsang, James F.
    Lytwyn, Matthew
    Farag, Ashraf
    Zeglinski, Matthew
    Wallace, Kerrett
    daSilva, Megan
    Bohonis, Sheena
    Walker, Jonathan R.
    Tam, James W.
    Strzelczyk, Jacek
    Jassal, Davinder S.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2012, 29 (06): : 735 - 741
  • [5] Dynamic aortic changes during the cardiac cycle in patients with aortic valve disease analyzed by computed tomography combined with PhyZiodynamics software
    Togo Norimatsu
    Nobuo Iguchi
    Mitsuaki Isobe
    The International Journal of Cardiovascular Imaging, 2023, 39 : 2073 - 2082
  • [6] Dynamic aortic changes during the cardiac cycle in patients with aortic valve disease analyzed by computed tomography combined with PhyZiodynamics software
    Norimatsu, Togo
    Iguchi, Nobuo
    Isobe, Mitsuaki
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2023, 39 (10): : 2073 - 2082
  • [7] Comparison of Computed Tomography Angiography and Transesophageal Echocardiography for Evaluating Aortic Arch Disease
    Barazangi, Nobl
    Wintermark, Max
    Lease, Katy
    Rao, Rajni
    Smith, Wade
    Josephson, S. Andrew
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2011, 20 (05): : 436 - 442
  • [8] Aortic valve area assessed with 320-detector computed tomography: comparison with transthoracic echocardiography
    Larsen, Linnea Hornbech
    Kofoed, Klaus Fuglsang
    Carstensen, Helle Gervig
    Mejdahl, Mads Rams
    Andersen, Mads Jonsson
    Kjaergaard, Jesper
    Nielsen, Olav Wendelboe
    Kober, Lars
    Mogelvang, Rasmus
    Hassager, Christian
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 (01): : 165 - 173
  • [9] Aortic valve area assessed with 320-detector computed tomography: comparison with transthoracic echocardiography
    Linnea Hornbech Larsen
    Klaus Fuglsang Kofoed
    Helle Gervig Carstensen
    Mads Rams Mejdahl
    Mads Jønsson Andersen
    Jesper Kjaergaard
    Olav Wendelboe Nielsen
    Lars Køber
    Rasmus Møgelvang
    Christian Hassager
    The International Journal of Cardiovascular Imaging, 2014, 30 : 165 - 173
  • [10] Morphological assessment of the aortic valve using coronary computed tomography angiography, cardiovascular magnetic resonance, and transthoracic echocardiography: comparison with intraoperative findings
    Seung Choul Lee
    Sung Min Ko
    Meong Gun Song
    Je Kyoun Shin
    Hyun Keun Chee
    Hweung Kon Hwang
    The International Journal of Cardiovascular Imaging, 2012, 28 : 33 - 44