Estimate of nocturnal blood pressure and detection of non-dippers based on clinical or ambulatory monitoring in the inpatient setting

被引:6
|
作者
Xu, Tan [1 ]
Zhang, Yongqing [2 ]
Tan, Xuerui [1 ]
机构
[1] Shantou Univ, Coll Med, Affiliated Hosp 1, Dept Cardiol, Shantou 515041, Guangdong, Peoples R China
[2] Peoples Hosp SanYan, Dept Cardiol, Sanyan 572000, Hainan, Peoples R China
来源
关键词
Nocturnal blood pressure; Ambulatory blood pressure monitoring; Hypertension; Non-dipper; SELF-MEASUREMENT; PROGNOSTIC VALUE; HYPERTENSION; HOME; PROFILE; EVENTS;
D O I
10.1186/1471-2261-13-37
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Ambulatory blood pressure monitoring is regarded as the gold standard for monitoring nocturnal blood pressure (NBP) and is usually performed out of office. Currently, a novel method for monitoring NBP is indispensible in the inpatient setting. The widely used manual BP monitoring procedure has the potential to monitor NBP in the hospital setting. The feasibility and accuracy of manual sphygmomanometer to monitor NBP has not been explored widely. Methods: A cross-sectional study was conducted at the cardiology department of a university-affiliated hospital to study patients with mild-to-moderate essential hypertension. One hundred and fifty-five patients were recruited to compare BP derived from a manual device and ambulatory BP monitoring (ABPM). The manual BP measurement was performed six times at 22: 00, 02: 00, 06: 00, 10: 00, 14: 00 and 18: 00 h. The measurements at 22: 00, 02: 00 and 06: 00 h were defined as night-time and the others as daytime. ABPM was programmed to measure at 30-min intervals between measurements. Results: All-day, daytime and night-time BP did not differ significantly from 24-h ambulatory systolic BP [all-day mean difference -0.52 +/- 4.67 mmHg, 95% confidence interval (CI) -1.26 to 0.22, P= 0.168; daytime mean difference 0.24 +/- 5.45 mmHg, 95% CI -0.62 to 1.11, P= 0.580; night-time mean difference 0.30 +/- 7.22 mmHg, 95% CI -0.84 to 1.45, P= 0.601) rather than diastolic BP. There was a strong correlation between clinical and ambulatory BP for both systolic and diastolic BP. On the basis of ABPM, 101 (65%) patients were classified as non-dippers, compared with 106 (68%) by manual sphygmomanometer (P< 0.001). Conclusions: Traditional manual sphygmomanometer provides similar daytime and night-time systolic BP measurements in hospital. Moreover, the detection of non-dippers by manual methods is in good agreement with 24-h ABPM. Further studies are required to confirm the clinical relevance of these findings by comparing the association of NBP in the hospital ward assessed by manual monitoring with preclinical organ damage and cardiovascular and cerebrovascular outcomes.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Estimate of nocturnal blood pressure and detection of non-dippers based on clinical or ambulatory monitoring in the inpatient setting
    Tan Xu
    Yongqing Zhang
    Xuerui Tan
    BMC Cardiovascular Disorders, 13
  • [2] Ambulatory blood pressure monitoring: dippers compared with non-dippers
    White, WB
    BLOOD PRESSURE MONITORING, 2000, 5 : S17 - S23
  • [3] Assessment of the Diurnal Blood Pressure Profile and Detection of Non-Dippers Based on Home or Ambulatory Monitoring
    Stergiou, George S.
    Nasothimiou, Efthimia G.
    Destounis, Antonios
    Poulidakis, Emanouel
    Evagelou, Irini
    Tzamouranis, Dimitrios
    AMERICAN JOURNAL OF HYPERTENSION, 2012, 25 (09) : 974 - 978
  • [4] Heart rate variability in dippers and in non-dippers investigated by ambulatory blood pressure monitoring
    Simonyi, G.
    Bedros, J. R.
    Medvegy, M.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2010, 12 (0A) : S19 - S20
  • [5] Reproducibility of ambulatory blood pressure measurement in renal hypertension - Dippers and non-dippers
    Liebisch, B
    Kletzmayr, J
    Webber, F
    Schneider, B
    TIME-DEPENDENT STRUCTURE AND CONTROL OF ARTERIAL BLOOD PRESSURE, 1996, 783 : 333 - 334
  • [6] Reproducibility of nocturnal blood pressure reduction rate and the prevalence of "non-dippers" using 48-hour ambulatory blood pressure monitoring in patients with essential hypertension
    Mochizuki, Y
    Okutani, M
    Iwasaki, K
    Kohno, I
    Mochizuki, S
    Umetani, K
    Ishii, H
    Ijiri, H
    Komori, S
    Tamura, K
    TIME-DEPENDENT STRUCTURE AND CONTROL OF ARTERIAL BLOOD PRESSURE, 1996, 783 : 330 - 332
  • [7] PULSE PRESSURE IN DIPPERS AND IN NON DIPPERS MEASURED BY AMBULATORY BLOOD PRESSURE MONITORING
    Simonyi, G.
    Bedros, J. R.
    Medvegy, M.
    Varkonyi, M.
    Metz, E.
    Kardos, M.
    Toemlo, R.
    Koncz, J.
    Peter, E.
    Kleh-Kovacs, L.
    Mueller, G.
    JOURNAL OF HYPERTENSION, 2009, 27 : S199 - S200
  • [8] Sleep and blood pressure: Spontaneous baroreflex sensitivity in dippers and non-dippers
    Vaile, JC
    Stallard, TJ
    AlAni, M
    Jordan, PJ
    Townend, JN
    Littler, WA
    JOURNAL OF HYPERTENSION, 1996, 14 (12) : 1427 - 1432
  • [9] Treating Hypertensive Non-Dippers: Additional Benefit from Nocturnal Blood Pressure Reduction?
    Giuseppe Schillaci
    Massimo R. Mannarino
    Matteo Pirro
    Cardiovascular Drugs and Therapy, 2005, 19 : 169 - 171
  • [10] Ambulatory blood pressure in cerebral infarct patients treated with the ACE inhibitor - Comparison between dippers and non-dippers
    Yasumasa, Y
    Yamamoto, Y
    Oiwa, K
    Hayashi, M
    JOURNAL OF HYPERTENSION, 2004, 22 : S134 - S134